CVE-2026-77551 (GCVE-0-2026-77551)
Vulnerability from cvelistv5
Published
2026-08-26 10:37
Modified
2026-08-26 12:49
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-284 - Improper Access Control - Generic
Summary
A malicious actor with access to the network and under certain conditions could exploit an Improper Access Control vulnerability found in UniFi Connect Display Cast Pro to escalate privileges on the device.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ubiquiti Inc | UniFi Connect Display Cast Pro |
Version: 0 ≤ |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-77551",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-26T12:49:40.158407Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T12:49:50.559Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Connect Display Cast Pro",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.0.111",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A malicious actor with access to the network and under certain conditions could exploit an Improper Access Control vulnerability found in UniFi Connect Display Cast Pro to escalate privileges on the device."
}
],
"value": "A malicious actor with access to the network and under certain conditions could exploit an Improper Access Control vulnerability found in UniFi Connect Display Cast Pro to escalate privileges on the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control - Generic",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T10:37:19.573Z",
"orgId": "fe490ce8-0395-4072-90d8-2707e1bdf984",
"shortName": "Ubiquiti"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-067/fc4a3488-7c43-4628-8bab-f715e96dbfc9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "fe490ce8-0395-4072-90d8-2707e1bdf984",
"assignerShortName": "Ubiquiti",
"cveId": "CVE-2026-77551",
"datePublished": "2026-08-26T10:37:19.573Z",
"dateReserved": "2026-08-20T20:32:37.794Z",
"dateUpdated": "2026-08-26T12:49:50.559Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-77551\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-08-26T12:49:40.158407Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-08-26T12:49:47.631Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 9, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Ubiquiti Inc\", \"product\": \"UniFi Connect Display Cast Pro\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.0.111\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://community.ui.com/releases/Security-Advisory-Bulletin-067/fc4a3488-7c43-4628-8bab-f715e96dbfc9\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.5\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A malicious actor with access to the network and under certain conditions could exploit an Improper Access Control vulnerability found in UniFi Connect Display Cast Pro to escalate privileges on the device.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A malicious actor with access to the network and under certain conditions could exploit an Improper Access Control vulnerability found in UniFi Connect Display Cast Pro to escalate privileges on the device.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284 Improper Access Control - Generic\"}]}], \"providerMetadata\": {\"orgId\": \"fe490ce8-0395-4072-90d8-2707e1bdf984\", \"shortName\": \"Ubiquiti\", \"dateUpdated\": \"2026-08-26T10:37:19.573Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-77551\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-08-26T12:49:50.559Z\", \"dateReserved\": \"2026-08-20T20:32:37.794Z\", \"assignerOrgId\": \"fe490ce8-0395-4072-90d8-2707e1bdf984\", \"datePublished\": \"2026-08-26T10:37:19.573Z\", \"assignerShortName\": \"Ubiquiti\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…