CVE-2026-2139 (GCVE-0-2026-2139)
Vulnerability from cvelistv5
Published
2026-02-08 06:32
Modified
2026-02-23 09:39
CWE
Summary
A vulnerability was determined in Tenda TX9 up to 22.03.02.10_multi. Affected by this vulnerability is the function sub_432580 of the file /goform/fast_setting_wifi_set. This manipulation of the argument ssid causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
Impacted products
Vendor Product Version
Tenda TX9 Version: 22.03.02.10_multi
    cpe:2.3:o:tenda:tx9_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2139",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-10T19:55:32.054109Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-10T19:55:57.658Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:tx9_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "TX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10_multi"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "kdb3169 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda TX9 up to 22.03.02.10_multi. Affected by this vulnerability is the function sub_432580 of the file /goform/fast_setting_wifi_set. This manipulation of the argument ssid causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-23T09:39:05.487Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-344774 | Tenda TX9 fast_setting_wifi_set sub_432580 buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.344774"
        },
        {
          "name": "VDB-344774 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.344774"
        },
        {
          "name": "Submit #747250 | Tenda TX9 V22.03.02.10_multi Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.747250"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/MRAdera/IoT-Vuls/blob/main/tenda/tx9%20pro/fast_setting_wifi_set.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/MRAdera/IoT-Vuls/blob/main/tenda/tx9%20pro/fast_setting_wifi_set.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-02-06T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-02-06T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-02-09T07:43:14.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda TX9 fast_setting_wifi_set sub_432580 buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-2139",
    "datePublished": "2026-02-08T06:32:09.469Z",
    "dateReserved": "2026-02-06T21:02:55.976Z",
    "dateUpdated": "2026-02-23T09:39:05.487Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-2139\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-02-10T19:55:32.054109Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-02-10T19:55:54.152Z\"}}], \"cna\": {\"title\": \"Tenda TX9 fast_setting_wifi_set sub_432580 buffer overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"kdb3169 (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:tenda:tx9_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"Tenda\", \"product\": \"TX9\", \"versions\": [{\"status\": \"affected\", \"version\": \"22.03.02.10_multi\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2026-02-06T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2026-02-06T01:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2026-02-09T07:43:14.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.344774\", \"name\": \"VDB-344774 | Tenda TX9 fast_setting_wifi_set sub_432580 buffer overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.344774\", \"name\": \"VDB-344774 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.747250\", \"name\": \"Submit #747250 | Tenda TX9 V22.03.02.10_multi Buffer Overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/MRAdera/IoT-Vuls/blob/main/tenda/tx9%20pro/fast_setting_wifi_set.md\", \"tags\": [\"related\"]}, {\"url\": \"https://github.com/MRAdera/IoT-Vuls/blob/main/tenda/tx9%20pro/fast_setting_wifi_set.md#poc\", \"tags\": [\"exploit\"]}, {\"url\": \"https://www.tenda.com.cn/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was determined in Tenda TX9 up to 22.03.02.10_multi. Affected by this vulnerability is the function sub_432580 of the file /goform/fast_setting_wifi_set. This manipulation of the argument ssid causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-120\", \"description\": \"Buffer Overflow\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-119\", \"description\": \"Memory Corruption\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2026-02-23T09:39:05.487Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-2139\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-02-23T09:39:05.487Z\", \"dateReserved\": \"2026-02-06T21:02:55.976Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2026-02-08T06:32:09.469Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…