CVE-2026-71396 (GCVE-0-2026-71396)
Vulnerability from cvelistv5
Published
2026-08-27 20:45
Modified
2026-08-28 15:57
CWE
  • CWE-798 - Use of Hard-coded Credentials
Summary
Bendix EC80 Brake ECU uses hard-coded credentials, which could allow an attacker to disable automatic traction control.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-71396",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-28T15:49:02.909444Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-28T15:57:46.738Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EC80ESP+ J1708",
          "vendor": "Bendix",
          "versions": [
            {
              "status": "affected",
              "version": "Z228999"
            },
            {
              "status": "unaffected",
              "version": "Z300822"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EC80ESP+ 6S/6M",
          "vendor": "Bendix",
          "versions": [
            {
              "status": "affected",
              "version": "Z228999"
            },
            {
              "status": "unaffected",
              "version": "Z300822"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EC80ESP+ PLC",
          "vendor": "Bendix",
          "versions": [
            {
              "status": "affected",
              "version": "Z228999"
            },
            {
              "status": "unaffected",
              "version": "Z300822"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EC80ESP+ 2nd CAN",
          "vendor": "Bendix",
          "versions": [
            {
              "status": "affected",
              "version": "Z228999"
            },
            {
              "status": "unaffected",
              "version": "Z300822"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EC80ESP+ Integrated TPMS",
          "vendor": "Bendix",
          "versions": [
            {
              "status": "affected",
              "version": "Z228999"
            },
            {
              "status": "unaffected",
              "version": "Z300822"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EC80ESP 6S/6M",
          "vendor": "Bendix",
          "versions": [
            {
              "status": "affected",
              "version": "Z266494"
            },
            {
              "status": "unaffected",
              "version": "Z302578"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EC80ESP PLC",
          "vendor": "Bendix",
          "versions": [
            {
              "status": "affected",
              "version": "Z266494"
            },
            {
              "status": "unaffected",
              "version": "Z302578"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EC80ESP 2nd CAN",
          "vendor": "Bendix",
          "versions": [
            {
              "status": "affected",
              "version": "Z266494"
            },
            {
              "status": "unaffected",
              "version": "Z302578"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EC80ESP CAN Gateway",
          "vendor": "Bendix",
          "versions": [
            {
              "status": "affected",
              "version": "Z266494"
            },
            {
              "status": "unaffected",
              "version": "Z302578"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EC80ESP 4S/4M",
          "vendor": "Bendix",
          "versions": [
            {
              "status": "affected",
              "version": "Z286098"
            },
            {
              "status": "unaffected",
              "version": "Z302579"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EC80ESP PLC",
          "vendor": "Bendix",
          "versions": [
            {
              "status": "affected",
              "version": "Z286098"
            },
            {
              "status": "unaffected",
              "version": "Z302579"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Ben Gardiner of NMFTA reported this vulnerability to CISA."
        }
      ],
      "datePublic": "2026-08-25T14:28:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Bendix EC80 Brake ECU\u0026nbsp;uses hard-coded credentials, which could allow an attacker to disable automatic traction control."
            }
          ],
          "value": "Bendix EC80 Brake ECU\u00a0uses hard-coded credentials, which could allow an attacker to disable automatic traction control."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-27T20:45:52.804Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-05"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-237-05.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.\u003cdiv\u003e\u003cul\u003e\u003cli\u003eEC80ESP+ J1708: Users should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ 6S/6M:\u0026nbsp;Users\n\n\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ PLC:\u0026nbsp;Users\u0026nbsp;\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ 2nd CAN:\nUsers\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ Integrated TPMS:\u0026nbsp;Users\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP 6S/6M:\nUsers\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP 2nd CAN:\nUsers\n\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP CAN Gateway:\nUsers\n\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP 4S/4M:\nUsers\n\nshould update their firmware to version Z302579.\u003c/li\u003e\u003cli\u003eEC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302579.\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e"
            }
          ],
          "value": "Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.  *  EC80ESP+ J1708: Users should update their firmware to version Z300822.\n  *  EC80ESP+ 6S/6M:\u00a0Users\n\n\u00a0should update their firmware to version Z300822.\n  *  EC80ESP+ PLC:\u00a0Users\u00a0\u00a0should update their firmware to version Z300822.\n  *  EC80ESP+ 2nd CAN:\nUsers\u00a0should update their firmware to version Z300822.\n  *  EC80ESP+ Integrated TPMS:\u00a0Users\u00a0should update their firmware to version Z300822.\n  *  EC80ESP 6S/6M:\nUsers\nshould update their firmware to version Z302578.\n  *  EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302578.\n  *  EC80ESP 2nd CAN:\nUsers\n\nshould update their firmware to version Z302578.\n  *  EC80ESP CAN Gateway:\nUsers\n\nshould update their firmware to version Z302578.\n  *  EC80ESP 4S/4M:\nUsers\n\nshould update their firmware to version Z302579.\n  *  EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302579."
