CVE-2026-84941 (GCVE-0-2026-84941)
Vulnerability from cvelistv5
Published
2026-09-10 23:35
Modified
2026-09-11 13:16
CWE
  • CWE-611 - Improper restriction of XML external entity reference
Summary
An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-84941",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-11T13:10:27.244979Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-11T13:16:12.359Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "Omada Software Controller (Windows)",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "6.2.14.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "Omada Software Controller (Linux)",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "6.2.14.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC2000 v1",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "1.41.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC2000 v2",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "2.26.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC200 v3",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "3.3.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC220 v1",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "1.6.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC220 v2",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "2.5.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC300 v1",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "1.35.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC400 v1",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "1.13.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "erikdejong"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "mattgsys"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "eslam moneer (tohtmosiii)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003eAn information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.\u003c/div\u003e"
            }
          ],
          "value": "An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-221",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-221 Data Serialization External Entities Blowup"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "CWE-611 Improper restriction of XML external entity reference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-10T23:35:53.023Z",
        "orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
        "shortName": "TPLink"
      },
      "references": [
        {
          "tags": [
            "patch"
          ],
          "url": "https://support.omadanetworks.com/en/download/software/omada-controller"
        },
        {
          "tags": [
            "patch"
          ],
          "url": "https://support.omadanetworks.com/us/download/software/omada-controller"
        },
        {
          "tags": [
            "patch"
          ],
          "url": "https://www.omadanetworks.com/en/support/download/"
        },
        {
          "tags": [
            "patch"
          ],
          "url": "https://www.omadanetworks.com/us/support/download/"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://support.omadanetworks.com/en/document/133722/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
    "assignerShortName": "TPLink",
    "cveId": "CVE-2026-84941",
    "datePublished": "2026-09-10T23:35:53.023Z",
    "dateReserved": "2026-09-02T16:45:11.015Z",
    "dateUpdated": "2026-09-11T13:16:12.359Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-84941\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-09-11T13:10:27.244979Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-09-11T13:16:06.612Z\"}}], \"cna\": {\"title\": \"Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"erikdejong\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"mattgsys\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"eslam moneer (tohtmosiii)\"}], \"impacts\": [{\"capecId\": \"CAPEC-221\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-221 Data Serialization External Entities Blowup\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 6.9, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"TP-Link Systems Inc.\", \"product\": \"Omada Software Controller (Windows)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"6.2.14.11\", \"versionType\": \"custom\"}], \"platforms\": [\"Omada Controller\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"TP-Link Systems Inc.\", \"product\": \"Omada Software Controller (Linux)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"6.2.14.11\", \"versionType\": \"custom\"}], \"platforms\": [\"Omada Controller\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"TP-Link Systems Inc.\", \"product\": \"OC2000 v1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.41.11 Build 20260711\", \"versionType\": \"custom\"}], \"platforms\": [\"Omada Controller\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"TP-Link Systems Inc.\", \"product\": \"OC2000 v2\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.26.11 Build 20260711\", \"versionType\": \"custom\"}], \"platforms\": [\"Omada Controller\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"TP-Link Systems Inc.\", \"product\": \"OC200 v3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.3.11 Build 20260711\", \"versionType\": \"custom\"}], \"platforms\": [\"Omada Controller\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"TP-Link Systems Inc.\", \"product\": \"OC220 v1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.6.11 Build 20260711\", \"versionType\": \"custom\"}], \"platforms\": [\"Omada Controller\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"TP-Link Systems Inc.\", \"product\": \"OC220 v2\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.5.11 Build 20260711\", \"versionType\": \"custom\"}], \"platforms\": [\"Omada Controller\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"TP-Link Systems Inc.\", \"product\": \"OC300 v1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.35.11 Build 20260711\", \"versionType\": \"custom\"}], \"platforms\": [\"Omada Controller\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"TP-Link Systems Inc.\", \"product\": \"OC400 v1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.13.11 Build 20260711\", \"versionType\": \"custom\"}], \"platforms\": [\"Omada Controller\"], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://support.omadanetworks.com/en/download/software/omada-controller\", \"tags\": [\"patch\"]}, {\"url\": \"https://support.omadanetworks.com/us/download/software/omada-controller\", \"tags\": [\"patch\"]}, {\"url\": \"https://www.omadanetworks.com/en/support/download/\", \"tags\": [\"patch\"]}, {\"url\": \"https://www.omadanetworks.com/us/support/download/\", \"tags\": [\"patch\"]}, {\"url\": \"https://support.omadanetworks.com/en/document/133722/\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.5\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cdiv\u003eAn information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.\u003c/div\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-611\", \"description\": \"CWE-611 Improper restriction of XML external entity reference\"}]}], \"providerMetadata\": {\"orgId\": \"f23511db-6c3e-4e32-a477-6aa17d310630\", \"shortName\": \"TPLink\", \"dateUpdated\": \"2026-09-10T23:35:53.023Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-84941\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-09-11T13:16:12.359Z\", \"dateReserved\": \"2026-09-02T16:45:11.015Z\", \"assignerOrgId\": \"f23511db-6c3e-4e32-a477-6aa17d310630\", \"datePublished\": \"2026-09-10T23:35:53.023Z\", \"assignerShortName\": \"TPLink\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…