CVE-2026-15203 (GCVE-0-2026-15203)
Vulnerability from cvelistv5
Published
2026-08-26 05:36
Modified
2026-08-26 14:58
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-1191 - On-Chip debug and test interface with improper access control
Summary
Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Danfoss | iC7-Automation SP |
Version: 0 < |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-15203",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-26T14:55:58.163499Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T14:58:01.137Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "iC7-Automation SP",
"vendor": "Danfoss",
"versions": [
{
"lessThanOrEqual": "2025.3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "iC7-Marine",
"vendor": "Danfoss",
"versions": [
{
"lessThanOrEqual": "2025.8.19",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "iC7-Hybrid",
"vendor": "Danfoss",
"versions": [
{
"lessThanOrEqual": "2025.10.300845",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eImproper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms\u003cbr\u003e\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms"
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1191",
"description": "CWE-1191 On-Chip debug and test interface with improper access control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T05:36:02.006Z",
"orgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"shortName": "Danfoss"
},
"references": [
{
"tags": [
"patch"
],
"url": "https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip"
},
{
"tags": [
"patch"
],
"url": "https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip"
},
{
"tags": [
"patch"
],
"url": "https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cul\u003e\u003cli\u003eiC7-Automation SP:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\" title=\"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\"\u003ehttps://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.2.5-26A)\u003c/li\u003e\u003cli\u003eiC7-Marine:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\" title=\"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\"\u003ehttps://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.6.30-GR4.4)\u003c/li\u003e\u003cli\u003eiC7-Hybrid:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\" title=\"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\"\u003ehttps://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.7.2-GR4.5)\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e"
}
],
"value": "* iC7-Automation SP:\u00a0 https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip \u00a0(Release\u00a02026.2.5-26A)\n * iC7-Marine:\u00a0 https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip \u00a0(Release\u00a02026.6.30-GR4.4)\n * iC7-Hybrid:\u00a0 https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip \u00a0(Release\u00a02026.7.2-GR4.5)"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"assignerShortName": "Danfoss",
"cveId": "CVE-2026-15203",
"datePublished": "2026-08-26T05:36:02.006Z",
"dateReserved": "2026-07-09T06:41:49.174Z",
"dateUpdated": "2026-08-26T14:58:01.137Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-15203\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-08-26T14:55:58.163499Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-08-26T14:57:57.269Z\"}}], \"cna\": {\"title\": \"Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software\", \"source\": {\"discovery\": \"INTERNAL\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 9.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"LOW\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"LOW\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"LOW\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Danfoss\", \"product\": \"iC7-Automation SP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"2025.3.3\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Danfoss\", \"product\": \"iC7-Marine\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"2025.8.19\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Danfoss\", \"product\": \"iC7-Hybrid\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"2025.10.300845\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"* iC7-Automation SP:\\u00a0 https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip \\u00a0(Release\\u00a02026.2.5-26A)\\n * iC7-Marine:\\u00a0 https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip \\u00a0(Release\\u00a02026.6.30-GR4.4)\\n * iC7-Hybrid:\\u00a0 https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip \\u00a0(Release\\u00a02026.7.2-GR4.5)\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cdiv\u003e\u003cul\u003e\u003cli\u003eiC7-Automation SP:\u0026nbsp;\u003ca href=\\\"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\\\" title=\\\"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\\\"\u003ehttps://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.2.5-26A)\u003c/li\u003e\u003cli\u003eiC7-Marine:\u0026nbsp;\u003ca href=\\\"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\\\" title=\\\"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\\\"\u003ehttps://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.6.30-GR4.4)\u003c/li\u003e\u003cli\u003eiC7-Hybrid:\u0026nbsp;\u003ca href=\\\"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\\\" title=\\\"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\\\"\u003ehttps://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.7.2-GR4.5)\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\", \"tags\": [\"patch\"]}, {\"url\": \"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\", \"tags\": [\"patch\"]}, {\"url\": \"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\", \"tags\": [\"patch\"]}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.4\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cdiv\u003e\u003cdiv\u003eImproper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms\u003cbr\u003e\u003c/div\u003e\u003c/div\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1191\", \"description\": \"CWE-1191 On-Chip debug and test interface with improper access control\"}]}], \"providerMetadata\": {\"orgId\": \"d7ff35af-cf88-454c-bab9-af60602f10f8\", \"shortName\": \"Danfoss\", \"dateUpdated\": \"2026-08-26T05:36:02.006Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-15203\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-08-26T14:58:01.137Z\", \"dateReserved\": \"2026-07-09T06:41:49.174Z\", \"assignerOrgId\": \"d7ff35af-cf88-454c-bab9-af60602f10f8\", \"datePublished\": \"2026-08-26T05:36:02.006Z\", \"assignerShortName\": \"Danfoss\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…