Refine your search

305 vulnerabilities found for by Schneider Electric

CVE-2026-12927 (GCVE-0-2026-12927)
Vulnerability from cvelistv5
Published
2026-07-29 12:37
Modified
2026-07-29 14:19
CWE
Summary
CWE-787 Out-of-bounds write vulnerability exists that could cause loss of data or potentially risk arbitrary code execution when a malicious CGF file is imported to IGSS Definition.
Impacted products
Vendor Product Version
Schneider Electric IGSS Definition (Def.exe) Version: Version 18.0.0.26124 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-12927",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-29T14:18:59.870234Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-29T14:19:12.306Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "IGSS Definition (Def.exe)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 18.0.0.26124 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-787 Out-of-bounds write vulnerability exists that could cause loss of data or potentially risk arbitrary code execution when a malicious CGF file is imported to IGSS Definition."
            }
          ],
          "value": "CWE-787 Out-of-bounds write vulnerability exists that could cause loss of data or potentially risk arbitrary code execution when a malicious CGF file is imported to IGSS Definition."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-29T12:37:47.199Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.se.com/files?p_Doc_Ref=SEVD-2026-195-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-195-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.4"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-12927",
    "datePublished": "2026-07-29T12:37:47.199Z",
    "dateReserved": "2026-06-22T17:23:06.940Z",
    "dateUpdated": "2026-07-29T14:19:12.306Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-0667 (GCVE-0-2026-0667)
Vulnerability from cvelistv5
Published
2026-07-29 12:35
Modified
2026-07-29 14:20
CWE
  • CWE-754 - Improper Check for Unusual or Exceptional Conditions
Summary
CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when communicating over the Modbus TCP protocol.
Impacted products
Vendor Product Version
Schneider Electric SCADAPack 47x Version: Versions prior to R3.4.2 (Firmware version prior to 9.12.2)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-0667",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-29T14:19:55.842761Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-29T14:20:14.876Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SCADAPack 47x",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to R3.4.2 (Firmware version prior to 9.12.2)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SCADAPack 47xi",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to R3.4.2 (Firmware version prior to 9.12.2)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SCADAPack 57x",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RemoteConnect",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to R3.4.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality \u0026amp; integrity when communicating over the Modbus TCP protocol."
            }
          ],
          "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality \u0026 integrity when communicating over the Modbus TCP protocol."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-29T12:35:34.208Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.se.com/files?p_Doc_Ref=SEVD-2026-041-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-041-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.4"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-0667",
    "datePublished": "2026-07-29T12:35:34.208Z",
    "dateReserved": "2026-01-07T15:42:11.892Z",
    "dateUpdated": "2026-07-29T14:20:14.876Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-14354 (GCVE-0-2026-14354)
Vulnerability from cvelistv5
Published
2026-07-29 11:54
Modified
2026-07-29 12:42
CWE
  • CWE-522 - Insufficiently Protected Credentials
Summary
CWE-522 Insufficiently Protected Credentials vulnerability exists that could cause authentication bypass and unauthorized credential modification, potentially leading to compromise of managed devices, when a local privileged attacker leverages weaknesses in the handling and protection of stored credentials within the application.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-14354",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-29T12:42:16.227686Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-29T12:42:22.173Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure\u2122 Cybersecurity Admin Expert",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "v4.2.0 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-522 Insufficiently Protected Credentials vulnerability exists that could cause authentication bypass and unauthorized credential modification, potentially leading to compromise of managed devices, when a local privileged attacker leverages weaknesses in the handling and protection of stored credentials within the application."
            }
          ],
          "value": "CWE-522 Insufficiently Protected Credentials vulnerability exists that could cause authentication bypass and unauthorized credential modification, potentially leading to compromise of managed devices, when a local privileged attacker leverages weaknesses in the handling and protection of stored credentials within the application."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "CWE-522 Insufficiently Protected Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-29T11:54:46.553Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.se.com/files?p_Doc_Ref=SEVD-2026-195-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-195-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.4"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-14354",
    "datePublished": "2026-07-29T11:54:46.553Z",
    "dateReserved": "2026-07-01T17:31:38.767Z",
    "dateUpdated": "2026-07-29T12:42:22.173Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-9718 (GCVE-0-2026-9718)
Vulnerability from cvelistv5
Published
2026-06-25 15:07
Modified
2026-06-25 15:51
CWE
Summary
CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable network-exposed service.
