CVE-2026-11889 (GCVE-0-2026-11889)
Vulnerability from cvelistv5 – Published: 2026-07-16 20:38 – Updated: 2026-07-17 13:21
VLAI
EPSS
VEX
Title
SALTO ProAccess Space Authorization Bypass Through User-Controlled Key
Summary
SALTO ProAccess Space software using the tenancy feature / logical
partition is vulnerable to a privilege escalation attack that could
allow an authorized attacker to access any space managed by the affected
product.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-17 13:21 UTC
CWE
Assigner
icscert
CNA
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| SALTO | ProAccess Space |
Affected:
0 , < 6.13
(custom)
Unaffected: 6.13 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11889",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-17T13:21:04.700942Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-17T13:21:12.776Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ProAccess Space",
"vendor": "SALTO",
"versions": [
{
"lessThan": "6.13",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "6.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bernhard Lorenz of Limes Security reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SALTO ProAccess Space software using the tenancy feature / logical \npartition is vulnerable to a privilege escalation attack that could \nallow an authorized attacker to access any space managed by the affected\n product."
}
],
"value": "SALTO ProAccess Space software using the tenancy feature / logical \npartition is vulnerable to a privilege escalation attack that could \nallow an authorized attacker to access any space managed by the affected\n product."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-16T20:38:46.479Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-197-07"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-197-07.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUsers of SALTO ProAccess using the tenancy feature should upgrade to version 6.13.\u003c/p\u003e\u003cp\u003eTo further enhance security after \napplying the update:\u0026nbsp;\u003c/p\u003e\u003col\u003e\u003cli\u003eOperate ProAccess Space on a protected internal \nnetwork and avoid exposing it directly to the Internet.\u0026nbsp;\u003c/li\u003e\u003cli\u003eRestrict \noperator-level accounts to the minimum required and apply \nleast-privilege principles.\u0026nbsp;\u003c/li\u003e\u003cli\u003eIf feasible, disable the partitioning \nfeature and operate under a single partition.\u0026nbsp;\u003c/li\u003e\u003cli\u003eWhen strong tenant \nseparation is required, consider running separate Space instances \n(isolated environments) rather than relying solely on logical \npartitioning.\u003c/li\u003e\u003c/ol\u003e"
}
],
"value": "Users of SALTO ProAccess using the tenancy feature should upgrade to version 6.13.\n\n\n\nTo further enhance security after \napplying the update:\u00a0\n\n * Operate ProAccess Space on a protected internal \nnetwork and avoid exposing it directly to the Internet.\u00a0\n * Restrict \noperator-level accounts to the minimum required and apply \nleast-privilege principles.\u00a0\n * If feasible, disable the partitioning \nfeature and operate under a single partition.\u00a0\n * When strong tenant \nseparation is required, consider running separate Space instances \n(isolated environments) rather than relying solely on logical \npartitioning."
}
],
"source": {
"advisory": "ICSA-26-197-07",
"discovery": "EXTERNAL"
},
"title": "SALTO ProAccess Space Authorization Bypass Through User-Controlled Key",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-11889",
"datePublished": "2026-07-16T20:38:46.479Z",
"dateReserved": "2026-06-10T14:40:08.574Z",
"dateUpdated": "2026-07-17T13:21:12.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11889",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-17T13:21:04.700942Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-17T13:21:08.842Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ProAccess Space",
"vendor": "SALTO",
"versions": [
{
"lessThan": "6.13",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "6.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bernhard Lorenz of Limes Security reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SALTO ProAccess Space software using the tenancy feature / logical \npartition is vulnerable to a privilege escalation attack that could \nallow an authorized attacker to access any space managed by the affected\n product."
}
],
"value": "SALTO ProAccess Space software using the tenancy feature / logical \npartition is vulnerable to a privilege escalation attack that could \nallow an authorized attacker to access any space managed by the affected\n product."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-16T20:38:46.479Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-197-07"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-197-07.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUsers of SALTO ProAccess using the tenancy feature should upgrade to version 6.13.\u003c/p\u003e\u003cp\u003eTo further enhance security after \napplying the update:\u0026nbsp;\u003c/p\u003e\u003col\u003e\u003cli\u003eOperate ProAccess Space on a protected internal \nnetwork and avoid exposing it directly to the Internet.\u0026nbsp;\u003c/li\u003e\u003cli\u003eRestrict \noperator-level accounts to the minimum required and apply \nleast-privilege principles.\u0026nbsp;\u003c/li\u003e\u003cli\u003eIf feasible, disable the partitioning \nfeature and operate under a single partition.\u0026nbsp;\u003c/li\u003e\u003cli\u003eWhen strong tenant \nseparation is required, consider running separate Space instances \n(isolated environments) rather than relying solely on logical \npartitioning.\u003c/li\u003e\u003c/ol\u003e"
}
],
"value": "Users of SALTO ProAccess using the tenancy feature should upgrade to version 6.13.\n\n\n\nTo further enhance security after \napplying the update:\u00a0\n\n * Operate ProAccess Space on a protected internal \nnetwork and avoid exposing it directly to the Internet.\u00a0\n * Restrict \noperator-level accounts to the minimum required and apply \nleast-privilege principles.\u00a0\n * If feasible, disable the partitioning \nfeature and operate under a single partition.\u00a0\n * When strong tenant \nseparation is required, consider running separate Space instances \n(isolated environments) rather than relying solely on logical \npartitioning."
}
],
"source": {
"advisory": "ICSA-26-197-07",
"discovery": "EXTERNAL"
},
"title": "SALTO ProAccess Space Authorization Bypass Through User-Controlled Key",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-11889",
"datePublished": "2026-07-16T20:38:46.479Z",
"dateReserved": "2026-06-10T14:40:08.574Z",
"dateUpdated": "2026-07-17T13:21:12.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.