Search
Find a vulnerability
Search criteria
4 vulnerabilities found for WebSAM WinShare by NEC Corporation
JVNDB-2026-000163
Vulnerability from jvndb - Published: 2026-11-09 07:04 - Updated:2026-11-09 07:04
Severity
Summary
Multiple vulnerabilities in WebSAM WinShare
Details
WebSAM WinShare provided by NEC Corporation contains multiple vulnerabilities listed below.
- Incorrect default permissions in the program folder (CWE-276) - CVE-2026-113362
- Exposed dangerous method or function (CWE-749) - CVE-2026-113363
- Heap-based buffer overflow (CWE-122) - CVE-2026-113364
References
Impacted products
| Vendor | Product | |
|---|---|---|
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-000163.html",
"dc:date": "2026-11-09T16:04+09:00",
"dcterms:issued": "2026-11-09T16:04+09:00",
"dcterms:modified": "2026-11-09T16:04+09:00",
"description": "WebSAM WinShare provided by NEC Corporation contains multiple vulnerabilities listed below.\u003ca href=\u0027https://cwe.mitre.org/data/definitions/276.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/749.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/122.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003cul\u003e\u003cli\u003eIncorrect default permissions in the program folder (CWE-276) - CVE-2026-113362\u003c/li\u003e\u003cli\u003eExposed dangerous method or function (CWE-749) - CVE-2026-113363\u003c/li\u003e\u003cli\u003eHeap-based buffer overflow (CWE-122) - CVE-2026-113364\u003c/li\u003e\u003c/ul\u003eRuslan Sayfiev and Denis Faiustov of Fujitsu Limited, and Masahiro Kawada reported these vulnerabilities to IPA.\r\nJPCERT/CC coordinated with the developer under Information Security Early Warning Partnership.",
"link": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-000163.html",
"sec:cpe": {
"#text": "cpe:/a:nec:websam_winshare",
"@product": "WebSAM WinShare",
"@vendor": "NEC Corporation",
"@version": "2.2"
},
"sec:cvss": {
"@score": "9.8",
"@severity": "Critical",
"@type": "Base",
"@vector": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"@version": "3.0"
},
"sec:identifier": "JVNDB-2026-000163",
"sec:references": [
{
"#text": "https://jvn.jp/en/jp/JVN89009783/index.html",
"@id": "JVN#89009783",
"@source": "JVN"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-113362",
"@id": "CVE-2026-113362",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-113363",
"@id": "CVE-2026-113363",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-113364",
"@id": "CVE-2026-113364",
"@source": "CVE"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-119",
"@title": "Buffer Errors(CWE-119)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-Other",
"@title": "No Mapping(CWE-Other)"
}
],
"title": "Multiple vulnerabilities in WebSAM WinShare"
}
CVE-2026-113364 (GCVE-0-2026-113364)
Vulnerability from cvelistv5 – Published: 2026-11-09 04:14 – Updated: 2026-11-09 04:14
VLAI
EPSS
VEX
Summary
Buffer Overflow in the data receiving process in NEC Corporation WebSAM WinShare Ver 7.5.0 and earlier, Ver 7.6.0 and Ver 7.7.0 through 7.7.2 on Windows allows a remote unauthenticated attacker to execute arbitrary code with SYSTEM privileges via a crafted packet with a malformed data size value in the protocol header.
Severity
CWE
- CWE-122 - Heap-based buffer overflow
Assigner
NEC
CNA
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| NEC Corporation | WebSAM WinShare |
Affected:
Ver 7.5.0 and earlier, Ver 7.6.0 and Ver 7.7.0 through 7.7.2
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "WebSAM WinShare",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "Ver 7.5.0 and earlier, Ver 7.6.0 and Ver 7.7.0 through 7.7.2"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "reported by Ruslan Sayfiev and Denis Faiustov of Fujitsu Limited, and Masahiro Kawada."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Buffer Overflow in the data receiving process in NEC Corporation WebSAM WinShare Ver 7.5.0 and earlier, Ver 7.6.0 and Ver 7.7.0 through 7.7.2 on Windows allows a remote unauthenticated attacker to execute arbitrary code with SYSTEM privileges via a crafted packet with a malformed data size value in the protocol header."
}
],
"value": "Buffer Overflow in the data receiving process in NEC Corporation WebSAM WinShare Ver 7.5.0 and earlier, Ver 7.6.0 and Ver 7.7.0 through 7.7.2 on Windows allows a remote unauthenticated attacker to execute arbitrary code with SYSTEM privileges via a crafted packet with a malformed data size value in the protocol header."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based buffer overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T04:14:03.038Z",
"orgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
"shortName": "NEC"
},
"references": [
{
"url": "https://jpn.nec.com/security-info/secinfo/nv26-006_en.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
"assignerShortName": "NEC",
"cveId": "CVE-2026-113364",
"datePublished": "2026-11-09T04:14:03.038Z",
"dateReserved": "2026-10-20T01:52:48.107Z",
"dateUpdated": "2026-11-09T04:14:03.038Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-113363 (GCVE-0-2026-113363)
Vulnerability from cvelistv5 – Published: 2026-11-09 04:12 – Updated: 2026-11-09 04:12
VLAI
EPSS
VEX
Summary
Improper Input Validation in the network communication processing in NEC Corporation WebSAM WinShare Ver 7.2.0 through 7.5.0, Ver 7.6.0 and Ver 7.7.0 through 7.7.2 on Windows allows a remote unauthenticated attacker to execute arbitrary commands with SYSTEM privileges via a crafted network packet sent to the computer on which WinShare is running.