Impacted products
Vendor Product Version
Schneider Electric PowerLogic™ P7 Version: Version V02.003.001.000 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9718",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-25T15:50:42.425510Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-25T15:51:23.849Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerLogic\u2122 P7",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version V02.003.001.000 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable network-exposed service."
            }
          ],
          "value": "CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable network-exposed service."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-617",
              "description": "CWE-617 Reachable assertion",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-25T15:07:23.973Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-160-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-9718",
    "datePublished": "2026-06-25T15:07:23.973Z",
    "dateReserved": "2026-05-27T16:02:13.186Z",
    "dateUpdated": "2026-06-25T15:51:23.849Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-9717 (GCVE-0-2026-9717)
Vulnerability from cvelistv5
Published
2026-06-25 15:05
Modified
2026-06-25 15:50
CWE
  • CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
Summary
CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.
Impacted products
Vendor Product Version
Schneider Electric PowerLogic™ P7 Version: Version V02.003.001.000 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9717",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-25T15:50:24.128307Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-25T15:50:30.499Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerLogic\u2122 P7",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version V02.003.001.000 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-78 Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service."
            }
          ],
          "value": "CWE-78 Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-25T15:05:36.423Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-160-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-9717",
    "datePublished": "2026-06-25T15:05:36.423Z",
    "dateReserved": "2026-05-27T16:02:10.875Z",
    "dateUpdated": "2026-06-25T15:50:30.499Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-9716 (GCVE-0-2026-9716)
Vulnerability from cvelistv5
Published
2026-06-25 15:02
Modified
2026-06-25 15:49
CWE
  • CWE-476 - NULL pointer dereference
Summary
CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces.
Impacted products
Vendor Product Version
Schneider Electric PowerLogic™ P7 Version: Version V02.003.001.000 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9716",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-25T15:49:53.446856Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-25T15:49:59.528Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerLogic\u2122 P7",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version V02.003.001.000 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device\u2019s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces."
            }
          ],
          "value": "CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device\u2019s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476 NULL pointer dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-25T15:02:28.169Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-160-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-9716",
    "datePublished": "2026-06-25T15:02:28.169Z",
    "dateReserved": "2026-05-27T16:02:10.007Z",
    "dateUpdated": "2026-06-25T15:49:59.528Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-9651 (GCVE-0-2026-9651)
Vulnerability from cvelistv5
Published
2026-06-25 14:47
Modified
2026-06-25 15:49
CWE
  • CWE-732 - Incorrect Permission Assignment for Critical Resource
Summary
CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9651",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-25T15:49:29.524994Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-25T15:49:36.271Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit \u0026 Controller",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.06.31 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Saitel DP Remote Terminal Unit \u0026 Controller",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.06.37 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files."
            }
          ],
          "value": "CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-25T14:47:24.496Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-160-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-9651",
    "datePublished": "2026-06-25T14:47:24.496Z",
    "dateReserved": "2026-05-26T19:45:22.354Z",
    "dateUpdated": "2026-06-25T15:49:36.271Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-9650 (GCVE-0-2026-9650)
Vulnerability from cvelistv5
Published
2026-06-25 14:44
Modified
2026-06-25 15:49
CWE
  • CWE-522 - Insufficiently Protected Credentials
Summary
CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9650",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-25T15:48:51.280291Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-25T15:49:18.212Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit \u0026 Controller",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.06.30 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Saitel DP Remote Terminal Unit \u0026 Controller",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.06.35 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device."
            }
          ],
          "value": "CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "CWE-522 Insufficiently Protected Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-25T14:47:54.309Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-160-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-9650",
    "datePublished": "2026-06-25T14:44:30.419Z",
    "dateReserved": "2026-05-26T19:45:16.940Z",
    "dateUpdated": "2026-06-25T15:49:18.212Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-8045 (GCVE-0-2026-8045)
Vulnerability from cvelistv5
Published
2026-06-09 14:41
Modified
2026-06-09 16:01
CWE
  • CWE-611 - Improper restriction of XML external entity reference
Summary
CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-8045",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-09T16:01:04.840915Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-09T16:01:11.879Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure\u2122 IT Data Center Expert",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "v9.1.1 and Prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints."
