CVE-2026-124577 (GCVE-0-2026-124577)
Vulnerability from cvelistv5 – Published: 2026-11-09 07:15 – Updated: 2026-11-09 07:15
VLAI
EPSS
VEX
Title
Intelbras SG 2404 PoE L2+ Web Management EXCU_SHELL improper authentication
Summary
A weakness has been identified in Intelbras SG 2404 PoE L2+ 1.00.70/1.00.72. The affected element is an unknown function of the file /EXCU_SHELL of the component Web Management Interface. Executing a manipulation can lead to improper authentication. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks. Upgrading to version 1.00.74 is sufficient to fix this issue. Upgrading the affected component is advised.
Severity
9.8 (Critical)
9.8 (Critical)
CWE
- CWE-287 - Improper Authentication
Assigner
VulDB
CNA
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/432923 | vdb-entry |
| https://vuldb.com/vuln/432923/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-124577 | third-party-advisory |
| https://vuldb.com/submit/1038184 | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Intelbras | SG 2404 PoE L2+ |
Affected:
1.00.70
Affected: 1.00.72 Unaffected: 1.00.74 cpe:2.3:h:intelbras:sg_2404_poe_l2_:*:*:*:*:*:*:*:* |
{
"containers": {
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:intelbras:sg_2404_poe_l2_:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "SG 2404 PoE L2+",
"vendor": "Intelbras",
"versions": [
{
"status": "affected",
"version": "1.00.70"
},
{
"status": "affected",
"version": "1.00.72"
},
{
"status": "unaffected",
"version": "1.00.74"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "JoasHS (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB Vulnerability Moderation Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Intelbras SG 2404 PoE L2+ 1.00.70/1.00.72. The affected element is an unknown function of the file /EXCU_SHELL of the component Web Management Interface. Executing a manipulation can lead to improper authentication. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks. Upgrading to version 1.00.74 is sufficient to fix this issue. Upgrading the affected component is advised."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 10,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:OF/RC:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T07:15:16.393Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-432923 | Intelbras SG 2404 PoE L2+ Web Management EXCU_SHELL improper authentication",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/vuln/432923"
},
{
"name": "VDB-432923 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/432923/cti"
},
{
"name": "CVE-2026-124577 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-124577"
},
{
"name": "Submit #1038184 | Intelbras SG 2404 PoE L2+ managed switch Firmware 1.00.70, 1.00.72 (hardware B1) Authentication bypass in web management interface allows unauthenticated execution of privileged CLI commands via /EXCU_SHELL",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/1038184"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-11-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-11-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-11-08T18:07:25.000Z",
"value": "VulDB entry last update"
}
],
"title": "Intelbras SG 2404 PoE L2+ Web Management EXCU_SHELL improper authentication",
"x_generator": [
"VulDB PVTS v202611"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-124577",
"datePublished": "2026-11-09T07:15:16.393Z",
"dateReserved": "2026-11-08T17:02:20.350Z",
"dateUpdated": "2026-11-09T07:15:16.393Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.