Refine your search
14 vulnerabilities found for by Danfoss
CVE-2026-15203 (GCVE-0-2026-15203)
Vulnerability from cvelistv5
Published
2026-08-26 05:36
Modified
2026-08-26 14:58
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-1191 - On-Chip debug and test interface with improper access control
Summary
Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Danfoss | iC7-Automation SP |
Version: 0 < |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-15203",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-26T14:55:58.163499Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T14:58:01.137Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "iC7-Automation SP",
"vendor": "Danfoss",
"versions": [
{
"lessThanOrEqual": "2025.3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "iC7-Marine",
"vendor": "Danfoss",
"versions": [
{
"lessThanOrEqual": "2025.8.19",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "iC7-Hybrid",
"vendor": "Danfoss",
"versions": [
{
"lessThanOrEqual": "2025.10.300845",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eImproper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms\u003cbr\u003e\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms"
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1191",
"description": "CWE-1191 On-Chip debug and test interface with improper access control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T05:36:02.006Z",
"orgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"shortName": "Danfoss"
},
"references": [
{
"tags": [
"patch"
],
"url": "https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip"
},
{
"tags": [
"patch"
],
"url": "https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip"
},
{
"tags": [
"patch"
],
"url": "https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cul\u003e\u003cli\u003eiC7-Automation SP:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\" title=\"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\"\u003ehttps://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.2.5-26A)\u003c/li\u003e\u003cli\u003eiC7-Marine:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\" title=\"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\"\u003ehttps://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.6.30-GR4.4)\u003c/li\u003e\u003cli\u003eiC7-Hybrid:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\" title=\"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\"\u003ehttps://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.7.2-GR4.5)\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e"
}
],
"value": "* iC7-Automation SP:\u00a0 https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip \u00a0(Release\u00a02026.2.5-26A)\n * iC7-Marine:\u00a0 https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip \u00a0(Release\u00a02026.6.30-GR4.4)\n * iC7-Hybrid:\u00a0 https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip \u00a0(Release\u00a02026.7.2-GR4.5)"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"assignerShortName": "Danfoss",
"cveId": "CVE-2026-15203",
"datePublished": "2026-08-26T05:36:02.006Z",
"dateReserved": "2026-07-09T06:41:49.174Z",
"dateUpdated": "2026-08-26T14:58:01.137Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41452 (GCVE-0-2025-41452)
Vulnerability from cvelistv5
Published
2025-08-22 02:40
Modified
2025-08-22 10:52
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-15 - External Control of System or Configuration Setting
Summary
Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, which could allow for a denial of service attack induced by improper handling of exceptional conditions
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Danfoss | AK-SM8xxA Series |
Version: 0 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41452",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-22T10:52:01.090719Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T10:52:36.122Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-SM8xxA Series",
"vendor": "Danfoss",
"versions": [
{
"lessThan": "4.3.1",
"status": "affected",
"version": "0",
"versionType": "cpe"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, which\u0026nbsp;could allow for a denial of service attack induced by improper handling of exceptional conditions"
}
],
"value": "Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, which\u00a0could allow for a denial of service attack induced by improper handling of exceptional conditions"
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:A/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-15",
"description": "CWE-15: External Control of System or Configuration Setting",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T02:40:53.563Z",
"orgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"shortName": "Danfoss"
},
"references": [
{
"url": "https://www.danfoss.com/en/service-and-support/downloads/dcs/adap-kool-software/ak-sm-800a/#tab-overview"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Post auth nginx configuration injection in Danfoss AK-SM8xxA Series",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"assignerShortName": "Danfoss",
"cveId": "CVE-2025-41452",
"datePublished": "2025-08-22T02:40:53.563Z",
"dateReserved": "2025-04-16T10:32:42.818Z",
"dateUpdated": "2025-08-22T10:52:36.122Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41451 (GCVE-0-2025-41451)
Vulnerability from cvelistv5
Published
2025-08-22 02:40
Modified
2025-08-22 11:25
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Summary
Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command ('Command Injection') in Danfoss AK-SM8xxA Series prior to version 4.3.1, leading to a potential post-authenticated remote code execution on an attacked system.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Danfoss | AK-SM8xxA Series |
Version: 0 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41451",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-22T10:59:49.161150Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T11:25:28.640Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-SM8xxA Series",
"vendor": "Danfoss",
"versions": [
{
"lessThan": "4.3.1",
"status": "affected",
"version": "0",
"versionType": "cpe"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command (\u0027Command Injection\u0027) in Danfoss AK-SM8xxA Series\u0026nbsp;prior to version 4.3.1, leading to a potential post-authenticated remote code execution on an attacked system."