            }
          ],
          "value": "CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "CWE-611 Improper restriction of XML external entity reference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-09T14:41:56.266Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-160-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-8045",
    "datePublished": "2026-06-09T14:41:56.266Z",
    "dateReserved": "2026-05-06T17:07:12.846Z",
    "dateUpdated": "2026-06-09T16:01:11.879Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-6332 (GCVE-0-2026-6332)
Vulnerability from cvelistv5
Published
2026-05-14 16:54
Modified
2026-05-14 18:37
CWE
  • CWE-312 - Cleartext storage of sensitive information
Summary
CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that could cause the disclosure of a sensitive information which could result in revealing protected source code and loss of confidentiality, When an authorized attacker accesses the source code for editing or compiling it.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-6332",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-14T18:37:08.735767Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-14T18:37:23.728Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Ecostruxure\u2122 Machine Expert HVAC",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 1.10.0"
            }
          ]
        }
      ],
      "datePublic": "2026-05-12T16:49:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that could cause the disclosure of a sensitive information  which could result in revealing protected source code and loss of confidentiality, When an authorized attacker accesses the source code for editing or compiling it."
            }
          ],
          "value": "CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that could cause the disclosure of a sensitive information  which could result in revealing protected source code and loss of confidentiality, When an authorized attacker accesses the source code for editing or compiling it."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext storage of sensitive information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-14T16:54:50.465Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-132-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Clear Text Storage of Sensitive Information on EcoStruxure\u2122 Machine Expert HVAC",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-6332",
    "datePublished": "2026-05-14T16:54:50.465Z",
    "dateReserved": "2026-04-15T07:55:30.087Z",
    "dateUpdated": "2026-05-14T18:37:23.728Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-6866 (GCVE-0-2026-6866)
Vulnerability from cvelistv5
Published
2026-05-12 13:59
Modified
2026-05-12 15:43
CWE
  • CWE-1188 - Initialization of a resource with an insecure default
Summary
CWE-1188 Initialization of a Resource with an Insecure Default vulnerability exists that could cause unauthorized disclosure of sensitive information when credentials revert to initial settings in rare circumstances, enabling unauthorized authentication using known credentials.
Impacted products
Vendor Product Version
Schneider Electric EcoStruxure™ Panel Server Version: Versions 002.005.000 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-6866",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-12T15:43:29.539824Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-12T15:43:40.858Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "PAS400",
            "PAS600",
            "PAS600V2",
            "PAS800",
            "PAS800V2"
          ],
          "product": "EcoStruxure\u2122 Panel Server",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 002.005.000 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-1188 Initialization of a Resource with an Insecure Default vulnerability exists that could cause unauthorized disclosure of sensitive information when credentials revert to initial settings in rare circumstances, enabling unauthorized authentication using known credentials."
            }
          ],
          "value": "CWE-1188 Initialization of a Resource with an Insecure Default vulnerability exists that could cause unauthorized disclosure of sensitive information when credentials revert to initial settings in rare circumstances, enabling unauthorized authentication using known credentials."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188 Initialization of a resource with an insecure default",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-12T13:59:33.610Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-132-04.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Initialization of a Resource with an Insecure Default vulnerability on EcoStruxure\u2122 Panel Server",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-6866",
    "datePublished": "2026-05-12T13:59:33.610Z",
    "dateReserved": "2026-04-22T16:17:46.134Z",
    "dateUpdated": "2026-05-12T15:43:40.858Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-6865 (GCVE-0-2026-6865)
Vulnerability from cvelistv5
Published
2026-05-12 12:29
Modified
2026-05-12 14:36
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory (“Path Traversal”)
Summary
CWE-22: Improper Limitation of a Pathname to a Restricted Directory (“Path Traversal”) vulnerability that could cause unauthorized access to sensitive files when user-supplied input is improperly handled during server-side file path processing.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-6865",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-12T14:35:42.694103Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-12T14:36:00.520Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit \u0026 Controller",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 11.06.31 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Saitel DP Remote Terminal Unit \u0026 Controller",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 11.06.36 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u201cPath Traversal\u201d) vulnerability that could cause unauthorized access to sensitive files when user-supplied input is improperly handled during server-side file path processing."
