CVE-2026-67560 (GCVE-0-2026-67560)
Vulnerability from cvelistv5
Published
2026-08-27 20:54
Modified
2026-08-28 14:13
Severity ?
7.5 (High) - CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
7.7 (High) - CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.7 (High) - CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
Summary
Bendix EC80 Brake ECU
is vulnerable to a stack-based buffer overflow, which may allow an
attacker to crash the ECU. A crafted payload can then be used to
remotely execute arbitrary code or inject arbitrary CAN bus traffic.
This could cause the loss of the ABS function, steering assist,
speedometer, and shifting.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bendix | EC80ESP+ J1708 |
Version: Z228999 |
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-67560",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-28T13:50:27.752340Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-28T14:13:53.473Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EC80ESP+ J1708",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP+ 6S/6M",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP+ PLC",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP+ 2nd CAN",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP+ Integrated TPMS",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z228999"
},
{
"status": "unaffected",
"version": "Z300822"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP 6S/6M",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z266494"
},
{
"status": "unaffected",
"version": "Z302578"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP PLC",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z266494"
},
{
"status": "unaffected",
"version": "Z302578"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP 2nd CAN",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z266494"
},
{
"status": "unaffected",
"version": "Z302578"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP CAN Gateway",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z266494"
},
{
"status": "unaffected",
"version": "Z302578"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP 4S/4M",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z286098"
},
{
"status": "unaffected",
"version": "Z302579"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EC80ESP PLC",
"vendor": "Bendix",
"versions": [
{
"status": "affected",
"version": "Z286098"
},
{
"status": "unaffected",
"version": "Z302579"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ben Gardiner of NMFTA reported this vulnerability to CISA."
}
],
"datePublic": "2026-08-25T14:28:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Bendix EC80 Brake ECU\n is vulnerable to a stack-based buffer overflow, which may allow an \nattacker to crash the ECU. A crafted payload can then be used to \nremotely execute arbitrary code or inject arbitrary CAN bus traffic. \nThis could cause the loss of the ABS function, steering assist, \nspeedometer, and shifting."
}
],
"value": "Bendix EC80 Brake ECU\n is vulnerable to a stack-based buffer overflow, which may allow an \nattacker to crash the ECU. A crafted payload can then be used to \nremotely execute arbitrary code or inject arbitrary CAN bus traffic. \nThis could cause the loss of the ABS function, steering assist, \nspeedometer, and shifting."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-27T20:54:20.022Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-05"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-237-05.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.\u003cdiv\u003e\u003cul\u003e\u003cli\u003eEC80ESP+ J1708: Users should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ 6S/6M:\u0026nbsp;Users\n\n\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ PLC:\u0026nbsp;Users\u0026nbsp;\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ 2nd CAN:\nUsers\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ Integrated TPMS:\u0026nbsp;Users\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP 6S/6M:\nUsers\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP 2nd CAN:\nUsers\n\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP CAN Gateway:\nUsers\n\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP 4S/4M:\nUsers\n\nshould update their firmware to version Z302579.\u003c/li\u003e\u003cli\u003eEC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302579.\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e"
}
],
"value": "Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com. * EC80ESP+ J1708: Users should update their firmware to version Z300822.\n * EC80ESP+ 6S/6M:\u00a0Users\n\n\u00a0should update their firmware to version Z300822.\n * EC80ESP+ PLC:\u00a0Users\u00a0\u00a0should update their firmware to version Z300822.\n * EC80ESP+ 2nd CAN:\nUsers\u00a0should update their firmware to version Z300822.\n * EC80ESP+ Integrated TPMS:\u00a0Users\u00a0should update their firmware to version Z300822.\n * EC80ESP 6S/6M:\nUsers\nshould update their firmware to version Z302578.\n * EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302578.\n * EC80ESP 2nd CAN:\nUsers\n\nshould update their firmware to version Z302578.\n * EC80ESP CAN Gateway:\nUsers\n\nshould update their firmware to version Z302578.\n * EC80ESP 4S/4M:\nUsers\n\nshould update their firmware to version Z302579.\n * EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302579."