Severity
CWE
- CWE-749 - Exposed dangerous method or function
Assigner
NEC
CNA
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| NEC Corporation | WebSAM WinShare |
Affected:
Ver 7.2.0 through 7.5.0, Ver 7.6.0 and Ver 7.7.0 through 7.7.2
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "WebSAM WinShare",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "Ver 7.2.0 through 7.5.0, Ver 7.6.0 and Ver 7.7.0 through 7.7.2"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "reported by Ruslan Sayfiev and Denis Faiustov of Fujitsu Limited, and Masahiro Kawada."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Input Validation in the network communication processing in NEC Corporation WebSAM WinShare Ver 7.2.0 through 7.5.0, Ver 7.6.0 and Ver 7.7.0 through 7.7.2 on Windows allows a remote unauthenticated attacker to execute arbitrary commands with SYSTEM privileges via a crafted network packet sent to the computer on which WinShare is running."
}
],
"value": "Improper Input Validation in the network communication processing in NEC Corporation WebSAM WinShare Ver 7.2.0 through 7.5.0, Ver 7.6.0 and Ver 7.7.0 through 7.7.2 on Windows allows a remote unauthenticated attacker to execute arbitrary commands with SYSTEM privileges via a crafted network packet sent to the computer on which WinShare is running."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-749",
"description": "CWE-749 Exposed dangerous method or function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T04:12:35.450Z",
"orgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
"shortName": "NEC"
},
"references": [
{
"url": "https://jpn.nec.com/security-info/secinfo/nv26-006_en.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
"assignerShortName": "NEC",
"cveId": "CVE-2026-113363",
"datePublished": "2026-11-09T04:12:35.450Z",
"dateReserved": "2026-10-20T01:52:26.266Z",
"dateUpdated": "2026-11-09T04:12:35.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-113362 (GCVE-0-2026-113362)
Vulnerability from cvelistv5 – Published: 2026-11-09 04:10 – Updated: 2026-11-09 04:10
VLAI
EPSS
VEX
Summary
Improper Access Control in the program installation folder in NEC Corporation WebSAM Winshare Ver 7.5.0 and earlier (excluding Ver 7.3.3), Ver 7.6.0 and Ver 7.7.0 through 7.7.1 on Windows allows a locally authenticated low-privileged attacker to execute arbitrary code with SYSTEM privileges via a crafted DLL file that is loaded by a SYSTEM-level process.
Severity
CWE
- CWE-276 - Incorrect default permissions in the Prob
Assigner
NEC
CNA
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| NEC Corporation | WebSAM WinShare |
Affected:
Ver 7.5.0 and earlier (excluding Ver 7.3.3), Ver 7.6.0 and Ver 7.7.0 through 7.7.1
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "WebSAM WinShare",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "Ver 7.5.0 and earlier (excluding Ver 7.3.3), Ver 7.6.0 and Ver 7.7.0 through 7.7.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "reported by Ruslan Sayfiev and Denis Faiustov of Fujitsu Limited, and Masahiro Kawada."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Access Control in the program installation folder in NEC Corporation WebSAM Winshare Ver 7.5.0 and earlier (excluding Ver 7.3.3), Ver 7.6.0 and Ver 7.7.0 through 7.7.1 on Windows allows a locally authenticated low-privileged attacker to execute arbitrary code with SYSTEM privileges via a crafted DLL file that is loaded by a SYSTEM-level process."
}
],
"value": "Improper Access Control in the program installation folder in NEC Corporation WebSAM Winshare Ver 7.5.0 and earlier (excluding Ver 7.3.3), Ver 7.6.0 and Ver 7.7.0 through 7.7.1 on Windows allows a locally authenticated low-privileged attacker to execute arbitrary code with SYSTEM privileges via a crafted DLL file that is loaded by a SYSTEM-level process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect default permissions in the Prob",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T04:10:22.553Z",
"orgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
"shortName": "NEC"
},
"references": [
{
"url": "https://jpn.nec.com/security-info/secinfo/nv26-006_en.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
"assignerShortName": "NEC",
"cveId": "CVE-2026-113362",
"datePublished": "2026-11-09T04:10:22.553Z",
"dateReserved": "2026-10-20T01:52:24.557Z",
"dateUpdated": "2026-11-09T04:10:22.553Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}