            }
          ],
          "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u201cPath Traversal\u201d) vulnerability that could cause unauthorized access to sensitive files when user-supplied input is improperly handled during server-side file path processing."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u201cPath Traversal\u201d)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-12T12:29:51.590Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-132-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper Limitation of a Pathname to a Restricted Directory Vulnerability on Multiple Products",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-6865",
    "datePublished": "2026-05-12T12:29:51.590Z",
    "dateReserved": "2026-04-22T16:17:43.729Z",
    "dateUpdated": "2026-05-12T14:36:00.520Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-4827 (GCVE-0-2026-4827)
Vulnerability from cvelistv5
Published
2026-05-12 12:24
Modified
2026-05-14 17:38
CWE
Summary
CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections.
Impacted products
Vendor Product Version
Schneider Electric Easergy MiCOM C264 Version: Versions D6.x
Version: Versions D7.33 and prior
Create a notification for this product.
   Schneider Electric Easergy C5 Version: Version 1.1.17 and prior
Create a notification for this product.
   Schneider Electric Easergy MiCOM P30 Version: P139 version prior to P139.678.700
Version: P437 version prior to P437.678.700
Version: P439 version prior to P439.678.700
Version: P532 version prior to P532.678.700
Version: P539 version prior to P539.678.700
Version: P631 version prior to P631.678.700
Version: P632 version prior to P632.678.700
Version: P633 version prior to P633.678.700
Version: P634 version prior to P634.678.700
Version: P633 version P633.680.700 only
Version: P634 version P634.680.700 only
Version: P138 version prior to P138.677.700
Version: P436 version prior to P436.677.701
Version: P438 version prior to P438.677.701
Version: P638 version prior to P638.677.700
Version: C434 version prior to C434.679.700
Create a notification for this product.
   Schneider Electric Easergy MiCOM P40 Version: Series model numbers with Protocol Option bit as G, H or L and all firmware versions
Create a notification for this product.
   Schneider Electric EcoStruxure™ Power Automation System Gateway (EPAS-GTW) Version: Version 6.4.616.200.100 and prior
Create a notification for this product.
   Schneider Electric EcoStruxure™ Power Automation System User Interface (EPAS-UI) Version: Version 3.0.3 and prior
Create a notification for this product.
   Schneider Electric EcoStruxure™ Power Operation Version: Version 2022 CU6 and prior
Version: Version 2024 CU2 and prior
Create a notification for this product.
   Schneider Electric iPMFLS Version: Version 64.2025.0.13 and prior
Create a notification for this product.
   Schneider Electric PowerLogic™ P5 Protection Relay Version: V02.502.103 and prior
Create a notification for this product.
   Schneider Electric PowerLogic™ P7 Protection and Control Platform Version: V02.002.002 and prior
Create a notification for this product.
   Schneider Electric PowerLogic™ T300 Version: Version 2.9.4 and prior
Create a notification for this product.
   Schneider Electric PowerLogic™ T500 Version: Version 11.08.02 and prior
Create a notification for this product.
   Schneider Electric Saitel DP Version: Version 11.06.36 and prior
Create a notification for this product.
