CVE-2026-44276 (GCVE-0-2026-44276)
Vulnerability from cvelistv5
Published
2026-07-22 15:13
Modified
2026-07-22 15:55
CWE
  • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the REST API. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-44276",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-22T15:54:59.985096Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-22T15:55:09.983Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "20.2.0.0 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "other",
          "value": "Dell would like to thank shauntp for reporting this issue."
        }
      ],
      "datePublic": "2026-07-14T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the REST API. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure."
            }
          ],
          "value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the REST API. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-22T15:13:07.215Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.4"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2026-44276",
    "datePublished": "2026-07-22T15:13:07.215Z",
    "dateReserved": "2026-05-05T17:04:45.714Z",
    "dateUpdated": "2026-07-22T15:55:09.983Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-44276\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-07-22T15:54:59.985096Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-07-22T15:55:06.704Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"other\", \"value\": \"Dell would like to thank shauntp for reporting this issue.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 6, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"PowerProtect Data Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"20.2.0.0 or later\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2026-07-14T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.4\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the REST API. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the REST API. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-200\", \"description\": \"CWE-200: Exposure of Sensitive Information to an Unauthorized Actor\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2026-07-22T15:13:07.215Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-44276\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-07-22T15:55:09.983Z\", \"dateReserved\": \"2026-05-05T17:04:45.714Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2026-07-22T15:13:07.215Z\", \"assignerShortName\": \"dell\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…