Summary
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2025 |
Version: 0 < V225.0 Update 15 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50062",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-12T20:52:45.648082Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-12T20:55:41.329Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 15",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2026",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V226.0 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2025 (All versions \u003c V225.0 Update 15), Solid Edge SE2026 (All versions \u003c V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:20:18.621Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-621657.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-50062",
"datePublished": "2026-08-11T12:20:18.621Z",
"dateReserved": "2026-06-03T11:07:02.668Z",
"dateUpdated": "2026-08-12T20:55:41.329Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-50062\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-08-12T20:52:45.648082Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-08-12T20:52:50.579Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"Solid Edge SE2025\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V225.0 Update 15\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Solid Edge SE2026\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V226.0 Update 7\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-621657.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Solid Edge SE2025 (All versions \u003c V225.0 Update 15), Solid Edge SE2026 (All versions \u003c V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-125\", \"description\": \"CWE-125: Out-of-bounds Read\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2026-08-11T12:20:18.621Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-50062\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-08-12T20:55:41.329Z\", \"dateReserved\": \"2026-06-03T11:07:02.668Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2026-08-11T12:20:18.621Z\", \"assignerShortName\": \"siemens\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…