   Schneider Electric EasyLogic T150 (formerly Saitel DR) Version: Version 11.06.30 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-4827",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-12T12:39:02.210471Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-12T12:39:31.579Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM C264",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions D6.x"
            },
            {
              "status": "affected",
              "version": "Versions D7.33 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy C5",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 1.1.17 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P30",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "P139 version prior to P139.678.700"
            },
            {
              "status": "affected",
              "version": "P437 version prior to P437.678.700"
            },
            {
              "status": "affected",
              "version": "P439 version prior to P439.678.700"
            },
            {
              "status": "affected",
              "version": "P532 version prior to P532.678.700"
            },
            {
              "status": "affected",
              "version": "P539 version prior to P539.678.700"
            },
            {
              "status": "affected",
              "version": "P631 version prior to P631.678.700"
            },
            {
              "status": "affected",
              "version": "P632 version prior to P632.678.700"
            },
            {
              "status": "affected",
              "version": "P633 version prior to P633.678.700"
            },
            {
              "status": "affected",
              "version": "P634 version prior to P634.678.700"
            },
            {
              "status": "affected",
              "version": "P633 version P633.680.700 only"
            },
            {
              "status": "affected",
              "version": "P634 version P634.680.700 only"
            },
            {
              "status": "affected",
              "version": "P138 version prior to P138.677.700"
            },
            {
              "status": "affected",
              "version": "P436 version prior to P436.677.701"
            },
            {
              "status": "affected",
              "version": "P438 version prior to P438.677.701"
            },
            {
              "status": "affected",
              "version": "P638 version prior to P638.677.700"
            },
            {
              "status": "affected",
              "version": "C434 version prior to C434.679.700"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P40",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Series model numbers with Protocol Option bit as G, H or L and all firmware versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure\u2122 Power Automation System Gateway (EPAS-GTW)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 6.4.616.200.100 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure\u2122 Power Automation System User Interface (EPAS-UI)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 3.0.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure\u2122 Power Operation",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 2022 CU6 and prior"
            },
            {
              "status": "affected",
              "version": "Version 2024 CU2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "iPMFLS",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 64.2025.0.13 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PowerLogic\u2122 P5 Protection Relay",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V02.502.103 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PowerLogic\u2122 P7 Protection and Control Platform",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V02.002.002 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PowerLogic\u2122 T300",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 2.9.4 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PowerLogic\u2122 T500",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.08.02 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Saitel DP",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.06.36 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EasyLogic T150 (formerly Saitel DR)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11.06.30 and prior"
            }
          ]
        }
      ],
      "datePublic": "2026-05-12T16:49:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE\u2011331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session\u2011management protections."
            }
          ],
          "value": "CWE\u2011331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session\u2011management protections."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-331",
              "description": "CWE-331 Insufficient entropy",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-14T17:38:38.647Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-132-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insufficient Entropy vulnerability on Multiple Products",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-4827",
    "datePublished": "2026-05-12T12:24:22.928Z",
    "dateReserved": "2026-03-25T14:07:29.111Z",
    "dateUpdated": "2026-05-14T17:38:38.647Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2401 (GCVE-0-2026-2401)
Vulnerability from cvelistv5
Published
2026-04-14 15:24
Modified
2026-04-14 16:27
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Summary
CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2401",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-14T16:23:13.716274Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-14T16:27:16.331Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerChute\u2122 Serial Shutdown",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 1.4 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause  confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker."
            }
          ],
          "value": "CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause  confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 2.4,
            "baseSeverity": "LOW",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-14T15:24:17.233Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-2401",
    "datePublished": "2026-04-14T15:24:17.233Z",
    "dateReserved": "2026-02-12T13:18:59.627Z",
    "dateUpdated": "2026-04-14T16:27:16.331Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2400 (GCVE-0-2026-2400)
Vulnerability from cvelistv5
Published
2026-04-14 15:22
Modified
2026-04-14 16:27
CWE
  • CWE-93 - Improper Neutralization of CRLF Sequences ('CRLF Injection')
Summary
CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists that could cause application user credentials to reset when a Web Admin user alters the POST /setPCBEDesc request payload.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2400",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-14T16:23:35.812067Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-14T16:27:22.220Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerChute\u2122 Serial Shutdown",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 1.4 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-93 Improper Neutralization of CRLF Sequences (\u0027CRLF Injection\u0027) vulnerability exists that could cause application user credentials to reset  when  a Web Admin user alters the POST /setPCBEDesc request payload."
            }
          ],
          "value": "CWE-93 Improper Neutralization of CRLF Sequences (\u0027CRLF Injection\u0027) vulnerability exists that could cause application user credentials to reset  when  a Web Admin user alters the POST /setPCBEDesc request payload."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-93",
              "description": "CWE-93 Improper Neutralization of CRLF Sequences (\u0027CRLF Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-14T15:22:53.245Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-2400",
    "datePublished": "2026-04-14T15:22:53.245Z",
    "dateReserved": "2026-02-12T13:17:07.149Z",
    "dateUpdated": "2026-04-14T16:27:22.220Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2403 (GCVE-0-2026-2403)
Vulnerability from cvelistv5
Published
2026-04-14 15:21
Modified
2026-04-14 16:27
CWE
  • CWE-1284 - Improper Validation of Specified Quantity in Input
Summary
CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a Web Admin user alters the POST /logsettings request payload.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2403",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-14T16:23:47.895593Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-14T16:27:27.629Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerChute\u2122 Serial Shutdown",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 1.4 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a Web Admin user alters the POST /logsettings request payload."
