CVE-2026-16938 (GCVE-0-2026-16938)
Vulnerability from cvelistv5
Published
2026-08-19 18:48
Modified
2026-08-20 15:26
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-862 - Missing Authorization
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in access controls over privileged system configuration operations on the FSP. An attacker with authenticated administrator-level access to the FSP can place the managed system into a non-production operational mode, allowing certain system components to be disabled. This condition persists across FSP resets and requires explicit operator intervention — clearing the affected configuration — to restore normal operation. Successful exploitation results in an availability impact to the managed system.
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| IBM | Power Systems Firmware |
Version: FW1120.00 Version: FW1110.00 ≤ FW1110.30 Version: FW1060.00 ≤ FW1060.80 Version: FW950.00 ≤ FW950.H2 cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-16938",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T15:18:49.285398Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T15:26:35.014Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in access controls over privileged system configuration operations on the FSP. An attacker with authenticated administrator-level access to the FSP can place the managed system into a non-production operational mode, allowing certain system components to be disabled. This condition persists across FSP resets and requires explicit operator intervention \u2014 clearing the affected configuration \u2014 to restore normal operation. Successful exploitation results in an availability impact to the managed system.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in access controls over privileged system configuration operations on the FSP. An attacker with authenticated administrator-level access to the FSP can place the managed system into a non-production operational mode, allowing certain system components to be disabled. This condition persists across FSP resets and requires explicit operator intervention \u2014 clearing the affected configuration \u2014 to restore normal operation. Successful exploitation results in an availability impact to the managed system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862 Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:59:17.561Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283896"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\n\n\n\nPower9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Missing Authorization",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eProtect access to the FSP\u0027s administrative interface.\u003c/p\u003e"
}
],
"value": "Protect access to the FSP\u0027s administrative interface."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-16938",
"datePublished": "2026-08-19T18:48:32.835Z",
"dateReserved": "2026-07-24T07:44:31.605Z",
"dateUpdated": "2026-08-20T15:26:35.014Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…