CVE-2026-103792 (GCVE-0-2026-103792)
Vulnerability from cvelistv5
Published
2026-10-28 10:26
Modified
2026-10-28 10:26
Severity ?
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
Dell PowerProtect Data Domain Management Center, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access to managed systems.
Impacted products
Vendor Product Version
Dell PowerProtect Data Domain Management Center Version: 0   ≤
Version: 0   ≤
Version: 0   ≤
Version: 0   ≤
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Domain Management Center",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "8.9.0.0 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "7.13.1.90 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "8.3.1.50 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "8.6.1.30 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2026-10-19T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Domain Management Center, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain an Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access to managed systems."
            }
          ],
          "value": "Dell PowerProtect Data Domain Management Center, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain an Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access to managed systems."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-28T10:26:41.330Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000515178/dsa-2026-416-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2026-103792",
    "datePublished": "2026-10-28T10:26:41.330Z",
    "dateReserved": "2026-10-01T11:04:15.916Z",
    "dateUpdated": "2026-10-28T10:26:41.330Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…