            }
          ],
          "value": "CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a Web Admin user alters the POST /logsettings request payload."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1284",
              "description": "CWE-1284 Improper Validation of Specified Quantity in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-14T15:21:10.802Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-2403",
    "datePublished": "2026-04-14T15:21:10.802Z",
    "dateReserved": "2026-02-12T13:19:02.490Z",
    "dateUpdated": "2026-04-14T16:27:27.629Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2405 (GCVE-0-2026-2405)
Vulnerability from cvelistv5
Published
2026-04-14 15:19
Modified
2026-04-14 16:27
CWE
  • CWE-400 - Uncontrolled Resource Consumption
Summary
CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web Admin user floods the system with POST /helpabout requests.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2405",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-14T16:25:50.086988Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-14T16:27:33.148Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerChute\u2122 Serial Shutdown",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 1.4 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web Admin user floods the system with POST /helpabout requests."
            }
          ],
          "value": "CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web Admin user floods the system with POST /helpabout requests."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-14T15:19:40.765Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-2405",
    "datePublished": "2026-04-14T15:19:40.765Z",
    "dateReserved": "2026-02-12T13:19:05.750Z",
    "dateUpdated": "2026-04-14T16:27:33.148Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2402 (GCVE-0-2026-2402)
Vulnerability from cvelistv5
Published
2026-04-14 15:16
Modified
2026-04-14 16:27
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
Summary
CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2402",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-14T16:26:07.842287Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-14T16:27:38.566Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerChute\u2122 Serial Shutdown",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions v1.4 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints."
            }
          ],
          "value": "CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-14T15:16:42.073Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-2402",
    "datePublished": "2026-04-14T15:16:17.583Z",
    "dateReserved": "2026-02-12T13:19:01.113Z",
    "dateUpdated": "2026-04-14T16:27:38.566Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2404 (GCVE-0-2026-2404)
Vulnerability from cvelistv5
Published
2026-04-14 15:13
Modified
2026-04-14 16:27
CWE
  • CWE-116 - Improper Encoding or Escaping of Output
Summary
CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2404",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-14T16:26:32.467506Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-14T16:27:43.927Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerChute\u2122 Serial Shutdown",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 1.4 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload."
            }
          ],
          "value": "CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-116",
              "description": "CWE-116 Improper Encoding or Escaping of Output",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-14T15:13:50.351Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-2404",
    "datePublished": "2026-04-14T15:13:50.351Z",
    "dateReserved": "2026-02-12T13:19:03.924Z",
    "dateUpdated": "2026-04-14T16:27:43.927Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2399 (GCVE-0-2026-2399)
Vulnerability from cvelistv5
Published
2026-04-14 15:09
Modified
2026-04-14 15:52
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2399",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-14T15:51:11.359624Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-14T15:52:07.599Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerChute\u2122 Serial Shutdown",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 1.4 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload."
            }
          ],
          "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-14T15:09:58.751Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-2399",
    "datePublished": "2026-04-14T15:09:58.751Z",
    "dateReserved": "2026-02-12T13:16:54.228Z",
    "dateUpdated": "2026-04-14T15:52:07.599Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-4832 (GCVE-0-2026-4832)
Vulnerability from cvelistv5
Published
2026-04-14 15:05
Modified
2026-04-14 18:16
CWE
  • CWE-798 - Use of Hard-Coded Credentials
Summary
CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port.
Impacted products
Vendor Product Version
Schneider Electric Easergy MiCOM P14x Version: All versions prior to B4A
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-4832",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-14T18:15:51.123382Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-14T18:16:06.726Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P14x",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to B4A"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P24x",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to D3A"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P341",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to E3F"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P342, P343, P344, P345",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to B3F"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P442, P444",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to E3A"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P443, P445, P446, P543, P544, P545, P546",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to H6A"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P642, P645",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to B4A"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P643",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to B3F"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P741, P742, P743",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to B2A"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P746",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to B4E or C4E"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P841",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to G6A"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Easergy MiCOM P849",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to B4A"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port."
