CVE-2026-35226 (GCVE-0-2026-35226)
Vulnerability from cvelistv5
Published
2026-07-29 07:05
Modified
2026-07-29 14:27
Severity ?
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-787 - Out-of-bounds Write
Summary
An out‑of‑bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime system and results in a controlled stop of the PLC application.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS PROFINET |
Version: 4.4.0.0 ≤ |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-35226",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-29T14:27:26.242820Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-29T14:27:45.179Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS PROFINET",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "4.4.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_profinet:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.8.0.0",
"versionStartIncluding": "4.4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "ABB"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn out\u2011of\u2011bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime system and results in a controlled stop of the PLC application.\u003c/p\u003e"
}
],
"value": "An out\u2011of\u2011bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime system and results in a controlled stop of the PLC application."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-29T07:05:57.508Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-041/"
}
],
"source": {
"advisory": "VDE-2026-041",
"defect": [
"CERT@VDE#642012"
],
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Write in CODESYS PROFINET Controller",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-35226",
"datePublished": "2026-07-29T07:05:57.508Z",
"dateReserved": "2026-04-01T19:54:21.499Z",
"dateUpdated": "2026-07-29T14:27:45.179Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-35226\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-07-29T14:27:26.242820Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-07-29T14:27:30.792Z\"}}], \"cna\": {\"title\": \"Out-of-bounds Write in CODESYS PROFINET Controller\", \"source\": {\"defect\": [\"CERT@VDE#642012\"], \"advisory\": \"VDE-2026-041\", \"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"ABB\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 7.1, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.5, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"CODESYS\", \"product\": \"CODESYS PROFINET\", \"versions\": [{\"status\": \"affected\", \"version\": \"4.4.0.0\", \"lessThan\": \"4.8.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.certvde.com/en/advisories/VDE-2026-041/\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.4.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An out\\u2011of\\u2011bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime system and results in a controlled stop of the PLC application.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eAn out\\u2011of\\u2011bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime system and results in a controlled stop of the PLC application.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-787\", \"description\": \"CWE-787 Out-of-bounds Write\"}]}], \"cpeApplicability\": [{\"nodes\": [{\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:codesys:codesys_profinet:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"4.8.0.0\", \"versionStartIncluding\": \"4.4.0.0\"}], \"operator\": \"OR\"}], \"operator\": \"OR\"}], \"providerMetadata\": {\"orgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"shortName\": \"CERTVDE\", \"dateUpdated\": \"2026-07-29T07:05:57.508Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-35226\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-07-29T14:27:45.179Z\", \"dateReserved\": \"2026-04-01T19:54:21.499Z\", \"assignerOrgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"datePublished\": \"2026-07-29T07:05:57.508Z\", \"assignerShortName\": \"CERTVDE\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…