CVE-2026-9397 (GCVE-0-2026-9397)

Vulnerability from cvelistv5 – Published: 2026-05-24 20:30 – Updated: 2026-05-26 14:37
VLAI
Title
Besen BS20 EV Charging Station OTA Update Installation improper authorization
Summary
A weakness has been identified in Besen BS20 EV Charging Station up to 20260426. Affected by this issue is some unknown functionality of the component OTA Update Installation Handler. This manipulation causes improper authorization. The attack is possible to be carried out remotely. A high degree of complexity is needed for the attack. The exploitation is known to be difficult. The original disclosure mentions, that "[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026."
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-26 14:37 UTC
CWE
  • CWE-285 - Improper Authorization
  • CWE-266 - Incorrect Privilege Assignment
Assigner
VulDB CNA
References
Impacted products
Vendor Product Version
Besen BS20 EV Charging Station Affected: 20260426
    cpe:2.3:a:besen:bs20_ev_charging_station:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9397",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-26T14:37:09.452464Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-26T14:37:21.762Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:besen:bs20_ev_charging_station:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "OTA Update Installation Handler"
          ],
          "product": "BS20 EV Charging Station",
          "vendor": "Besen",
          "versions": [
            {
              "status": "affected",
              "version": "20260426"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "carfeii (VulDB User)"
        },
        {
          "lang": "en",
          "type": "coordinator",
          "value": "VulDB CNA Team"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A weakness has been identified in Besen BS20 EV Charging Station up to 20260426. Affected by this issue is some unknown functionality of the component OTA Update Installation Handler. This manipulation causes improper authorization. The attack is possible to be carried out remotely. A high degree of complexity is needed for the attack. The exploitation is known to be difficult. The original disclosure mentions, that \"[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026.\""
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.2,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 7.6,
            "vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-285",
              "description": "Improper Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-266",
              "description": "Incorrect Privilege Assignment",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-24T20:30:10.350Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-365378 | Besen BS20 EV Charging Station OTA Update Installation improper authorization",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/vuln/365378"
        },
        {
          "name": "VDB-365378 | CTI Indicators (IOB, IOC, TTP)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/365378/cti"
        },
        {
          "name": "Submit #813576 | Besen EV Charging Station BS20 EV Charger Embedded Malicious Code",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/813576"
        },
        {
          "tags": [
            "patch"
          ],
          "url": "https://github.com/carfeii/besen#finding-4-unauthorized-firmware-installation-via-spoofed-ota-updates"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-24T08:24:17.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Besen BS20 EV Charging Station OTA Update Installation improper authorization"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-9397",
    "datePublished": "2026-05-24T20:30:10.350Z",
    "dateReserved": "2026-05-24T06:19:00.635Z",
    "dateUpdated": "2026-05-26T14:37:21.762Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9397",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-26T14:37:09.452464Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-26T14:37:16.375Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:a:besen:bs20_ev_charging_station:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "OTA Update Installation Handler"
              ],
              "product": "BS20 EV Charging Station",
              "vendor": "Besen",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260426"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "carfeii (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Besen BS20 EV Charging Station up to 20260426. Affected by this issue is some unknown functionality of the component OTA Update Installation Handler. This manipulation causes improper authorization. The attack is possible to be carried out remotely. A high degree of complexity is needed for the attack. The exploitation is known to be difficult. The original disclosure mentions, that \"[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026.\""
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 7.6,
                "vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-285",
                  "description": "Improper Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "Incorrect Privilege Assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-24T20:30:10.350Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-365378 | Besen BS20 EV Charging Station OTA Update Installation improper authorization",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/vuln/365378"
            },
            {
              "name": "VDB-365378 | CTI Indicators (IOB, IOC, TTP)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/365378/cti"
            },
            {
              "name": "Submit #813576 | Besen EV Charging Station BS20 EV Charger Embedded Malicious Code",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/813576"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://github.com/carfeii/besen#finding-4-unauthorized-firmware-installation-via-spoofed-ota-updates"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-05-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-05-24T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-05-24T08:24:17.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Besen BS20 EV Charging Station OTA Update Installation improper authorization"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-9397",
        "datePublished": "2026-05-24T20:30:10.350Z",
        "dateReserved": "2026-05-24T06:19:00.635Z",
        "dateUpdated": "2026-05-26T14:37:21.762Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.