}
],
"value": "Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command (\u0027Command Injection\u0027) in Danfoss AK-SM8xxA Series\u00a0prior to version 4.3.1, leading to a potential post-authenticated remote code execution on an attacked system."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T02:40:46.216Z",
"orgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"shortName": "Danfoss"
},
"references": [
{
"url": "https://www.danfoss.com/en/service-and-support/downloads/dcs/adap-kool-software/ak-sm-800a/#tab-overview"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Post-Authentication OS Command Injection RCE in Danfoss AK-SM8xxA Series",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"assignerShortName": "Danfoss",
"cveId": "CVE-2025-41451",
"datePublished": "2025-08-22T02:40:46.216Z",
"dateReserved": "2025-04-16T10:32:42.818Z",
"dateUpdated": "2025-08-22T11:25:28.640Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41450 (GCVE-0-2025-41450)
Vulnerability from cvelistv5
Published
2025-05-08 09:41
Modified
2025-08-27 07:14
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-305 - Authentication Bypass by Primary Weakness
Summary
Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Danfoss | AK-SM 8xxA Series |
Version: 0 < 4.2 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41450",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T13:51:39.737731Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-08T13:52:31.326Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-SM 8xxA Series",
"vendor": "Danfoss",
"versions": [
{
"lessThan": "4.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-05-08T09:40:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Authentication vulnerability in Danfoss AKSM8xxA Series.\u003cp\u003eThis issue affects Danfoss AK-SM 8xxA Series prior to version 4.2\u003c/p\u003e"
}
],
"value": "Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-305",
"description": "CWE-305: Authentication Bypass by Primary Weakness",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T07:14:14.846Z",
"orgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"shortName": "Danfoss"
},
"references": [
{
"url": "https://www.danfoss.com/en/service-and-support/coordinated-vulnerability-disclosure/danfoss-security-advisories/dsa-2025-03-01/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authentication bypass with privileged access in Danfoss AK-SM 8xxA Series prior to version 4.2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"assignerShortName": "Danfoss",
"cveId": "CVE-2025-41450",
"datePublished": "2025-05-08T09:41:20.881Z",
"dateReserved": "2025-04-16T10:32:42.818Z",
"dateUpdated": "2025-08-27T07:14:14.846Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25913 (GCVE-0-2023-25913)
Vulnerability from cvelistv5
Published
2023-08-21 20:30
Modified
2025-01-09 07:56
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
Because of an authentication flaw an attacker would be capable of generating a web report that discloses sensitive information such as internal IP addresses, usernames, store names and other sensitive information.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:32:12.759Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/CVE-2023-25913"
},
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/DIVD-2023-00025"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-25913",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-02T15:07:21.982541Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-02T15:15:26.754Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-SM800A",
"vendor": "Danfoss",
"versions": [
{
"status": "affected",
"version": "\u003c 3.3"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Jony Schats (HackDefense)"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Stan Plasmeijer (HackDefense)"
},
{
"lang": "en",
"type": "analyst",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Max van der Horst (DIVD)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Because of an authentication flaw an attacker would be capable of generating a web report that discloses sensitive information such as internal IP addresses, usernames, store names and other sensitive information."
