CVE-2026-82595 (GCVE-0-2026-82595)
Vulnerability from cvelistv5
Published
2026-08-30 23:45
Modified
2026-08-31 22:04
CWE
Summary
A vulnerability was found in D-Link DIR-825M 1.1.8. Affected by this vulnerability is the function sub_456CF4 of the file /boafrm/formSysCmd of the component System Command Execution. Performing a manipulation of the argument sysCmd results in command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used.
Impacted products
Vendor Product Version
D-Link DIR-825M Version: 1.1.8
    cpe:2.3:h:d-link:dir-825m:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-82595",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-31T21:50:27.759732Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-31T22:04:06.409Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:d-link:dir-825m:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "System Command Execution"
          ],
          "product": "DIR-825M",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "1.1.8"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "hacker128 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in D-Link DIR-825M 1.1.8. Affected by this vulnerability is the function sub_456CF4 of the file /boafrm/formSysCmd of the component System Command Execution. Performing a manipulation of the argument sysCmd results in command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-30T23:45:08.885Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-397090 | D-Link DIR-825M System Command Execution formSysCmd sub_456CF4 command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/397090"
        },
        {
          "name": "VDB-397090 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/397090/cti"
        },
        {
          "name": "CVE-2026-82595 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-82595"
        },
        {
          "name": "Submit #892630 | D-Link DIR-825M v1.1.8 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/892630"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Dlink/formSysCmd/formSysCmd.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-08-30T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-08-30T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-08-30T08:28:08.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DIR-825M System Command Execution formSysCmd sub_456CF4 command injection",
      "x_generator": [
        "VulDB PVTS v202608"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-82595",
    "datePublished": "2026-08-30T23:45:08.885Z",
    "dateReserved": "2026-08-30T06:23:02.334Z",
    "dateUpdated": "2026-08-31T22:04:06.409Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-82595\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-08-31T21:50:27.759732Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-08-31T21:50:28.718Z\"}}], \"cna\": {\"title\": \"D-Link DIR-825M System Command Execution formSysCmd sub_456CF4 command injection\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"hacker128 (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.4, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 7.4, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 6.5, \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:d-link:dir-825m:*:*:*:*:*:*:*:*\"], \"vendor\": \"D-Link\", \"modules\": [\"System Command Execution\"], \"product\": \"DIR-825M\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.1.8\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2026-08-30T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2026-08-30T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2026-08-30T08:28:08.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/vuln/397090\", \"name\": \"VDB-397090 | D-Link DIR-825M System Command Execution formSysCmd sub_456CF4 command injection\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/vuln/397090/cti\", \"name\": \"VDB-397090 | CTI Indicators (IOB, IOC, TTP, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/cve/CVE-2026-82595\", \"name\": \"CVE-2026-82595 | CVE Analysis and Report\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://vuldb.com/submit/892630\", \"name\": \"Submit #892630 | D-Link DIR-825M v1.1.8 Command Injection\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/Robots10/IoT_vlu/blob/main/reports/Dlink/formSysCmd/formSysCmd.md\", \"tags\": [\"exploit\"]}, {\"url\": \"https://www.dlink.com/\", \"tags\": [\"product\"]}], \"x_generator\": [\"VulDB PVTS v202608\"], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was found in D-Link DIR-825M 1.1.8. Affected by this vulnerability is the function sub_456CF4 of the file /boafrm/formSysCmd of the component System Command Execution. Performing a manipulation of the argument sysCmd results in command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"Command Injection\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-74\", \"description\": \"Injection\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2026-08-30T23:45:08.885Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-82595\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-08-31T22:04:06.409Z\", \"dateReserved\": \"2026-08-30T06:23:02.334Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2026-08-30T23:45:08.885Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.