            }
          ],
          "value": "CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-Coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-14T15:17:08.719Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-4832",
    "datePublished": "2026-04-14T15:05:00.845Z",
    "dateReserved": "2026-03-25T14:13:10.490Z",
    "dateUpdated": "2026-04-14T18:16:06.726Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2273 (GCVE-0-2026-2273)
Vulnerability from cvelistv5
Published
2026-03-10 17:18
Modified
2026-03-10 17:42
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Summary
CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2273",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T17:42:09.226674Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-10T17:42:47.751Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure\u2122 Automation Expert",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to v25.0.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file."
            }
          ],
          "value": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:A/VC:L/VI:H/VA:L/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-10T17:18:39.374Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-069-04.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-2273",
    "datePublished": "2026-03-10T17:18:39.374Z",
    "dateReserved": "2026-02-10T09:45:08.807Z",
    "dateUpdated": "2026-03-10T17:42:47.751Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-1286 (GCVE-0-2026-1286)
Vulnerability from cvelistv5
Published
2026-03-10 17:09
Modified
2026-03-10 17:55
CWE
  • CWE-502 - Deserialization of untrusted data
Summary
CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file.
Impacted products
Vendor Product Version
Schneider Electric EcoStruxure™ Foxboro DCS Version: Versions prior to CS8.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-1286",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T17:54:10.514863Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-10T17:55:36.889Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure\u2122 Foxboro DCS",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to CS8.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file."
            }
          ],
          "value": "CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-502",
              "description": "CWE-502 Deserialization of untrusted data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-10T17:09:18.120Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-069-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-1286",
    "datePublished": "2026-03-10T17:09:18.120Z",
    "dateReserved": "2026-01-21T13:15:37.247Z",
    "dateUpdated": "2026-03-10T17:55:36.889Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13902 (GCVE-0-2025-13902)
Vulnerability from cvelistv5
Published
2026-03-10 17:06
Modified
2026-03-10 18:19
CWE
  • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
Summary
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13902",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T18:17:03.131045Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-10T18:19:19.395Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Modicon Controllers M241/M251",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 5.4.13.12"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon Controllers M258/LMC058",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause condition where authenticated attackers can have a victim\u2019s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload."
            }
          ],
          "value": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause condition where authenticated attackers can have a victim\u2019s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-10T17:11:39.985Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-069-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2025-13902",
    "datePublished": "2026-03-10T17:06:00.208Z",
    "dateReserved": "2025-12-02T16:20:41.599Z",
    "dateUpdated": "2026-03-10T18:19:19.395Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13901 (GCVE-0-2025-13901)
Vulnerability from cvelistv5
Published
2026-03-10 17:02
Modified
2026-03-10 17:25
CWE
  • CWE-404 - Improper Resource Shutdown or Release
Summary
CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.
Impacted products
Vendor Product Version
Schneider Electric Modicon M241/M251 Version: Versions prior to 5.4.13.12
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13901",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T17:24:36.387715Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-10T17:25:20.028Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Modicon M241/M251",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 5.4.13.12"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon M262",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 5.4.10.12"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels."
            }
          ],
          "value": "CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-404",
              "description": "CWE-404 Improper Resource Shutdown or Release",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-10T17:12:53.896Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-069-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2025-13901",
    "datePublished": "2026-03-10T17:02:22.998Z",
    "dateReserved": "2025-12-02T16:20:27.551Z",
    "dateUpdated": "2026-03-10T17:25:20.028Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-11739 (GCVE-0-2025-11739)
Vulnerability from cvelistv5
Published
2026-03-10 12:25
Modified
2026-03-10 17:26
CWE
  • CWE-502 - Deserialization of untrusted data
Summary
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.
Impacted products
Vendor Product Version
Schneider Electric EcoStruxure™ Power Monitoring Expert (PME) Version: Version 2022
Version: Version 2023
Version: Version 2023 R2
Version: Version 2024
Version: Version 2024 R2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11739",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T13:33:55.316218Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-10T13:34:01.324Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure\u2122 Power Monitoring Expert (PME)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 2022"
            },
            {
              "status": "affected",
              "version": "Version 2023"
            },
            {
              "status": "affected",
              "version": "Version 2023 R2"
            },
            {
              "status": "affected",
              "version": "Version 2024"
            },
            {
              "status": "affected",
              "version": "Version 2024 R2"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 2022"
            },
            {
              "status": "affected",
              "version": "Version 2024"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE\u2011502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization."
