CVE-2026-80147 (GCVE-0-2026-80147)
Vulnerability from cvelistv5
Published
2026-09-22 15:20
Modified
2026-09-24 19:04
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-80147",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-22T16:02:05.783698Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-22T16:04:04.161Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SLC8000",
          "vendor": "LANTRONIX",
          "versions": [
            {
              "lessThan": "9.7.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EMG8500",
          "vendor": "LANTRONIX",
          "versions": [
            {
              "lessThan": "9.7.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EMG7500",
          "vendor": "LANTRONIX",
          "versions": [
            {
              "lessThan": "9.7.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SLB882",
          "vendor": "LANTRONIX",
          "versions": [
            {
              "status": "affected",
              "version": "*",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SLCx-03",
          "vendor": "LANTRONIX",
          "versions": [
            {
              "status": "affected",
              "version": "*",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SLCx-02",
          "vendor": "LANTRONIX",
          "versions": [
            {
              "status": "affected",
              "version": "*",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SLC9000",
          "vendor": "LANTRONIX",
          "versions": [
            {
              "lessThan": "9.7.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "RE/VRb"
        }
      ],
      "datePublic": "2026-09-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-24T19:04:09.218Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "name": "Researcher Disclosure",
          "tags": [
            "technical-description"
          ],
          "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
        },
        {
          "name": "SLC8000 Firmware",
          "tags": [
            "patch"
          ],
          "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
        },
        {
          "name": "EMG8500 Firmware",
          "tags": [
            "patch"
          ],
          "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
        },
        {
          "name": "EMG7500 Firmware",
          "tags": [
            "patch"
          ],
          "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
        },
        {
          "name": "SLC9000 Firmware",
          "tags": [
            "patch"
          ],
          "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-write"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom write",
      "x_generator": {
        "engine": "vulncheck"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2026-80147",
    "datePublished": "2026-09-22T15:20:01.691Z",
    "dateReserved": "2026-08-25T20:43:54.261Z",
    "dateUpdated": "2026-09-24T19:04:09.218Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-80147\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-09-22T16:02:05.783698Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-09-22T16:03:58.461Z\"}}], \"cna\": {\"title\": \"Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom write\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"RE/VRb\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 9.4, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"HIGH\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 9.9, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"LANTRONIX\", \"product\": \"SLC8000\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"9.7.0.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"LANTRONIX\", \"product\": \"EMG8500\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"9.7.0.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"LANTRONIX\", \"product\": \"EMG7500\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"9.7.0.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"LANTRONIX\", \"product\": \"SLB882\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"LANTRONIX\", \"product\": \"SLCx-03\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"LANTRONIX\", \"product\": \"SLCx-02\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"LANTRONIX\", \"product\": \"SLC9000\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"9.7.0.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2026-09-18T00:00:00.000Z\", \"references\": [{\"url\": \"https://revrb.net/2026/09/21/revrb-lantern.html\", \"name\": \"Researcher Disclosure\", \"tags\": [\"technical-description\"]}, {\"url\": \"https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/\", \"name\": \"SLC8000 Firmware\", \"tags\": [\"patch\"]}, {\"url\": \"https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/\", \"name\": \"EMG8500 Firmware\", \"tags\": [\"patch\"]}, {\"url\": \"https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/\", \"name\": \"EMG7500 Firmware\", \"tags\": [\"patch\"]}, {\"url\": \"https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/\", \"name\": \"SLC9000 Firmware\", \"tags\": [\"patch\"]}, {\"url\": \"https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-write\", \"tags\": [\"third-party-advisory\"]}], \"x_generator\": {\"engine\": \"vulncheck\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"Stack-based Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"shortName\": \"VulnCheck\", \"dateUpdated\": \"2026-09-24T19:04:09.218Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-80147\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-09-24T19:04:09.218Z\", \"dateReserved\": \"2026-08-25T20:43:54.261Z\", \"assignerOrgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"datePublished\": \"2026-09-22T15:20:01.691Z\", \"assignerShortName\": \"VulnCheck\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…