Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact.
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| IBM | Power Systems Firmware |
Version: FW1120.00 Version: FW1110.00 ≤ FW1110.30 Version: FW1060.00 ≤ FW1060.80 Version: FW950.00 ≤ FW950.H2 cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-16832",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-22T03:56:07.011Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:58:53.948Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283895"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\n\n\n\nPower9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Buffer Overflow",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eProtect access to the FSP\u0027s network interface.\u003c/p\u003e"
}
],
"value": "Protect access to the FSP\u0027s network interface."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-16832",
"datePublished": "2026-08-19T18:49:27.791Z",
"dateReserved": "2026-07-24T02:37:40.718Z",
"dateUpdated": "2026-08-22T03:56:07.011Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-16832\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-08-19T19:21:37.650586Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-08-19T19:21:47.504Z\"}}], \"cna\": {\"title\": \"Power System Buffer Overflow\", \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.4, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*\", \"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*\", \"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*\", \"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*\", \"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*\", \"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*\", \"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*\"], \"vendor\": \"IBM\", \"product\": \"Power Systems Firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"FW1120.00\"}, {\"status\": \"affected\", \"version\": \"FW1110.00\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"FW1110.30\"}, {\"status\": \"affected\", \"version\": \"FW1060.00\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"FW1060.80\"}, {\"status\": \"affected\", \"version\": \"FW950.00\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"FW950.H2\"}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\\n\\n\\n\\nPower 11\\n1) IBM Power System E1180 (9080-HEU)\\n\\n\\n\\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\\n\\n\\n\\nPower 10\\n1) IBM Power System E1080 (9080-HEX)\\n\\n\\n\\nCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\\n\\n\\n\\nPower9\\n1) IBM Power System S922 (9009-22G)\\n2) IBM Power System H922 (9223-22S)\\n3) IBM Power System S914 (9009-41G)\\n4) IBM Power System S924 (9009-42G)\\n5) IBM Power System H924 (9223-42S)\\n6) IBM Power System E950 (9040-MR9)\\n7) IBM Power System E980 (9080-M9S)\\n\\n\\n\\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\\\"https://www.ibm.com/support/fixcentral/\\\" rel=\\\"nofollow\\\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://www.ibm.com/support/pages/node/7283895\", \"tags\": [\"vendor-advisory\", \"patch\"]}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"Protect access to the FSP\u0027s network interface.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eProtect access to the FSP\u0027s network interface.\u003c/p\u003e\", \"base64\": false}]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121 Stack-based Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"9a959283-ebb5-44b6-b705-dcc2bbced522\", \"shortName\": \"ibm\", \"dateUpdated\": \"2026-08-19T18:58:53.948Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-16832\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-08-22T03:56:07.011Z\", \"dateReserved\": \"2026-07-24T02:37:40.718Z\", \"assignerOrgId\": \"9a959283-ebb5-44b6-b705-dcc2bbced522\", \"datePublished\": \"2026-08-19T18:49:27.791Z\", \"assignerShortName\": \"ibm\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.