CVE-2026-19630 (GCVE-0-2026-19630)
Vulnerability from cvelistv5
Published
2026-10-21 12:41
Modified
2026-10-21 17:19
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-407 - Inefficient Algorithmic Complexity
Summary
In a BIND resolver, inbound DNS protocol messages with a particular structure will result in additional processing, with no limit imposed by BIND. A DNS message with a maliciously large number of such structures will cause BIND to consume disproportionate amounts of CPU time and memory during processing.
This issue affects BIND 9 versions 9.11.0 through 9.18.50, 9.20.0 through 9.20.29, 9.21.0 through 9.21.26, 9.11.3-S1 through 9.18.50-S1, and 9.20.9-S1 through 9.20.29-S1.
References
| URL | Tags | |
|---|---|---|
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-19630",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-21T15:19:21.749441Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-21T17:19:14.434Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "BIND 9",
"vendor": "ISC",
"versions": [
{
"lessThanOrEqual": "9.18.50",
"status": "affected",
"version": "9.11.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "9.20.29",
"status": "affected",
"version": "9.20.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "9.21.26",
"status": "affected",
"version": "9.21.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "9.18.50-S1",
"status": "affected",
"version": "9.11.3-S1",
"versionType": "custom"
},
{
"lessThanOrEqual": "9.20.29-S1",
"status": "affected",
"version": "9.20.9-S1",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:isc:bind:*:*:*:*:*:*:*:*",
"versionEndIncluding": "9.18.50",
"versionStartIncluding": "9.11.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:isc:bind:*:*:*:*:*:*:*:*",
"versionEndIncluding": "9.20.29",
"versionStartIncluding": "9.20.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:isc:bind:*:*:*:*:*:*:*:*",
"versionEndIncluding": "9.21.26",
"versionStartIncluding": "9.21.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:isc:bind:*:*:*:*:*:*:*:*",
"versionEndIncluding": "9.18.50-S1",
"versionStartIncluding": "9.11.3-S1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:isc:bind:*:*:*:*:*:*:*:*",
"versionEndIncluding": "9.20.29-S1",
"versionStartIncluding": "9.20.9-S1",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"datePublic": "2026-10-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "In a BIND resolver, inbound DNS protocol messages with a particular structure will result in additional processing, with no limit imposed by BIND. A DNS message with a maliciously large number of such structures will cause BIND to consume disproportionate amounts of CPU time and memory during processing.\nThis issue affects BIND 9 versions 9.11.0 through 9.18.50, 9.20.0 through 9.20.29, 9.21.0 through 9.21.26, 9.11.3-S1 through 9.18.50-S1, and 9.20.9-S1 through 9.20.29-S1."
}
],
"exploits": [
{
"lang": "en",
"value": "This flaw was discovered in internal testing. We are not aware of any active exploits."
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "Potential CPU and/or memory exhaustion leading to denial-of-service."
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-407",
"description": "CWE-407 Inefficient Algorithmic Complexity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-21T12:41:04.379Z",
"orgId": "404fd4d2-a609-4245-b543-2c944a302a22",
"shortName": "isc"
},
"references": [
{
"name": "CVE-2026-19630",
"tags": [
"vendor-advisory"
],
"url": "https://kb.isc.org/docs/cve-2026-19630"
},
{
"tags": [
"patch"
],
"url": "https://downloads.isc.org/isc/bind9/9.20.30"
},
{
"tags": [
"patch"
],
"url": "https://downloads.isc.org/isc/bind9/9.21.27"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to the patched release most closely related to your current version of BIND 9: 9.20.30, 9.21.27, or 9.20.30-S1."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Amplified resource exhaustion in inbound message processing",
"workarounds": [
{
"lang": "en",
"value": "No workarounds known."