}
],
"value": "Because of an authentication flaw an attacker would be capable of generating a web report that discloses sensitive information such as internal IP addresses, usernames, store names and other sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T07:56:41.147Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2023-25913"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2023-00025"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Authentication Bypass in Danfoss AK-SM800A",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to the latest patch, which is version 3.3."
}
],
"value": "Upgrade to the latest patch, which is version 3.3."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2023-25913",
"datePublished": "2023-08-21T20:30:03.854Z",
"dateReserved": "2023-02-16T14:22:41.966Z",
"dateUpdated": "2025-01-09T07:56:41.147Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25914 (GCVE-0-2023-25914)
Vulnerability from cvelistv5
Published
2023-08-21 20:30
Modified
2025-07-19 05:15
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
Due to improper restriction, authenticated attackers could retrieve and read system files of the underlying server through the XML interface. The information that can be read can lead to a full system compromise.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:32:12.736Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/CVE-2023-25914"
},
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/DIVD-2023-00025"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:danfoss:ak-sm_800a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ak-sm_800a",
"vendor": "danfoss",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-25914",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-02T14:46:32.023415Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-02T14:46:47.607Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-SM800A",
"vendor": "Danfoss",
"versions": [
{
"status": "affected",
"version": "\u003c 3.3"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Synacktiv"
},
{
"lang": "en",
"type": "analyst",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Max van der Horst (DIVD)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Due to improper restriction, authenticated attackers could retrieve and read system files of the underlying server through the XML interface. The information that can be read can lead to a full system compromise."
}
],
"value": "Due to improper restriction, authenticated attackers could retrieve and read system files of the underlying server through the XML interface. The information that can be read can lead to a full system compromise."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-19T05:15:44.063Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2023-25914"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2023-00025"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Authneticated Path Traversal in Danfoss AK-SM800A",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to the latest patch, which is version 3.3."
}
],
"value": "Upgrade to the latest patch, which is version 3.3."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2023-25914",
"datePublished": "2023-08-21T20:30:03.122Z",
"dateReserved": "2023-02-16T14:22:41.966Z",
"dateUpdated": "2025-07-19T05:15:44.063Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25915 (GCVE-0-2023-25915)
Vulnerability from cvelistv5
Published
2023-08-21 20:30
Modified
2025-01-09 07:56
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-20 - Improper Input Validation
Summary
Due to improper input validation, an authenticated remote attacker could execute arbitrary commands on the target system.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:32:12.619Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/CVE-2023-25915"
},
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/DIVD-2023-00025"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:danfoss:ak-sm_800a_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ak-sm_800a_firmware",
"vendor": "danfoss",
"versions": [
{
"lessThanOrEqual": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-25915",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-03T19:42:57.224088Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-03T19:49:03.078Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-SM800A",
"vendor": "Danfoss",
"versions": [
{
"status": "affected",
"version": "\u003c 3.3"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Synacktiv"
},
{
"lang": "en",
"type": "analyst",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Max van der Horst (DIVD)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Due to improper input validation, an authenticated remote attacker could execute arbitrary commands on the target system."
}
],
"value": "Due to improper input validation, an authenticated remote attacker could execute arbitrary commands on the target system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T07:56:40.947Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2023-25915"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2023-00025"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Authenticated Remote Command Execution in Danfoss AK-SM800A",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to the latest patch, which is version 3.3."
}
],
"value": "Upgrade to the latest patch, which is version 3.3."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2023-25915",
"datePublished": "2023-08-21T20:30:02.375Z",
"dateReserved": "2023-02-16T14:22:41.966Z",
"dateUpdated": "2025-01-09T07:56:40.947Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25911 (GCVE-0-2023-25911)
Vulnerability from cvelistv5
Published
2023-06-11 13:17
Modified
2025-01-09 07:56
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Summary
The Danfoss AK-EM100 web applications allow for an authenticated user to perform OS command injection through the web application parameters.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:32:12.743Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://divd.nl/cves/CVE-2023-25911"
},
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-25911",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T17:46:43.581155Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T17:46:53.396Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-EM100",
"vendor": "Danfoss",
"versions": [
{
"status": "affected",
"version": "\u003c 2.2.0.12"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Jony Schats (Hackdefense)"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Stan Plasmeijer (Hackdefense)"
},
{
"lang": "en",
"type": "analyst",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Max van der Horst (DIVD)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Danfoss AK-EM100 web applications allow for an authenticated user to perform OS command injection through the web application parameters."