        }
      ],
      "source": {
        "advisory": "ICSA-26-237-05",
        "discovery": "EXTERNAL"
      },
      "title": "Use of Hard-coded Credentials in Bendix EC80 Brake ECU",
      "x_generator": {
        "engine": "Vulnogram 1.0.4"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-71396",
    "datePublished": "2026-08-27T20:45:52.804Z",
    "dateReserved": "2026-08-10T16:03:40.501Z",
    "dateUpdated": "2026-08-28T15:57:46.738Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"cna\": {\"title\": \"Use of Hard-coded Credentials in Bendix EC80 Brake ECU\", \"source\": {\"advisory\": \"ICSA-26-237-05\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Ben Gardiner of NMFTA reported this vulnerability to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.4, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 5.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"LOW\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"LOW\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ J1708\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ 6S/6M\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ PLC\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ 2nd CAN\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ Integrated TPMS\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP 6S/6M\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z266494\"}, {\"status\": \"unaffected\", \"version\": \"Z302578\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP PLC\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z266494\"}, {\"status\": \"unaffected\", \"version\": \"Z302578\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP 2nd CAN\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z266494\"}, {\"status\": \"unaffected\", \"version\": \"Z302578\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP CAN Gateway\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z266494\"}, {\"status\": \"unaffected\", \"version\": \"Z302578\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP 4S/4M\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z286098\"}, {\"status\": \"unaffected\", \"version\": \"Z302579\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP PLC\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z286098\"}, {\"status\": \"unaffected\", \"version\": \"Z302579\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.  *  EC80ESP+ J1708: Users should update their firmware to version Z300822.\\n  *  EC80ESP+ 6S/6M:\\u00a0Users\\n\\n\\u00a0should update their firmware to version Z300822.\\n  *  EC80ESP+ PLC:\\u00a0Users\\u00a0\\u00a0should update their firmware to version Z300822.\\n  *  EC80ESP+ 2nd CAN:\\nUsers\\u00a0should update their firmware to version Z300822.\\n  *  EC80ESP+ Integrated TPMS:\\u00a0Users\\u00a0should update their firmware to version Z300822.\\n  *  EC80ESP 6S/6M:\\nUsers\\nshould update their firmware to version Z302578.\\n  *  EC80ESP PLC:\\nUsers\\n\\nshould update their firmware to version Z302578.\\n  *  EC80ESP 2nd CAN:\\nUsers\\n\\nshould update their firmware to version Z302578.\\n  *  EC80ESP CAN Gateway:\\nUsers\\n\\nshould update their firmware to version Z302578.\\n  *  EC80ESP 4S/4M:\\nUsers\\n\\nshould update their firmware to version Z302579.\\n  *  EC80ESP PLC:\\nUsers\\n\\nshould update their firmware to version Z302579.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.\u003cdiv\u003e\u003cul\u003e\u003cli\u003eEC80ESP+ J1708: Users should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ 6S/6M:\u0026nbsp;Users\\n\\n\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ PLC:\u0026nbsp;Users\u0026nbsp;\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ 2nd CAN:\\nUsers\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ Integrated TPMS:\u0026nbsp;Users\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP 6S/6M:\\nUsers\\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP PLC:\\nUsers\\n\\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP 2nd CAN:\\nUsers\\n\\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP CAN Gateway:\\nUsers\\n\\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP 4S/4M:\\nUsers\\n\\nshould update their firmware to version Z302579.\u003c/li\u003e\u003cli\u003eEC80ESP PLC:\\nUsers\\n\\nshould update their firmware to version Z302579.\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\", \"base64\": false}]}], \"datePublic\": \"2026-08-25T14:28:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-05\"}, {\"url\": \"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-237-05.json\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.4\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Bendix EC80 Brake ECU\\u00a0uses hard-coded credentials, which could allow an attacker to disable automatic traction control.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Bendix EC80 Brake ECU\u0026nbsp;uses hard-coded credentials, which could allow an attacker to disable automatic traction control.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-798\", \"description\": \"CWE-798 Use of Hard-coded Credentials\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2026-08-27T20:45:52.804Z\"}}, \"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-71396\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-08-28T15:49:02.909444Z\"}}}], \"providerMetadata\": {\"shortName\": \"CISA-ADP\", \"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"dateUpdated\": \"2026-08-28T15:49:04.603Z\"}}]}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-71396\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-08-27T20:45:52.804Z\", \"dateReserved\": \"2026-08-10T16:03:40.501Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2026-08-27T20:45:52.804Z\", \"assignerShortName\": \"icscert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…