CVE-2026-95705 (GCVE-0-2026-95705)
Vulnerability from cvelistv5
Published
2026-10-22 19:06
Modified
2026-10-24 03:55
Severity ?
VLAI Severity ?
EPSS score ?
Summary
Command injection vulnerabilities in the affected interface of AOS-8 could allow an authenticated remote attacker with high privileges to perform command injection. Successful exploitation could allow an attacker to execute commands with the privileges of the impacted mechanism on the underlying operating system.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | ArubaOS (AOS) |
Version: 8.13.0.0 ≤ 8.13.3.0 Version: 8.10.0.0 ≤ 8.10.0.23 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-95705",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-23T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-24T03:55:33.153Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "ArubaOS (AOS)",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"lessThanOrEqual": "8.13.3.0",
"status": "affected",
"version": "8.13.0.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.10.0.23",
"status": "affected",
"version": "8.10.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "This vulnerability was reported by Michael Messner of Siemens Energy to HPE Networking."
}
],
"descriptions": [
{
"lang": "en",
"value": "Command injection vulnerabilities in the affected interface of AOS-8 could allow an authenticated remote attacker with high privileges to perform command injection. Successful exploitation could allow an attacker to execute commands with the privileges of the impacted mechanism on the underlying operating system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-23T19:14:03.133Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05162en_us\u0026docLocale=en_US"
}
],
"source": {
"advisory": "HPESBNW05162",
"discovery": "INTERNAL"
},
"title": "Authenticated Command Injection Vulnerabilities in AOS-8",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2026-95705",
"datePublished": "2026-10-22T19:06:52.111Z",
"dateReserved": "2026-09-22T14:51:39.865Z",
"dateUpdated": "2026-10-24T03:55:33.153Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-95705\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-10-23T17:21:28.548097Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-10-23T17:21:17.418Z\"}}], \"cna\": {\"title\": \"Authenticated Command Injection Vulnerabilities in AOS-8\", \"source\": {\"advisory\": \"HPESBNW05162\", \"discovery\": \"INTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"This vulnerability was reported by Michael Messner of Siemens Energy to HPE Networking.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Hewlett Packard Enterprise (HPE)\", \"product\": \"ArubaOS (AOS)\", \"versions\": [{\"status\": \"affected\", \"version\": \"8.13.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"8.13.3.0\"}, {\"status\": \"affected\", \"version\": \"8.10.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"8.10.0.23\"}], \"defaultStatus\": \"affected\"}], \"references\": [{\"url\": \"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05162en_us\u0026docLocale=en_US\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Command injection vulnerabilities in the affected interface of AOS-8 could allow an authenticated remote attacker with high privileges to perform command injection. Successful exploitation could allow an attacker to execute commands with the privileges of the impacted mechanism on the underlying operating system.\"}], \"providerMetadata\": {\"orgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"shortName\": \"hpe\", \"dateUpdated\": \"2026-10-23T19:14:03.133Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-95705\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-10-24T03:55:33.153Z\", \"dateReserved\": \"2026-09-22T14:51:39.865Z\", \"assignerOrgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"datePublished\": \"2026-10-22T19:06:52.111Z\", \"assignerShortName\": \"hpe\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…