}
],
"value": "The Danfoss AK-EM100 web applications allow for an authenticated user to perform OS command injection through the web application parameters."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T07:56:42.059Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2023-25911/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Authenticated OS Command Injection in Danfoss AK-EM100",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2023-25911",
"datePublished": "2023-06-11T13:17:02.850Z",
"dateReserved": "2023-02-16T14:22:41.966Z",
"dateUpdated": "2025-01-09T07:56:42.059Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22583 (GCVE-0-2023-22583)
Vulnerability from cvelistv5
Published
2023-06-11 13:17
Modified
2025-01-09 07:56
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
The Danfoss AK-EM100 web forms allow for SQL injection in the login forms.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:49.090Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://divd.nl/cves/CVE-2023-22583"
},
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22583",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T17:52:35.580689Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T17:52:47.814Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-EM100",
"vendor": "Danfoss",
"versions": [
{
"status": "affected",
"version": "\u003c 2.2.0.12"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Jony Schats (Hackdefense)"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Stan Plasmeijer (Hackdefense)"
},
{
"lang": "en",
"type": "analyst",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Max van der Horst (DIVD)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Danfoss AK-EM100 web forms allow for SQL injection in the login forms."
}
],
"value": "The Danfoss AK-EM100 web forms allow for SQL injection in the login forms."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T07:56:41.855Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2023-22583/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "SQL Injection in Danfoss AK-EM100",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2023-22583",
"datePublished": "2023-06-11T13:17:02.674Z",
"dateReserved": "2023-01-03T07:33:48.702Z",
"dateUpdated": "2025-01-09T07:56:41.855Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22582 (GCVE-0-2023-22582)
Vulnerability from cvelistv5
Published
2023-06-11 13:17
Modified
2025-01-09 07:56
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:49.099Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://divd.nl/cves/CVE-2023-22582"
},
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22582",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T17:32:06.603895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T17:32:20.831Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-EM100",
"vendor": "Danfoss",
"versions": [
{
"status": "affected",
"version": "\u003c 2.2.0.12"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Jony Schats (Hackdefense)"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Stan Plasmeijer (Hackdefense)"
},
{
"lang": "en",
"type": "analyst",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Max van der Horst (DIVD)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting."
}
],
"value": "The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T07:56:41.506Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2023-22582/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Reflected Cross-Site Scripting in Danfoss AK-EM100",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2023-22582",
"datePublished": "2023-06-11T13:17:02.415Z",
"dateReserved": "2023-01-03T07:33:48.702Z",
"dateUpdated": "2025-01-09T07:56:41.506Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22584 (GCVE-0-2023-22584)
Vulnerability from cvelistv5
Published
2023-06-11 13:17
Modified
2025-01-09 07:56
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Summary
The Danfoss AK-EM100 stores login credentials in cleartext.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:49.105Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://divd.nl/cves/CVE-2023-22584"
},
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22584",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T17:53:15.408844Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T17:53:25.027Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-EM100",
"vendor": "Danfoss",
"versions": [
{
"status": "affected",
"version": "\u003c 2.2.0.12"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Jony Schats (Hackdefense)"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Stan Plasmeijer (Hackdefense)"
},
{
"lang": "en",
"type": "analyst",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Max van der Horst (DIVD)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Danfoss AK-EM100 stores login credentials in cleartext."
