CVE-2026-50609 (GCVE-0-2026-50609)
Vulnerability from cvelistv5
Published
2026-09-17 08:21
Modified
2026-09-17 12:24
CWE
  • CWE-284 - Improper Access Control
Summary
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.
Impacted products
Vendor Product Version
Acer System Monitoring Version: *   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-50609",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-17T12:23:07.250428Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-17T12:24:11.273Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "System Monitoring",
          "vendor": "Acer",
          "versions": [
            {
              "lessThanOrEqual": "1.0.19.2",
              "status": "affected",
              "version": "*",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Cassius GARAT"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
            }
          ],
          "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-180",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
            }
          ]
        },
        {
          "capecId": "CAPEC-233",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-233 Privilege Escalation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "exploitMaturity": "UNREPORTED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-17T08:21:29.786Z",
        "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "shortName": "Acer"
      },
      "references": [
        {
          "url": "https://community.acer.com/en/kb/articles/19876"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
    "assignerShortName": "Acer",
    "cveId": "CVE-2026-50609",
    "datePublished": "2026-09-17T08:21:29.786Z",
    "dateReserved": "2026-06-05T07:22:32.054Z",
    "dateUpdated": "2026-09-17T12:24:11.273Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-50609\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-09-17T12:23:07.250428Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-09-17T12:23:58.785Z\"}}], \"cna\": {\"title\": \"Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"Cassius GARAT\"}], \"impacts\": [{\"capecId\": \"CAPEC-180\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels\"}]}, {\"capecId\": \"CAPEC-233\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-233 Privilege Escalation\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 7.4, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U\", \"exploitMaturity\": \"UNREPORTED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"HIGH\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Acer\", \"product\": \"System Monitoring\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.0.19.2\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Update to one of the following versions or later:\\n\\n  *  NitroSense v5.2.84\\n  *  PredatorSense v5.2.109\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://community.acer.com/en/kb/articles/19876\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.5\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284: Improper Access Control\"}]}], \"providerMetadata\": {\"orgId\": \"8fc372e3-d9c5-46e4-9410-38469745c639\", \"shortName\": \"Acer\", \"dateUpdated\": \"2026-09-17T08:21:29.786Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-50609\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-09-17T12:24:11.273Z\", \"dateReserved\": \"2026-06-05T07:22:32.054Z\", \"assignerOrgId\": \"8fc372e3-d9c5-46e4-9410-38469745c639\", \"datePublished\": \"2026-09-17T08:21:29.786Z\", \"assignerShortName\": \"Acer\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…