CVE-2026-59241 (GCVE-0-2026-59241)
Vulnerability from cvelistv5
Published
2026-10-13 09:18
Modified
2026-10-16 17:18
CWE
  • CWE-266 - Incorrect Privilege Assignment
Summary
A vulnerability has been identified in SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions < V8.0 Update 11), SIMATIC WinCC V8.1 (All versions < V8.1 Update 7). The affected application does not sufficiently restrict the permissions assigned to a database role. This could allow an authenticated remote attacker with database access to escalate privileges and execute arbitrary commands on the host system where SIMATIC WinCC is installed, potentially leading to a compromise of the system.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-59241",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-16T16:59:59.244233Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-16T17:18:25.910Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0 Update 11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1 Update 7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 11), SIMATIC WinCC V8.1 (All versions \u003c V8.1 Update 7). The affected application does not sufficiently restrict the permissions assigned to a database role.\r\nThis could allow an authenticated remote attacker with database access to escalate privileges and execute arbitrary commands on the host system where SIMATIC WinCC is installed, potentially leading to a compromise of the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-266",
              "description": "CWE-266: Incorrect Privilege Assignment",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:18:29.536Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-550198.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-59241",
    "datePublished": "2026-10-13T09:18:29.536Z",
    "dateReserved": "2026-07-03T14:16:52.881Z",
    "dateUpdated": "2026-10-16T17:18:25.910Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-59241\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-10-16T16:59:59.244233Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-10-16T17:00:00.367Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SIMATIC WinCC V7.5\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC WinCC V8.0\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.0 Update 11\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC WinCC V8.1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.1 Update 7\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-550198.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 11), SIMATIC WinCC V8.1 (All versions \u003c V8.1 Update 7). The affected application does not sufficiently restrict the permissions assigned to a database role.\\r\\nThis could allow an authenticated remote attacker with database access to escalate privileges and execute arbitrary commands on the host system where SIMATIC WinCC is installed, potentially leading to a compromise of the system.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-266\", \"description\": \"CWE-266: Incorrect Privilege Assignment\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2026-10-13T09:18:29.536Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-59241\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-10-16T17:18:25.910Z\", \"dateReserved\": \"2026-07-03T14:16:52.881Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2026-10-13T09:18:29.536Z\", \"assignerShortName\": \"siemens\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…