CVE-2026-76724 (GCVE-0-2026-76724)
Vulnerability from cvelistv5
Published
2026-09-29 19:28
Modified
2026-10-01 03:55
Severity ?
VLAI Severity ?
EPSS score ?
Summary
A command injection vulnerability exists in CLI of the affected HPE Networking Instant ON APs that could allow an unauthenticated adjacent attacker to perform command injection by sending specially crafted packets. Successful exploitation could allow an attacker to execute arbitrary commands as a privileged user on the underlying operating system.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | Instant ON |
Version: 0.0.0.0 ≤ 3.4.1.0 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-76724",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-30T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-01T03:55:32.992Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "Instant ON",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"lessThanOrEqual": "3.4.1.0",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Internal security research (HPE Networking)."
}
],
"descriptions": [
{
"lang": "en",
"value": "A command injection vulnerability exists in CLI of the affected HPE Networking Instant ON APs that could allow an unauthenticated adjacent attacker to perform command injection by sending specially crafted packets. Successful exploitation could allow an attacker to execute arbitrary commands as a privileged user on the underlying operating system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-29T19:28:37.681Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05150en_us\u0026docLocale=en_US"
}
],
"source": {
"advisory": "HPESBNW05150",
"discovery": "INTERNAL"
},
"title": "Unauthenticated Adjacent Command Injection Vulnerability in HPE Networking Instant ON APs Command Line Interface (CLI) Accessed by the PAPI Protocol",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2026-76724",
"datePublished": "2026-09-29T19:28:37.681Z",
"dateReserved": "2026-08-19T16:12:51.872Z",
"dateUpdated": "2026-10-01T03:55:32.992Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-76724\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-09-30T18:27:20.188985Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-09-30T18:27:30.832Z\"}}], \"cna\": {\"title\": \"Unauthenticated Adjacent Command Injection Vulnerability in HPE Networking Instant ON APs Command Line Interface (CLI) Accessed by the PAPI Protocol\", \"source\": {\"advisory\": \"HPESBNW05150\", \"discovery\": \"INTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"Internal security research (HPE Networking).\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 9.6, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Hewlett Packard Enterprise (HPE)\", \"product\": \"Instant ON\", \"versions\": [{\"status\": \"affected\", \"version\": \"0.0.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"3.4.1.0\"}], \"defaultStatus\": \"affected\"}], \"references\": [{\"url\": \"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05150en_us\u0026docLocale=en_US\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A command injection vulnerability exists in CLI of the affected HPE Networking Instant ON APs that could allow an unauthenticated adjacent attacker to perform command injection by sending specially crafted packets. Successful exploitation could allow an attacker to execute arbitrary commands as a privileged user on the underlying operating system.\"}], \"providerMetadata\": {\"orgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"shortName\": \"hpe\", \"dateUpdated\": \"2026-09-29T19:28:37.681Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-76724\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-10-01T03:55:32.992Z\", \"dateReserved\": \"2026-08-19T16:12:51.872Z\", \"assignerOrgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"datePublished\": \"2026-09-29T19:28:37.681Z\", \"assignerShortName\": \"hpe\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…