CVE-2026-35504 (GCVE-0-2026-35504)
Vulnerability from cvelistv5
Published
2026-05-12 20:19
Modified
2026-05-12 21:12
CWE
  • CWE-93 - Improper neutralization of CRLF sequences ('CRLF injection')
Summary
PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-35504",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-12T21:01:40.300358Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-12T21:12:55.834Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerSYSTEM Center 2020",
          "vendor": "Subnet Solutions",
          "versions": [
            {
              "lessThanOrEqual": "5.28.x",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PowerSYSTEM Center 2024",
          "vendor": "Subnet Solutions",
          "versions": [
            {
              "lessThanOrEqual": "6.1.x",
              "status": "affected",
              "version": "6.0.x",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PowerSYSTEM Center 2026",
          "vendor": "Subnet Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "7.0.x"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Kelly Stich of Subnet Solutions Inc. reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-05-13T05:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication."
            }
          ],
          "value": "PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-93",
              "description": "CWE-93 Improper neutralization of CRLF sequences (\u0027CRLF injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-12T20:45:23.739Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-132-02"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-132-02.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\u003cbr\u003e\n\u003cbr\u003eFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\u003cbr\u003e\n\u003cbr\u003eSubnet Solutions recommends users do the following in order to reduce risk:\n\u003cbr\u003e* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\u003cbr\u003e* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\u003cbr\u003e* Configure a notification rule that triggers in any bulk account export activity."
            }
          ],
          "value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\n\n\nFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\n\n\nSubnet Solutions recommends users do the following in order to reduce risk:\n\n* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\n* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\n* Configure a notification rule that triggers in any bulk account export activity."
        }
      ],
      "source": {
        "advisory": "ICSA-26-132-02",
        "discovery": "INTERNAL"
      },
      "title": "Subnet Solutions PowerSYSTEM Center CRLF injection",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-35504",
    "datePublished": "2026-05-12T20:19:38.126Z",
    "dateReserved": "2026-04-16T14:05:42.158Z",
    "dateUpdated": "2026-05-12T21:12:55.834Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-35504\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-05-12T21:01:40.300358Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-05-12T21:12:45.666Z\"}}], \"cna\": {\"title\": \"Subnet Solutions PowerSYSTEM Center CRLF injection\", \"source\": {\"advisory\": \"ICSA-26-132-02\", \"discovery\": \"INTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Kelly Stich of Subnet Solutions Inc. reported these vulnerabilities to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 5.1, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"LOW\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"LOW\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"LOW\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.5, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Subnet Solutions\", \"product\": \"PowerSYSTEM Center 2020\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"5.28.x\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Subnet Solutions\", \"product\": \"PowerSYSTEM Center 2024\", \"versions\": [{\"status\": \"affected\", \"version\": \"6.0.x\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"6.1.x\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Subnet Solutions\", \"product\": \"PowerSYSTEM Center 2026\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.0.x\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\\n\\n\\n\\nFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\\n\\n\\n\\nSubnet Solutions recommends users do the following in order to reduce risk:\\n\\n* Monitor user activity records to ensure users are following acceptable usage policies of the application.\\n\\n* Restrict access to Notification Settings to trusted Administrators Monitor \\\"Send from Address\\\" in settings and Activity Records.\\n\\n* Configure a notification rule that triggers in any bulk account export activity.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\\n\u003cbr\u003e\\n\u003cbr\u003eFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\\n\u003cbr\u003e\\n\u003cbr\u003eSubnet Solutions recommends users do the following in order to reduce risk:\\n\u003cbr\u003e* Monitor user activity records to ensure users are following acceptable usage policies of the application.\\n\u003cbr\u003e* Restrict access to Notification Settings to trusted Administrators Monitor \\\"Send from Address\\\" in settings and Activity Records.\\n\u003cbr\u003e* Configure a notification rule that triggers in any bulk account export activity.\", \"base64\": false}]}], \"datePublic\": \"2026-05-13T05:00:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-26-132-02\"}, {\"url\": \"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-132-02.json\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.2\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-93\", \"description\": \"CWE-93 Improper neutralization of CRLF sequences (\u0027CRLF injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2026-05-12T20:45:23.739Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-35504\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-05-12T21:12:55.834Z\", \"dateReserved\": \"2026-04-16T14:05:42.158Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2026-05-12T20:19:38.126Z\", \"assignerShortName\": \"icscert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…