CVE-2026-39460 (GCVE-0-2026-39460)
Vulnerability from cvelistv5
Published
2026-10-09 14:30
Modified
2026-10-12 22:54
Severity ?
8.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
9.3 (Critical) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N
9.3 (Critical) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N
VLAI Severity ?
EPSS score ?
CWE
Summary
Usernames and passwords, including the default factory credentials, are stored in plaintext within the configuration file. With administrator rights, the configuration file can be viewed through the CLI or they can be exported from the device through a TFTP transfer from the web interface. A TFTP transfer can be initiated through SNMP which does not require authentication.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Red Lion Controls | 700 Series |
Version: 0 < Firmware Versions 3.11.0 Version: 0 < Bootloader Versions 2.0.6.1 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-39460",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-12T22:49:00.342565Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T22:54:01.598Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "700 Series",
"vendor": "Red Lion Controls",
"versions": [
{
"lessThan": "Firmware Versions 3.11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "Bootloader Versions 2.0.6.1",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "3.11.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gabrianna (Ria) Milloway of Idaho National Laboratory reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Usernames and passwords, including the default factory credentials, are stored in plaintext within the configuration file. With administrator rights, the configuration file can be viewed through the CLI or they can be exported from the device through a TFTP transfer from the web interface. A TFTP transfer can be initiated through SNMP which does not require authentication."
}
],
"value": "Usernames and passwords, including the default factory credentials, are stored in plaintext within the configuration file. With administrator rights, the configuration file can be viewed through the CLI or they can be exported from the device through a TFTP transfer from the web interface. A TFTP transfer can be initiated through SNMP which does not require authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-09T14:30:47.942Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.hms-networks.com/"
},
{
"url": "https://www.hms-networks.com/cybersecurity"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-281-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-281-01.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eRed Lion controls recommends the following upgrades for the N-Tron 700 Series: \u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpgrade to firmware version 3.11.1 or greater\u003c/li\u003e\u003cli\u003eConfigure or disable the SNMP communities\u003c/li\u003e\u003cli\u003eDisable access to the web GUI\u003c/li\u003e\u003c/ul\u003e\n\u003cp\u003eThe upgrade procedure document can be viewed \u003ca href=\"https://www.hms-networks.com/\"\u003ehere\u003c/a\u003e.\u003c/p\u003e\n\u003cp\u003eThe advisory issued by HMS Networks regarding these vulnerabilities can be viewed \u003ca href=\"https://www.hms-networks.com/cybersecurity\"\u003ehere\u003c/a\u003e.\u003c/p\u003e"
}
],
"value": "Red Lion controls recommends the following upgrades for the N-Tron 700 Series: \n\n\n * Upgrade to firmware version 3.11.1 or greater\n * Configure or disable the SNMP communities\n * Disable access to the web GUI\n\n\n\n\n\nThe upgrade procedure document can be viewed here https://www.hms-networks.com/ .\n\n\n\n\nThe advisory issued by HMS Networks regarding these vulnerabilities can be viewed here https://www.hms-networks.com/cybersecurity ."
}
],
"source": {
"advisory": "ICSA-26-281-01",
"discovery": "EXTERNAL"
},
"title": "Red Lion Controls N-Tron 700 Series Insufficiently Protected Credentials",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-39460",
"datePublished": "2026-10-09T14:30:47.942Z",
"dateReserved": "2026-04-08T19:28:49.400Z",
"dateUpdated": "2026-10-12T22:54:01.598Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-39460\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-10-12T22:49:00.342565Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-10-12T22:52:52.395Z\"}}], \"cna\": {\"title\": \"Red Lion Controls N-Tron 700 Series Insufficiently Protected Credentials\", \"source\": {\"advisory\": \"ICSA-26-281-01\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Gabrianna (Ria) Milloway of Idaho National Laboratory reported this vulnerability to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 9.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"HIGH\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Red Lion Controls\", \"product\": \"700 Series\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"Firmware Versions 3.11.0\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"Bootloader Versions 2.0.6.1\", \"versionType\": \"custom\"}, {\"status\": \"unaffected\", \"version\": \"3.11.1\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Red Lion controls recommends the following upgrades for the N-Tron 700 Series: \\n\\n\\n * Upgrade to firmware version 3.11.1 or greater\\n * Configure or disable the SNMP communities\\n * Disable access to the web GUI\\n\\n\\n\\n\\n\\nThe upgrade procedure document can be viewed here https://www.hms-networks.com/ .\\n\\n\\n\\n\\nThe advisory issued by HMS Networks regarding these vulnerabilities can be viewed here https://www.hms-networks.com/cybersecurity .\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eRed Lion controls recommends the following upgrades for the N-Tron 700 Series: \u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpgrade to firmware version 3.11.1 or greater\u003c/li\u003e\u003cli\u003eConfigure or disable the SNMP communities\u003c/li\u003e\u003cli\u003eDisable access to the web GUI\u003c/li\u003e\u003c/ul\u003e\\n\u003cp\u003eThe upgrade procedure document can be viewed \u003ca href=\\\"https://www.hms-networks.com/\\\"\u003ehere\u003c/a\u003e.\u003c/p\u003e\\n\u003cp\u003eThe advisory issued by HMS Networks regarding these vulnerabilities can be viewed \u003ca href=\\\"https://www.hms-networks.com/cybersecurity\\\"\u003ehere\u003c/a\u003e.\u003c/p\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://www.hms-networks.com/\"}, {\"url\": \"https://www.hms-networks.com/cybersecurity\"}, {\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-26-281-01\"}, {\"url\": \"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-281-01.json\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.5\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Usernames and passwords, including the default factory credentials, are stored in plaintext within the configuration file. With administrator rights, the configuration file can be viewed through the CLI or they can be exported from the device through a TFTP transfer from the web interface. A TFTP transfer can be initiated through SNMP which does not require authentication.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Usernames and passwords, including the default factory credentials, are stored in plaintext within the configuration file. With administrator rights, the configuration file can be viewed through the CLI or they can be exported from the device through a TFTP transfer from the web interface. A TFTP transfer can be initiated through SNMP which does not require authentication.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-522\", \"description\": \"CWE-522\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2026-10-09T14:30:47.942Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-39460\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-10-12T22:54:01.598Z\", \"dateReserved\": \"2026-04-08T19:28:49.400Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2026-10-09T14:30:47.942Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.