}
],
"x_generator": {
"engine": "cvelib 1.8.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "404fd4d2-a609-4245-b543-2c944a302a22",
"assignerShortName": "isc",
"cveId": "CVE-2026-19630",
"datePublished": "2026-10-21T12:41:04.379Z",
"dateReserved": "2026-08-12T15:49:27.570Z",
"dateUpdated": "2026-10-21T17:19:14.434Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-19630\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-10-21T15:19:21.749441Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-10-21T17:10:01.170Z\"}}], \"cna\": {\"title\": \"Amplified resource exhaustion in inbound message processing\", \"source\": {\"discovery\": \"INTERNAL\"}, \"impacts\": [{\"descriptions\": [{\"lang\": \"en\", \"value\": \"Potential CPU and/or memory exhaustion leading to denial-of-service.\"}]}], \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}], \"affected\": [{\"vendor\": \"ISC\", \"product\": \"BIND 9\", \"versions\": [{\"status\": \"affected\", \"version\": \"9.11.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.18.50\"}, {\"status\": \"affected\", \"version\": \"9.20.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.20.29\"}, {\"status\": \"affected\", \"version\": \"9.21.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.21.26\"}, {\"status\": \"affected\", \"version\": \"9.11.3-S1\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.18.50-S1\"}, {\"status\": \"affected\", \"version\": \"9.20.9-S1\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.20.29-S1\"}], \"defaultStatus\": \"unaffected\"}], \"exploits\": [{\"lang\": \"en\", \"value\": \"This flaw was discovered in internal testing. We are not aware of any active exploits.\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Upgrade to the patched release most closely related to your current version of BIND 9: 9.20.30, 9.21.27, or 9.20.30-S1.\"}], \"datePublic\": \"2026-10-21T00:00:00.000Z\", \"references\": [{\"url\": \"https://kb.isc.org/docs/cve-2026-19630\", \"name\": \"CVE-2026-19630\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://downloads.isc.org/isc/bind9/9.20.30\", \"tags\": [\"patch\"]}, {\"url\": \"https://downloads.isc.org/isc/bind9/9.21.27\", \"tags\": [\"patch\"]}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"No workarounds known.\"}], \"x_generator\": {\"engine\": \"cvelib 1.8.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"In a BIND resolver, inbound DNS protocol messages with a particular structure will result in additional processing, with no limit imposed by BIND. A DNS message with a maliciously large number of such structures will cause BIND to consume disproportionate amounts of CPU time and memory during processing.\\nThis issue affects BIND 9 versions 9.11.0 through 9.18.50, 9.20.0 through 9.20.29, 9.21.0 through 9.21.26, 9.11.3-S1 through 9.18.50-S1, and 9.20.9-S1 through 9.20.29-S1.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-407\", \"description\": \"CWE-407 Inefficient Algorithmic Complexity\"}]}], \"cpeApplicability\": [{\"nodes\": [{\"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:isc:bind:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"9.18.50\", \"versionStartIncluding\": \"9.11.0\"}, {\"criteria\": \"cpe:2.3:a:isc:bind:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"9.20.29\", \"versionStartIncluding\": \"9.20.0\"}, {\"criteria\": \"cpe:2.3:a:isc:bind:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"9.21.26\", \"versionStartIncluding\": \"9.21.0\"}, {\"criteria\": \"cpe:2.3:a:isc:bind:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"9.18.50-S1\", \"versionStartIncluding\": \"9.11.3-S1\"}, {\"criteria\": \"cpe:2.3:a:isc:bind:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"9.20.29-S1\", \"versionStartIncluding\": \"9.20.9-S1\"}], \"operator\": \"OR\"}]}], \"providerMetadata\": {\"orgId\": \"404fd4d2-a609-4245-b543-2c944a302a22\", \"shortName\": \"isc\", \"dateUpdated\": \"2026-10-21T12:41:04.379Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-19630\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-10-21T17:19:14.434Z\", \"dateReserved\": \"2026-08-12T15:49:27.570Z\", \"assignerOrgId\": \"404fd4d2-a609-4245-b543-2c944a302a22\", \"datePublished\": \"2026-10-21T12:41:04.379Z\", \"assignerShortName\": \"isc\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…