CVE-2026-84400 (GCVE-0-2026-84400)
Vulnerability from cvelistv5
Published
2026-09-18 16:10
Modified
2026-09-19 14:11
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CareCam | HMT.CM2507 Firmware |
Version: v251211.1507 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-84400",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-19T13:44:30.475992Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-19T14:11:43.861Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "HMT.CM2507 Firmware",
"vendor": "CareCam",
"versions": [
{
"status": "affected",
"version": "v251211.1507"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ben Law reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access."
}
],
"value": "CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.1,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 2.3,
"baseSeverity": "LOW",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-18T16:10:28.768Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-08"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-08.json"
}
],
"source": {
"advisory": "ICSA-26-258-08",
"discovery": "EXTERNAL"
},
"title": "CareCam CM2507 Missing Authentication for Critical Function",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CareCam has not responded to CISA\u0027s attempts to coordinate. Users are encouraged to reach out to CareCam for more information."
}
],
"value": "CareCam has not responded to CISA\u0027s attempts to coordinate. Users are encouraged to reach out to CareCam for more information."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-84400",
"datePublished": "2026-09-18T16:10:28.768Z",
"dateReserved": "2026-09-10T15:00:49.635Z",
"dateUpdated": "2026-09-19T14:11:43.861Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-84400\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-09-19T13:44:30.475992Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-09-19T14:11:02.385Z\"}}], \"cna\": {\"title\": \"CareCam CM2507 Missing Authentication for Critical Function\", \"source\": {\"advisory\": \"ICSA-26-258-08\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Ben Law reported this vulnerability to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 3.1, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"LOW\", \"vectorString\": \"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 2.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"LOW\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"PRESENT\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"LOW\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"CareCam\", \"product\": \"HMT.CM2507 Firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"v251211.1507\"}], \"defaultStatus\": \"affected\"}], \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-08\"}, {\"url\": \"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-08.json\"}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"CareCam has not responded to CISA\u0027s attempts to coordinate. Users are encouraged to reach out to CareCam for more information.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"CareCam has not responded to CISA\u0027s attempts to coordinate. Users are encouraged to reach out to CareCam for more information.\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.5\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2026-09-18T16:10:28.768Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-84400\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-09-19T14:11:43.861Z\", \"dateReserved\": \"2026-09-10T15:00:49.635Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2026-09-18T16:10:28.768Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…