CVE-2026-44572 (GCVE-0-2026-44572)
Vulnerability from cvelistv5
Published
2026-05-13 15:57
Modified
2026-05-14 15:33
CWE
  • CWE-349 - Acceptance of Extraneous Untrusted Data With Trusted Data
Summary
Next.js is a React framework for building full-stack web applications. From 12.2.0 to before 15.5.16 and 16.2.5, an external client could send a x-nextjs-data header on a normal request to a path handled by middleware that returns a redirect. When that happened, the middleware/proxy could treat the request as a data request and replace the standard Location redirect header with the internal x-nextjs-redirect header. Browsers do not follow x-nextjs-redirect, so the response became an unusable redirect for normal clients. If the application was deployed behind a CDN or reverse proxy that caches 3xx responses without varying on this header, a single attacker request could poison the cached redirect response for the affected path. Subsequent visitors could then receive a cached redirect response without a Location header, causing a denial of service for that redirect path until the cache entry expired or was purged. This vulnerability is fixed in 15.5.16 and 16.2.5.
Impacted products
Vendor Product Version
vercel next.js Version: >= 12.2.0, < 15.5.16
Version: >= 16.0.0, < 16.2.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-44572",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-14T15:32:48.568772Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-14T15:33:10.541Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "next.js",
          "vendor": "vercel",
          "versions": [
            {
              "status": "affected",
              "version": "\u003e= 12.2.0, \u003c 15.5.16"
            },
            {
              "status": "affected",
              "version": "\u003e= 16.0.0, \u003c 16.2.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Next.js is a React framework for building full-stack web applications. From 12.2.0 to before 15.5.16 and 16.2.5, an external client could send a x-nextjs-data header on a normal request to a path handled by middleware that returns a redirect. When that happened, the middleware/proxy could treat the request as a data request and replace the standard Location redirect header with the internal x-nextjs-redirect header. Browsers do not follow x-nextjs-redirect, so the response became an unusable redirect for normal clients. If the application was deployed behind a CDN or reverse proxy that caches 3xx responses without varying on this header, a single attacker request could poison the cached redirect response for the affected path. Subsequent visitors could then receive a cached redirect response without a Location header, causing a denial of service for that redirect path until the cache entry expired or was purged. This vulnerability is fixed in 15.5.16 and 16.2.5."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-349",
              "description": "CWE-349: Acceptance of Extraneous Untrusted Data With Trusted Data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-13T15:57:15.750Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/vercel/next.js/security/advisories/GHSA-3g8h-86w9-wvmq",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/vercel/next.js/security/advisories/GHSA-3g8h-86w9-wvmq"
        }
      ],
      "source": {
        "advisory": "GHSA-3g8h-86w9-wvmq",
        "discovery": "UNKNOWN"
      },
      "title": "Next.js: Middleware / Proxy redirects can be cache-poisoned"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2026-44572",
    "datePublished": "2026-05-13T15:57:15.750Z",
    "dateReserved": "2026-05-06T21:49:12.424Z",
    "dateUpdated": "2026-05-14T15:33:10.541Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…