CVE-2021-22749 (GCVE-0-2021-22749)
Vulnerability from cvelistv5
Published
2021-06-11 15:40
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Summary
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially crafted HTTP request is sent to the web server of the module.
References
| URL | Tags | |
|---|---|---|
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior |
Version: Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.224Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially crafted HTTP request is sent to the web server of the module."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-11T15:40:45.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22749",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior",
"version": {
"version_data": [
{
"version_value": "Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially crafted HTTP request is sent to the web server of the module."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-05",
"refsource": "MISC",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22749",
"datePublished": "2021-06-11T15:40:45.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.224Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…