CVE-2026-87674 (GCVE-0-2026-87674)
Vulnerability from cvelistv5
Published
2026-10-08 03:31
Modified
2026-10-09 03:55
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A local privilege escalation vulnerability exists in the system logging daemon of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. Insufficient access controls on internal inter-process communication (IPC) channels allow an unprivileged local user to submit malformed logging configurations. Due to improper input sanitization during configuration file generation, an attacker can inject arbitrary directives that execute with elevated privileges when the logging service reloads, leading to local privilege escalation.
References
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-87674",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-08T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-09T03:55:38.551Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Fabric OS",
"vendor": "Brocade",
"versions": [
{
"lessThan": "9.2.2d",
"status": "affected",
"version": "0",
"versionType": "Brocade FabricOS"
},
{
"lessThanOrEqual": "10.0.0a1",
"status": "affected",
"version": "10.0.0",
"versionType": "Brocade FabricOS"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA local privilege escalation vulnerability exists in the system logging daemon of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. Insufficient access controls on internal inter-process communication (IPC) channels allow an unprivileged local user to submit malformed logging configurations. Due to improper input sanitization during configuration file generation, an attacker can inject arbitrary directives that execute with elevated privileges when the logging service reloads, leading to local privilege escalation.\u003c/p\u003e"
}
],
"value": "A local privilege escalation vulnerability exists in the system logging daemon of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. Insufficient access controls on internal inter-process communication (IPC) channels allow an unprivileged local user to submit malformed logging configurations. Due to improper input sanitization during configuration file generation, an attacker can inject arbitrary directives that execute with elevated privileges when the logging service reloads, leading to local privilege escalation."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-08T03:31:26.439Z",
"orgId": "87b297d7-335e-4844-9551-11b97995a791",
"shortName": "brocade"
},
"references": [
{
"url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/39145"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eSecurity update is provided in Brocade Fabric OS 9.2.2d and 10.0.1\u003c/div\u003e"
}
],
"value": "Security update is provided in Brocade Fabric OS 9.2.2d and 10.0.1"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
"assignerShortName": "brocade",
"cveId": "CVE-2026-87674",
"datePublished": "2026-10-08T03:31:26.439Z",
"dateReserved": "2026-09-08T22:51:12.166Z",
"dateUpdated": "2026-10-09T03:55:38.551Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-87674\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-10-08T13:11:30.735648Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-10-08T13:12:06.243Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-88\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-88 OS Command Injection\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.5, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Brocade\", \"product\": \"Fabric OS\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"9.2.2d\", \"versionType\": \"Brocade FabricOS\"}, {\"status\": \"affected\", \"version\": \"10.0.0\", \"versionType\": \"Brocade FabricOS\", \"lessThanOrEqual\": \"10.0.0a1\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Security update is provided in Brocade Fabric OS 9.2.2d and 10.0.1\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cdiv\u003eSecurity update is provided in Brocade Fabric OS 9.2.2d and 10.0.1\u003c/div\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://support.broadcom.com/external/content/SecurityAdvisories/0/39145\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.5\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A local privilege escalation vulnerability exists in the system logging daemon of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. Insufficient access controls on internal inter-process communication (IPC) channels allow an unprivileged local user to submit malformed logging configurations. Due to improper input sanitization during configuration file generation, an attacker can inject arbitrary directives that execute with elevated privileges when the logging service reloads, leading to local privilege escalation.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eA local privilege escalation vulnerability exists in the system logging daemon of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. Insufficient access controls on internal inter-process communication (IPC) channels allow an unprivileged local user to submit malformed logging configurations. Due to improper input sanitization during configuration file generation, an attacker can inject arbitrary directives that execute with elevated privileges when the logging service reloads, leading to local privilege escalation.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"87b297d7-335e-4844-9551-11b97995a791\", \"shortName\": \"brocade\", \"dateUpdated\": \"2026-10-08T03:31:26.439Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-87674\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-10-09T03:55:38.551Z\", \"dateReserved\": \"2026-09-08T22:51:12.166Z\", \"assignerOrgId\": \"87b297d7-335e-4844-9551-11b97995a791\", \"datePublished\": \"2026-10-08T03:31:26.439Z\", \"assignerShortName\": \"brocade\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…