Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker with network access can send the FSP a malformed request, allowing arbitrary code execution, giving the attacker full control over the managed system, resulting in a confidentiality, integrity, and availability impact.
References
Impacted products
Vendor Product Version
IBM Power Systems Firmware Version: FW1120.00
Version: FW1110.00    FW1110.30
Version: FW1060.00    FW1060.80
Version: FW950.00    FW950.H2
    cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*
    cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*
    cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*
    cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*
    cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*
    cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*
    cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-16687",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-21T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-22T03:56:02.086Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
            "cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
            "cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
            "cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
            "cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
            "cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
            "cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
          ],
          "product": "Power Systems Firmware",
          "vendor": "IBM",
          "versions": [
            {
              "status": "affected",
              "version": "FW1120.00"
            },
            {
              "lessThanOrEqual": "FW1110.30",
              "status": "affected",
              "version": "FW1110.00",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "FW1060.80",
              "status": "affected",
              "version": "FW1060.00",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "FW950.H2",
              "status": "affected",
              "version": "FW950.00",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2  is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker with network access can send the FSP a malformed request, allowing arbitrary code execution, giving the attacker full control over the managed system, resulting in a confidentiality, integrity, and availability impact.\u003c/p\u003e"
            }
          ],
          "value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2  is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker with network access can send the FSP a malformed request, allowing arbitrary code execution, giving the attacker full control over the managed system, resulting in a confidentiality, integrity, and availability impact."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-19T18:56:55.611Z",
        "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "shortName": "ibm"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://www.ibm.com/support/pages/node/7283893"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eIBM strongly recommends customers with the products below install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability as soon as possible.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eIBM strongly recommends customers with the products below install FW1060.81(1060_184) or newer to remediate this vulnerability as soon as possible.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eIBM strongly recommends customers with the products below install FW950.H3(950_230) or newer to remediate this vulnerability as soon as possible.\u003c/p\u003e\u003cp\u003ePower 9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"noopener noreferrer nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
            }
          ],
          "value": "IBM strongly recommends customers with the products below install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability as soon as possible.\nPower 11\n1) IBM Power System E1180 (9080-HEU)\nIBM strongly recommends customers with the products below install FW1060.81(1060_184) or newer to remediate this vulnerability as soon as possible.\nPower 10\n1) IBM Power System E1080 (9080-HEX)\nIBM strongly recommends customers with the products below install FW950.H3(950_230) or newer to remediate this vulnerability as soon as possible.\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
        }
      ],
      "title": "Power System Buffer Overflow",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eProtect access to the FSP\u0027s network interface.\u003c/p\u003e"
            }
          ],
          "value": "Protect access to the FSP\u0027s network interface."
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
    "assignerShortName": "ibm",
    "cveId": "CVE-2026-16687",
    "datePublished": "2026-08-19T18:56:41.912Z",
    "dateReserved": "2026-07-23T00:09:08.103Z",
    "dateUpdated": "2026-08-22T03:56:02.086Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-16687\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-08-20T15:18:32.599208Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-08-20T15:25:55.328Z\"}}], \"cna\": {\"title\": \"Power System Buffer Overflow\", \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 9.6, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*\", \"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*\", \"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*\", \"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*\", \"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*\", \"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*\", \"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*\"], \"vendor\": \"IBM\", \"product\": \"Power Systems Firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"FW1120.00\"}, {\"status\": \"affected\", \"version\": \"FW1110.00\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"FW1110.30\"}, {\"status\": \"affected\", \"version\": \"FW1060.00\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"FW1060.80\"}, {\"status\": \"affected\", \"version\": \"FW950.00\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"FW950.H2\"}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"IBM strongly recommends customers with the products below install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability as soon as possible.\\nPower 11\\n1) IBM Power System E1180 (9080-HEU)\\nIBM strongly recommends customers with the products below install FW1060.81(1060_184) or newer to remediate this vulnerability as soon as possible.\\nPower 10\\n1) IBM Power System E1080 (9080-HEX)\\nIBM strongly recommends customers with the products below install FW950.H3(950_230) or newer to remediate this vulnerability as soon as possible.\\nPower 9\\n1) IBM Power System S922 (9009-22G)\\n2) IBM Power System H922 (9223-22S)\\n3) IBM Power System S914 (9009-41G)\\n4) IBM Power System S924 (9009-42G)\\n5) IBM Power System H924 (9223-42S)\\n6) IBM Power System E950 (9040-MR9)\\n7) IBM Power System E980 (9080-M9S)\\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eIBM strongly recommends customers with the products below install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability as soon as possible.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eIBM strongly recommends customers with the products below install FW1060.81(1060_184) or newer to remediate this vulnerability as soon as possible.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eIBM strongly recommends customers with the products below install FW950.H3(950_230) or newer to remediate this vulnerability as soon as possible.\u003c/p\u003e\u003cp\u003ePower 9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\\\"https://www.ibm.com/support/fixcentral/\\\" rel=\\\"noopener noreferrer nofollow\\\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://www.ibm.com/support/pages/node/7283893\", \"tags\": [\"vendor-advisory\", \"patch\"]}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"Protect access to the FSP\u0027s network interface.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eProtect access to the FSP\u0027s network interface.\u003c/p\u003e\", \"base64\": false}]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2  is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker with network access can send the FSP a malformed request, allowing arbitrary code execution, giving the attacker full control over the managed system, resulting in a confidentiality, integrity, and availability impact.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2  is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker with network access can send the FSP a malformed request, allowing arbitrary code execution, giving the attacker full control over the managed system, resulting in a confidentiality, integrity, and availability impact.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121 Stack-based Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"9a959283-ebb5-44b6-b705-dcc2bbced522\", \"shortName\": \"ibm\", \"dateUpdated\": \"2026-08-19T18:56:55.611Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-16687\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-08-22T03:56:02.086Z\", \"dateReserved\": \"2026-07-23T00:09:08.103Z\", \"assignerOrgId\": \"9a959283-ebb5-44b6-b705-dcc2bbced522\", \"datePublished\": \"2026-08-19T18:56:41.912Z\", \"assignerShortName\": \"ibm\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…