CVE-2025-27026 (GCVE-0-2025-27026)

Vulnerability from cvelistv5 – Published: 2025-07-02 13:42 – Updated: 2025-07-02 20:22
VLAI
Title
Improper Access Control Granularity impacting Infinera G42
Summary
A missing double-check feature in the WebGUI for CLI deactivation in Infinera G42 version R6.1.3 allows an authenticated administrator to make other management interfaces unavailable via local and network interfaces. The CLI deactivation via the WebGUI does not only stop CLI interface but deactivates also Linux Shell, WebGUI and Physical Serial Console access. No confirmation is asked at deactivation time. Loosing access to these services device administrators are at risk of completely loosing device control.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-02 20:22 UTC
CWE
  • CWE-1220 - Insufficient Granularity of Access Control
Assigner
ENISA CNA
References
Impacted products
Vendor Product Version
Infinera G42 Affected: 6.1.3 , < 8.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27026",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-02T20:22:47.748223Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-02T20:22:57.416Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "G42",
          "vendor": "Infinera",
          "versions": [
            {
              "lessThan": "8.0",
              "status": "affected",
              "version": "6.1.3",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Agenzia per la Cybersicurezza Nazionale"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A missing double-check feature in the WebGUI for CLI deactivation in Infinera G42 \nversion R6.1.3 allows an authenticated administrator to make other \nmanagement interfaces unavailable via local and network interfaces. The CLI deactivation via the WebGUI does not only stop CLI interface but deactivates also Linux Shell, WebGUI and Physical Serial Console access. No \nconfirmation is asked at deactivation time. Loosing access to these services device administrators are at risk of completely loosing device control.\u003cbr\u003e"
            }
          ],
          "value": "A missing double-check feature in the WebGUI for CLI deactivation in Infinera G42 \nversion R6.1.3 allows an authenticated administrator to make other \nmanagement interfaces unavailable via local and network interfaces. The CLI deactivation via the WebGUI does not only stop CLI interface but deactivates also Linux Shell, WebGUI and Physical Serial Console access. No \nconfirmation is asked at deactivation time. Loosing access to these services device administrators are at risk of completely loosing device control."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1220",
              "description": "CWE-1220: Insufficient Granularity of Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-02T13:42:42.068Z",
        "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "shortName": "ENISA"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2025-27026"
        },
        {
          "tags": [
            "vdb-entry"
          ],
          "url": "https://euvd.enisa.europa.eu/vulnerability/CVE-2025-27026"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper Access Control Granularity impacting Infinera G42",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
    "assignerShortName": "ENISA",
    "cveId": "CVE-2025-27026",
    "datePublished": "2025-07-02T13:42:42.068Z",
    "dateReserved": "2025-02-18T06:59:55.889Z",
    "dateUpdated": "2025-07-02T20:22:57.416Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-27026",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-02T20:22:47.748223Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-02T20:22:54.142Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "G42",
              "vendor": "Infinera",
              "versions": [
                {
                  "lessThan": "8.0",
                  "status": "affected",
                  "version": "6.1.3",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Agenzia per la Cybersicurezza Nazionale"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A missing double-check feature in the WebGUI for CLI deactivation in Infinera G42 \nversion R6.1.3 allows an authenticated administrator to make other \nmanagement interfaces unavailable via local and network interfaces. The CLI deactivation via the WebGUI does not only stop CLI interface but deactivates also Linux Shell, WebGUI and Physical Serial Console access. No \nconfirmation is asked at deactivation time. Loosing access to these services device administrators are at risk of completely loosing device control.\u003cbr\u003e"
                }
              ],
              "value": "A missing double-check feature in the WebGUI for CLI deactivation in Infinera G42 \nversion R6.1.3 allows an authenticated administrator to make other \nmanagement interfaces unavailable via local and network interfaces. The CLI deactivation via the WebGUI does not only stop CLI interface but deactivates also Linux Shell, WebGUI and Physical Serial Console access. No \nconfirmation is asked at deactivation time. Loosing access to these services device administrators are at risk of completely loosing device control."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1220",
                  "description": "CWE-1220: Insufficient Granularity of Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-02T13:42:42.068Z",
            "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "shortName": "ENISA"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2025-27026"
            },
            {
              "tags": [
                "vdb-entry"
              ],
              "url": "https://euvd.enisa.europa.eu/vulnerability/CVE-2025-27026"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Improper Access Control Granularity impacting Infinera G42",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "assignerShortName": "ENISA",
        "cveId": "CVE-2025-27026",
        "datePublished": "2025-07-02T13:42:42.068Z",
        "dateReserved": "2025-02-18T06:59:55.889Z",
        "dateUpdated": "2025-07-02T20:22:57.416Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.