}
],
"value": "The Danfoss AK-EM100 stores login credentials in cleartext."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T07:56:42.422Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2023-22584/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Cleartext credentials in Danfoss AK-EM100",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2023-22584",
"datePublished": "2023-06-11T13:17:01.948Z",
"dateReserved": "2023-01-03T07:33:48.702Z",
"dateUpdated": "2025-01-09T07:56:42.422Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22585 (GCVE-0-2023-22585)
Vulnerability from cvelistv5
Published
2023-06-11 13:17
Modified
2025-01-09 07:56
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting in the title parameter.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:49.105Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://divd.nl/cves/CVE-2023-22585"
},
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22585",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T17:54:24.900440Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T17:54:39.118Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-EM100",
"vendor": "Danfoss",
"versions": [
{
"status": "affected",
"version": "\u003c 2.2.0.12"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Jony Schats (Hackdefense)"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Stan Plasmeijer (Hackdefense)"
},
{
"lang": "en",
"type": "analyst",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Max van der Horst (DIVD)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting in the title parameter."
}
],
"value": "The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting in the title parameter."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T07:56:42.249Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2023-22585/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Reflected Cross-Site Scripting in Danfoss AK-EM100",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2023-22585",
"datePublished": "2023-06-11T13:17:01.771Z",
"dateReserved": "2023-01-03T07:33:48.702Z",
"dateUpdated": "2025-01-09T07:56:42.249Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22586 (GCVE-0-2023-22586)
Vulnerability from cvelistv5
Published
2023-06-11 13:17
Modified
2025-01-09 07:56
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Summary
The Danfoss AK-EM100 web applications allow for Local File Inclusion in the file parameter.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:49.091Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://divd.nl/cves/CVE-2023-22586"
},
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22586",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T17:55:14.865496Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T17:55:23.020Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-EM100",
"vendor": "Danfoss",
"versions": [
{
"status": "affected",
"version": "\u003c 2.2.0.12"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Jony Schats (Hackdefense)"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Stan Plasmeijer (Hackdefense)"
},
{
"lang": "en",
"type": "analyst",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Max van der Horst (DIVD)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Danfoss AK-EM100 web applications allow for Local File Inclusion in the file parameter."
}
],
"value": "The Danfoss AK-EM100 web applications allow for Local File Inclusion in the file parameter."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T07:56:41.684Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2023-22586/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Local File Inclusion in Danfoss AK-EM100",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2023-22586",
"datePublished": "2023-06-11T13:17:01.615Z",
"dateReserved": "2023-01-03T07:33:48.702Z",
"dateUpdated": "2025-01-09T07:56:41.684Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25912 (GCVE-0-2023-25912)
Vulnerability from cvelistv5
Published
2023-06-11 13:17
Modified
2025-01-09 07:56
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Summary
The webreport generation feature in the Danfoss AK-EM100 allows an unauthorized actor to generate a web report that discloses sensitive information such as the internal IP address, usernames and internal device values.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:32:12.805Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"third-party-advisory",
"x_transferred"
],
"url": "https://divd.nl/cves/CVE-2023-25912"
},
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-25912",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T17:55:46.225288Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T17:55:59.632Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-EM100",
"vendor": "Danfoss",
"versions": [
{
"lessThanOrEqual": "2.2.0.12",
"status": "affected",
"version": "\u003c 2.2.0.12",
"versionType": "2.x.y.z"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Jony Schats (Hackdefense)"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Stan Plasmeijer (Hackdefense)"
},
{
"lang": "en",
"type": "analyst",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Max van der Horst (DIVD)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The webreport generation feature in the Danfoss AK-EM100 allows an unauthorized actor to generate a web report that discloses sensitive information such as the internal IP address, usernames and internal device values."
}
],
"value": "The webreport generation feature in the Danfoss AK-EM100 allows an unauthorized actor to generate a web report that discloses sensitive information such as the internal IP address, usernames and internal device values."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T07:56:42.597Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"issue-tracking",
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2023-25912/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2023-00021/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Webreport disclosure to unauthorized actor in Danfoss AK-EM100",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"value": "The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2023-25912",
"datePublished": "2023-06-11T13:17:01.462Z",
"dateReserved": "2023-02-16T14:22:41.966Z",
"dateUpdated": "2025-01-09T07:56:42.597Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}