CVE-2026-80154 (GCVE-0-2026-80154)
Vulnerability from cvelistv5
Published
2026-09-22 15:22
Modified
2026-09-24 19:10
Severity ?
8.9 (High) - CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
9.6 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
9.6 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-330 - Use of Insufficiently Random Values
Summary
All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80154",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T17:22:31.916185Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T17:44:14.925Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 8.9,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-330",
"description": "Use of Insufficiently Random Values",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:10:15.088Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-predictable-session-token-with-validation-bypass"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices Predictable Session Token with Validation Bypass",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80154",
"datePublished": "2026-09-22T15:22:33.748Z",
"dateReserved": "2026-08-25T20:43:54.262Z",
"dateUpdated": "2026-09-24T19:10:15.088Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-80154\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-09-22T17:22:31.916185Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-09-22T17:23:29.168Z\"}}], \"cna\": {\"title\": \"Lantronix Autonomous Out-of-Band Devices Predictable Session Token with Validation Bypass\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"RE/VRb\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.9, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"ACTIVE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"PRESENT\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"HIGH\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 9.6, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"LANTRONIX\", \"product\": \"SLC8000\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"LANTRONIX\", \"product\": \"EMG8500\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"LANTRONIX\", \"product\": \"EMG7500\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"LANTRONIX\", \"product\": \"SLB882\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"LANTRONIX\", \"product\": \"SLCx-03\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"LANTRONIX\", \"product\": \"SLCx-02\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"LANTRONIX\", \"product\": \"SLC9000\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2026-09-18T00:00:00.000Z\", \"references\": [{\"url\": \"https://revrb.net/2026/09/21/revrb-lantern.html\", \"name\": \"Researcher Disclosure\", \"tags\": [\"technical-description\"]}, {\"url\": \"https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-predictable-session-token-with-validation-bypass\", \"tags\": [\"third-party-advisory\"]}], \"x_generator\": {\"engine\": \"vulncheck\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-330\", \"description\": \"Use of Insufficiently Random Values\"}]}], \"providerMetadata\": {\"orgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"shortName\": \"VulnCheck\", \"dateUpdated\": \"2026-09-24T19:10:15.088Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-80154\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-09-24T19:10:15.088Z\", \"dateReserved\": \"2026-08-25T20:43:54.262Z\", \"assignerOrgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"datePublished\": \"2026-09-22T15:22:33.748Z\", \"assignerShortName\": \"VulnCheck\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…