            }
          ],
          "value": "CWE\u2011502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-502",
              "description": "CWE-502 Deserialization of untrusted data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-10T17:26:25.203Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-069-06.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2025-11739",
    "datePublished": "2026-03-10T12:25:14.501Z",
    "dateReserved": "2025-10-14T13:43:50.195Z",
    "dateUpdated": "2026-03-10T17:26:25.203Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13957 (GCVE-0-2025-13957)
Vulnerability from cvelistv5
Published
2026-03-10 12:19
Modified
2026-03-10 17:21
CWE
  • CWE-798 - Use of Hard-coded Credentials
Summary
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13957",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T13:42:04.681474Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-10T13:42:15.777Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure\u2122 IT Data Center Expert (Formerly known as StruxureWare Data Center Expert)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "v9.0 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default."
            }
          ],
          "value": "CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-10T17:21:41.222Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-069-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2025-13957",
    "datePublished": "2026-03-10T12:19:04.041Z",
    "dateReserved": "2025-12-03T14:05:40.047Z",
    "dateUpdated": "2026-03-10T17:21:41.222Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-1226 (GCVE-0-2026-1226)
Vulnerability from cvelistv5
Published
2026-02-11 13:49
Modified
2026-02-11 14:07
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Summary
CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-1226",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-11T14:07:20.670514Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-11T14:07:27.708Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Building Operation Workstation",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All 7.0.x versions prior to 7.0.2"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Building Operation Webstation",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All 6.0.x versions prior to 6.0.4.7000 (CP5)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE\u201194: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file."
            }
          ],
          "value": "CWE\u201194: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-11T13:49:45.465Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-041-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-041-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-1226",
    "datePublished": "2026-02-11T13:49:45.465Z",
    "dateReserved": "2026-01-20T12:38:21.548Z",
    "dateUpdated": "2026-02-11T14:07:27.708Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-1227 (GCVE-0-2026-1227)
Vulnerability from cvelistv5
Published
2026-02-11 13:45
Modified
2026-02-11 14:08
CWE
  • CWE-611 - Improper Restriction of XML External Entity Reference
Summary
CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized disclosure of local files, interaction within the EBO system, or denial of service conditions when a local user uploads a specially crafted TGML graphics file to the EBO server from Workstation.
Impacted products
Vendor Product Version
Schneider Electric EcoStruxure Building Operation Workstation Version: All 7.0.x versions prior to 7.0.3.2000 (CP1)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-1227",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-11T14:08:12.326386Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-11T14:08:24.750Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Building Operation Workstation",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All 7.0.x versions prior to 7.0.3.2000 (CP1)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Building Operation Webstation",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All 6.x versions prior to 6.0.4.14001 (CP10)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized disclosure of local files, interaction within the EBO system, or denial of service conditions when a local user uploads a specially crafted TGML graphics file to the EBO server from Workstation."
            }
          ],
          "value": "CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized disclosure of local files, interaction within the EBO system, or denial of service conditions when a local user uploads a specially crafted TGML graphics file to the EBO server from Workstation."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "CWE-611 Improper Restriction of XML External Entity Reference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-11T13:45:51.675Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-041-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-041-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-1227",
    "datePublished": "2026-02-11T13:45:51.675Z",
    "dateReserved": "2026-01-20T12:38:23.080Z",
    "dateUpdated": "2026-02-11T14:08:24.750Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13905 (GCVE-0-2025-13905)
Vulnerability from cvelistv5
Published
2026-01-29 15:20
Modified
2026-01-29 16:10
CWE
  • CWE-276 - Incorrect Default Permissions
Summary
CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13905",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-29T15:50:11.436614Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-29T16:10:59.092Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure\u2122 Process Expert",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 2025"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure\u2122 Process Expert for AVEVA System Platform",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "datePublic": "2026-01-13T15:18:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-276: Incorrect Default Permissions vulnerability exists that could cause  privilege escalation through the reverse shell when  one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart."
            }
          ],
          "value": "CWE-276: Incorrect Default Permissions vulnerability exists that could cause  privilege escalation through the reverse shell when  one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276 Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-29T15:20:45.864Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2025-13905",
    "datePublished": "2026-01-29T15:20:45.864Z",
    "dateReserved": "2025-12-02T16:35:40.124Z",
    "dateUpdated": "2026-01-29T16:10:59.092Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}