CVE-2026-68967 (GCVE-0-2026-68967)
Vulnerability from cvelistv5
Published
2026-08-27 20:50
Modified
2026-08-28 14:13
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
Summary
Bendix EC80 Brake ECU is vulnerable to an out-of-bounds write, which could allow an attacker
to deliver a payload that could establish an arbitrary write primitive,
which could crash the ECU.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bendix | EC80ESP+ J1708 |
Version: Z228999 |
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-68967",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-28T13:56:16.152994Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-28T14:13:53.649Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EC80ESP+ J1708",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP+ 6S/6M",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP+ PLC",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP+ 2nd CAN",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP+ Integrated TPMS",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP 6S/6M",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z266494"
},
{
"status": "unaffected",
"version": "Z302578"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP PLC",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z266494"
},
{
"status": "unaffected",
"version": "Z302578"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP 2nd CAN",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z266494"
},
{
"status": "unaffected",
"version": "Z302578"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP CAN Gateway",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z266494"
},
{
"status": "unaffected",
"version": "Z302578"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP 4S/4M",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z286098"
},
{
"status": "unaffected",
"version": "Z302579"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP PLC",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z286098"
},
{
"status": "unaffected",
"version": "Z302579"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ben Gardiner of NMFTA reported this vulnerability to CISA."
}
],
"datePublic": "2026-08-25T14:28:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Bendix EC80 Brake ECU\u0026nbsp;is vulnerable to an out-of-bounds write, which could allow an attacker \nto deliver a payload that could establish an arbitrary write primitive, \nwhich could crash the ECU."
}
],
"value": "Bendix EC80 Brake ECU\u00a0is vulnerable to an out-of-bounds write, which could allow an attacker \nto deliver a payload that could establish an arbitrary write primitive, \nwhich could crash the ECU."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-27T20:50:22.011Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-05"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-237-05.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.\u003cdiv\u003e\u003cul\u003e\u003cli\u003eEC80ESP+ J1708: Users should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ 6S/6M:\u0026nbsp;Users\n\n\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ PLC:\u0026nbsp;Users\u0026nbsp;\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ 2nd CAN:\nUsers\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ Integrated TPMS:\u0026nbsp;Users\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP 6S/6M:\nUsers\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP 2nd CAN:\nUsers\n\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP CAN Gateway:\nUsers\n\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP 4S/4M:\nUsers\n\nshould update their firmware to version Z302579.\u003c/li\u003e\u003cli\u003eEC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302579.\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e"
}
],
"value": "Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com. * EC80ESP+ J1708: Users should update their firmware to version Z300822.\n * EC80ESP+ 6S/6M:\u00a0Users\n\n\u00a0should update their firmware to version Z300822.\n * EC80ESP+ PLC:\u00a0Users\u00a0\u00a0should update their firmware to version Z300822.\n * EC80ESP+ 2nd CAN:\nUsers\u00a0should update their firmware to version Z300822.\n * EC80ESP+ Integrated TPMS:\u00a0Users\u00a0should update their firmware to version Z300822.\n * EC80ESP 6S/6M:\nUsers\nshould update their firmware to version Z302578.\n * EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302578.\n * EC80ESP 2nd CAN:\nUsers\n\nshould update their firmware to version Z302578.\n * EC80ESP CAN Gateway:\nUsers\n\nshould update their firmware to version Z302578.\n * EC80ESP 4S/4M:\nUsers\n\nshould update their firmware to version Z302579.\n * EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302579."