}
],
"source": {
"advisory": "ICSA-26-237-05",
"discovery": "EXTERNAL"
},
"title": "Stack-based Buffer Overflow in Bendix EC80 Brake ECU",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-67560",
"datePublished": "2026-08-27T20:54:20.022Z",
"dateReserved": "2026-08-10T16:03:40.493Z",
"dateUpdated": "2026-08-28T14:13:53.473Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-67560\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-08-28T13:50:27.752340Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-08-28T14:06:07.043Z\"}}], \"cna\": {\"title\": \"Stack-based Buffer Overflow in Bendix EC80 Brake ECU\", \"source\": {\"advisory\": \"ICSA-26-237-05\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Ben Gardiner of NMFTA reported this vulnerability to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 7.7, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ J1708\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ 6S/6M\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ PLC\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ 2nd CAN\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP+ Integrated TPMS\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z228999\"}, {\"status\": \"unaffected\", \"version\": \"Z300822\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP 6S/6M\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z266494\"}, {\"status\": \"unaffected\", \"version\": \"Z302578\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP PLC\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z266494\"}, {\"status\": \"unaffected\", \"version\": \"Z302578\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP 2nd CAN\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z266494\"}, {\"status\": \"unaffected\", \"version\": \"Z302578\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP CAN Gateway\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z266494\"}, {\"status\": \"unaffected\", \"version\": \"Z302578\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP 4S/4M\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z286098\"}, {\"status\": \"unaffected\", \"version\": \"Z302579\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Bendix\", \"product\": \"EC80ESP PLC\", \"versions\": [{\"status\": \"affected\", \"version\": \"Z286098\"}, {\"status\": \"unaffected\", \"version\": \"Z302579\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com. * EC80ESP+ J1708: Users should update their firmware to version Z300822.\\n * EC80ESP+ 6S/6M:\\u00a0Users\\n\\n\\u00a0should update their firmware to version Z300822.\\n * EC80ESP+ PLC:\\u00a0Users\\u00a0\\u00a0should update their firmware to version Z300822.\\n * EC80ESP+ 2nd CAN:\\nUsers\\u00a0should update their firmware to version Z300822.\\n * EC80ESP+ Integrated TPMS:\\u00a0Users\\u00a0should update their firmware to version Z300822.\\n * EC80ESP 6S/6M:\\nUsers\\nshould update their firmware to version Z302578.\\n * EC80ESP PLC:\\nUsers\\n\\nshould update their firmware to version Z302578.\\n * EC80ESP 2nd CAN:\\nUsers\\n\\nshould update their firmware to version Z302578.\\n * EC80ESP CAN Gateway:\\nUsers\\n\\nshould update their firmware to version Z302578.\\n * EC80ESP 4S/4M:\\nUsers\\n\\nshould update their firmware to version Z302579.\\n * EC80ESP PLC:\\nUsers\\n\\nshould update their firmware to version Z302579.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.\u003cdiv\u003e\u003cul\u003e\u003cli\u003eEC80ESP+ J1708: Users should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ 6S/6M:\u0026nbsp;Users\\n\\n\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ PLC:\u0026nbsp;Users\u0026nbsp;\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ 2nd CAN:\\nUsers\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP+ Integrated TPMS:\u0026nbsp;Users\u0026nbsp;should update their firmware to version Z300822.\u003c/li\u003e\u003cli\u003eEC80ESP 6S/6M:\\nUsers\\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP PLC:\\nUsers\\n\\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP 2nd CAN:\\nUsers\\n\\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP CAN Gateway:\\nUsers\\n\\nshould update their firmware to version Z302578.\u003c/li\u003e\u003cli\u003eEC80ESP 4S/4M:\\nUsers\\n\\nshould update their firmware to version Z302579.\u003c/li\u003e\u003cli\u003eEC80ESP PLC:\\nUsers\\n\\nshould update their firmware to version Z302579.\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\", \"base64\": false}]}], \"datePublic\": \"2026-08-25T14:28:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-05\"}, {\"url\": \"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-237-05.json\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.4\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Bendix EC80 Brake ECU\\n is vulnerable to a stack-based buffer overflow, which may allow an \\nattacker to crash the ECU. A crafted payload can then be used to \\nremotely execute arbitrary code or inject arbitrary CAN bus traffic. \\nThis could cause the loss of the ABS function, steering assist, \\nspeedometer, and shifting.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Bendix EC80 Brake ECU\\n is vulnerable to a stack-based buffer overflow, which may allow an \\nattacker to crash the ECU. A crafted payload can then be used to \\nremotely execute arbitrary code or inject arbitrary CAN bus traffic. \\nThis could cause the loss of the ABS function, steering assist, \\nspeedometer, and shifting.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2026-08-27T20:54:20.022Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-67560\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-08-28T14:13:53.473Z\", \"dateReserved\": \"2026-08-10T16:03:40.493Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2026-08-27T20:54:20.022Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…