CVE-2026-16876 (GCVE-0-2026-16876)
Vulnerability from cvelistv5
Published
2026-09-07 00:48
Modified
2026-09-08 15:32
CWE
  • CWE-306 - Missing Authentication for Critical Function
Summary
An authentication bypass vulnerability exists in the WebGUI of Series UNIVERGE IX-R/IX-V. A user could bypass authentication and execute arbitrary CLI commands by tampering with WebGUI messages and sending them to the device via internet.
Impacted products
Vendor Product Version
NEC Corporation UNIVERGE IX-R/IX-V Version: All versions from Ver1.1 through Ver1.3, All versions from Ver1.4.21 through Ver1.4.28 and Ver1.5.23
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-16876",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-08T15:32:24.111712Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-08T15:32:48.460Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "UNIVERGE IX-R/IX-V",
          "vendor": "NEC Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions from Ver1.1 through Ver1.3, All versions from Ver1.4.21 through Ver1.4.28 and Ver1.5.23"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Kojiro Enokida of Sophos Ltd."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An authentication bypass vulnerability exists in the WebGUI of Series UNIVERGE IX-R/IX-V. A user could bypass authentication and execute arbitrary CLI commands by tampering with WebGUI messages and sending them to the device via internet."
            }
          ],
          "value": "An authentication bypass vulnerability exists in the WebGUI of Series UNIVERGE IX-R/IX-V. A user could bypass authentication and execute arbitrary CLI commands by tampering with WebGUI messages and sending them to the device via internet."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-07T00:48:01.015Z",
        "orgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
        "shortName": "NEC"
      },
      "references": [
        {
          "url": "https://jpn.nec.com/security-info/secinfo/nv26-005_en.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
    "assignerShortName": "NEC",
    "cveId": "CVE-2026-16876",
    "datePublished": "2026-09-07T00:48:01.015Z",
    "dateReserved": "2026-07-24T04:35:25.244Z",
    "dateUpdated": "2026-09-08T15:32:48.460Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-16876\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-09-08T15:32:24.111712Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-09-08T15:32:29.759Z\"}}], \"cna\": {\"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Kojiro Enokida of Sophos Ltd.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 9.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"LOW\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"NEC Corporation\", \"product\": \"UNIVERGE IX-R/IX-V\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions from Ver1.1 through Ver1.3, All versions from Ver1.4.21 through Ver1.4.28 and Ver1.5.23\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://jpn.nec.com/security-info/secinfo/nv26-005_en.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An authentication bypass vulnerability exists in the WebGUI of Series UNIVERGE IX-R/IX-V. A user could bypass authentication and execute arbitrary CLI commands by tampering with WebGUI messages and sending them to the device via internet.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"An authentication bypass vulnerability exists in the WebGUI of Series UNIVERGE IX-R/IX-V. A user could bypass authentication and execute arbitrary CLI commands by tampering with WebGUI messages and sending them to the device via internet.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306: Missing Authentication for Critical Function\"}]}], \"providerMetadata\": {\"orgId\": \"f2760a35-e0d8-4637-ac4c-cc1a2de3e282\", \"shortName\": \"NEC\", \"dateUpdated\": \"2026-09-07T00:48:01.015Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-16876\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-09-08T15:32:48.460Z\", \"dateReserved\": \"2026-07-24T04:35:25.244Z\", \"assignerOrgId\": \"f2760a35-e0d8-4637-ac4c-cc1a2de3e282\", \"datePublished\": \"2026-09-07T00:48:01.015Z\", \"assignerShortName\": \"NEC\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…