}
],
"source": {
"advisory": "ICSA-26-237-05",
"discovery": "EXTERNAL"
},
"title": "Out-of-bounds Write in Bendix EC80 Brake ECU",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-68967",
"datePublished": "2026-08-27T20:50:22.011Z",
"dateReserved": "2026-08-10T16:03:40.497Z",
"dateUpdated": "2026-08-28T14:13:53.649Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-68967\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-08-28T13:56:16.152994Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-08-28T14:06:14.631Z\"}}], \"cna\": {\"title\": \"Out-of-bounds Write in Bendix EC80 Brake ECU\", \"source\": {\"advisory\": \"ICSA-26-237-05\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Ben Gardiner of NMFTA reported this vulnerability to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.5, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 7.1, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ J1708\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ 6S/6M\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ PLC\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ 2nd CAN\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ Integrated TPMS\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP 6S/6M\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z266494\"}, {\"status\": \"unaffected\", \"version\": \"Z302578\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP PLC\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z266494\"}, {\"status\": \"unaffected\", \"version\": \"Z302578\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP 2nd CAN\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z266494\"}, {\"status\": \"unaffected\", \"version\": \"Z302578\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP CAN Gateway\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z266494\"}, {\"status\": \"unaffected\", \"version\": \"Z302578\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP 4S/4M\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z286098\"}, {\"status\": \"unaffected\", \"version\": \"Z302579\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP PLC\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z286098\"}, {\"status\": \"unaffected\", \"version\": \"Z302579\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com. * EC80ESP+ J1708: Users should update their firmware to version Z300822.\\n * EC80ESP+ 6S/6M:\\u00a0Users\\n\\n\\u00a0should update their firmware to version Z300822.\\n * EC80ESP+ PLC:\\u00a0Users\\u00a0\\u00a0should update their firmware to version Z300822.\\n * EC80ESP+ 2nd CAN:\\nUsers\\u00a0should update their firmware to version Z300822.\\n * EC80ESP+ Integrated TPMS:\\u00a0Users\\u00a0should update their firmware to version Z300822.\\n * EC80ESP 6S/6M:\\nUsers\\nshould update their firmware to version Z302578.\\n * EC80ESP PLC:\\nUsers\\n\\nshould update their firmware to version Z302578.\\n * EC80ESP 2nd CAN:\\nUsers\\n\\nshould update their firmware to version Z302578.\\n * EC80ESP CAN Gateway:\\nUsers\\n\\nshould update their firmware to version Z302578.\\n * EC80ESP 4S/4M:\\nUsers\\n\\nshould update their firmware to version Z302579.\\n * EC80ESP PLC:\\nUsers\\n\\nshould update their firmware to version Z302579.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.\u003cdiv\u003e\u003cul\u003e\u003cli\u003eEC80ESP+ J1708: Users should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ 6S/6M:\u0026nbsp;Users\\n\\n\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ PLC:\u0026nbsp;Users\u0026nbsp;\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ 2nd CAN:\\nUsers\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ Integrated TPMS:\u0026nbsp;Users\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP 6S/6M:\\nUsers\\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP PLC:\\nUsers\\n\\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP 2nd CAN:\\nUsers\\n\\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP CAN Gateway:\\nUsers\\n\\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP 4S/4M:\\nUsers\\n\\nshould update their firmware to version Z302579.\u003c/li\u003e\u003cli\u003eEC80ESP PLC:\\nUsers\\n\\nshould update their firmware to version Z302579.\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\", \"base64\": false}]}], \"datePublic\": \"2026-08-25T14:28:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-05\"}, {\"url\": \"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-237-05.json\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.4\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Bendix EC80 Brake ECU\\u00a0is vulnerable to an out-of-bounds write, which could allow an attacker \\nto deliver a payload that could establish an arbitrary write primitive, \\nwhich could crash the ECU.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Bendix EC80 Brake ECU\u0026nbsp;is vulnerable to an out-of-bounds write, which could allow an attacker \\nto deliver a payload that could establish an arbitrary write primitive, \\nwhich could crash the ECU.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-787\", \"description\": \"CWE-787\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2026-08-27T20:50:22.011Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-68967\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-08-28T14:13:53.649Z\", \"dateReserved\": \"2026-08-10T16:03:40.497Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2026-08-27T20:50:22.011Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…