CVE-2026-19893 (GCVE-0-2026-19893)
Vulnerability from cvelistv5
Published
2026-08-15 12:00
Modified
2026-08-18 13:38
CWE
  • CWE-276 - Incorrect Default Permissions
  • CWE-266 - Incorrect Privilege Assignment
Summary
A vulnerability was identified in D-Link DIR-842 2.01.B04. This impacts an unknown function of the file /etc/vsftpd.conf of the component vsftpd. Such manipulation leads to incorrect default permissions. It is possible to launch the attack remotely. A high complexity level is associated with this attack. The exploitability is said to be difficult.
Impacted products
Vendor Product Version
D-Link DIR-842 Version: 2.01.B04
    cpe:2.3:h:d-link:dir-842:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-19893",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-18T13:07:26.555752Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-18T13:38:48.190Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:d-link:dir-842:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "vsftpd"
          ],
          "product": "DIR-842",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "2.01.B04"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "L14Utopia (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in D-Link DIR-842 2.01.B04. This impacts an unknown function of the file /etc/vsftpd.conf of the component vsftpd. Such manipulation leads to incorrect default permissions. It is possible to launch the attack remotely. A high complexity level is associated with this attack. The exploitability is said to be difficult."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 2.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 3.1,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:N/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 3.1,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:N/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 2.1,
            "vectorString": "AV:N/AC:H/Au:S/C:N/I:P/A:N/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-266",
              "description": "Incorrect Privilege Assignment",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-15T12:00:08.899Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-390081 | D-Link DIR-842 vsftpd vsftpd.conf default permission",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/vuln/390081"
        },
        {
          "name": "VDB-390081 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/390081/cti"
        },
        {
          "name": "CVE-2026-19893 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-19893"
        },
        {
          "name": "Submit #870588 | D-Link DIR-842 DIR-842 2.01.B04 Misconfiguration",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/870588"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://app.notion.com/p/DIR-842-2-01-B04-38b1f5ba98908074af60fc69628dfb71?source=copy_link"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-08-14T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-08-14T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-08-14T20:50:32.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DIR-842 vsftpd vsftpd.conf default permission",
      "x_generator": [
        "VulDB PVTS v202608"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-19893",
    "datePublished": "2026-08-15T12:00:08.899Z",
    "dateReserved": "2026-08-14T18:45:04.797Z",
    "dateUpdated": "2026-08-18T13:38:48.190Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…