CVE-2025-9998 (GCVE-0-2025-9998)
Vulnerability from cvelistv5
Published
2025-09-05 16:40
Modified
2026-02-26 07:54
CWE
  • CWE-754 - Improper Check for Unusual or Exceptional Conditions
Summary
The sequence of packets received by a Networking server are not correctly checked. An attacker could exploit this vulnerability to send specially crafted messages to force the application to stop.
References
Impacted products
Vendor Product Version
arcinfo PcVue Version: 16.0.0
Version: 15.0.0
Version: 12.0.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9998",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-05T17:51:03.059305Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-05T17:51:49.768Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "modules": [
            "Networking"
          ],
          "product": "PcVue",
          "vendor": "arcinfo",
          "versions": [
            {
              "lessThanOrEqual": "16.3.3",
              "status": "affected",
              "version": "16.0.0",
              "versionType": "cpe"
            },
            {
              "lessThanOrEqual": "15.2.12",
              "status": "affected",
              "version": "15.0.0",
              "versionType": "cpe"
            },
            {
              "lessThanOrEqual": "12.0.31",
              "status": "affected",
              "version": "12.0.0",
              "versionType": "cpe"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "16.3.3",
                  "versionStartIncluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "15.2.12",
                  "versionStartIncluding": "15.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "12.0.31",
                  "versionStartIncluding": "12.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Guillaume Andr\u00e9 (Synacktiv)"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Pierre Gertner (Synacktiv)"
        }
      ],
      "datePublic": "2025-09-04T22:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The sequence of packets received by a Networking server are not correctly checked.\u003cbr\u003e\u003cbr\u003eAn attacker could exploit this vulnerability to send specially crafted messages to force the application to stop.\u003cbr\u003e"
            }
          ],
          "value": "The sequence of packets received by a Networking server are not correctly checked.\n\nAn attacker could exploit this vulnerability to send specially crafted messages to force the application to stop."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "No POC available."
            }
          ],
          "value": "No POC available."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Not known to be exploited"
            }
          ],
          "value": "Not known to be exploited"
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "USER",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "GREEN",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:Green",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "MODERATE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "other": {
            "content": {
              "options": [
                {
                  "Exploitation": "none"
                },
                {
                  "Automatable": "yes"
                },
                {
                  "Technical Impact": "partial"
                }
              ],
              "role": "CNA",
              "version": "2.0.3"
            },
            "type": "ssvc"
          },
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-26T07:54:07.047Z",
        "orgId": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
        "shortName": "arcinfo"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.pcvue.com/security/#SB2025-4"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cb\u003eHarden the configuration\u003c/b\u003e\u003cbr\u003e\u003cu\u003eWho should apply this recommendation:\u003c/u\u003e All users\u003cbr\u003eTo reduce the risk of exploitation, ARC Informatique strongly recommends implementing the following defensive measures:\u003cbr\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from unsecure networks.\u003c/li\u003e\u003cli\u003eLocate control system networks and remote devices behind firewalls and isolate them from business networks.\u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\u003cb\u003eUpdate PcVue\u003c/b\u003e\u003cbr\u003e\u003cu\u003eWho should apply this recommendation:\u003c/u\u003e All users running affected components.\u003cbr\u003eApply the patch by installing a fixed PcVue version.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eA fixed release must be installed on all stations for the fix to be fully applied.\u003c/b\u003e\u003cbr\u003eExisting projects require a settings update for the fix to be applied. The complete update procedure and verification steps are described in the Knowledge Base article KB1254\n\n(\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.pcvue.com/?post_type=post\u0026amp;s=\u0026amp;kbase_id=kb1254\"\u003ehttps://www.pcvue.com/?post_type=post\u0026amp;s=\u0026amp;kbase_id=kb1254\u003c/a\u003e)\n\n.\u003cbr\u003eFor new projects, the settings are configured by default with secured values.\u003cbr\u003e\u003cbr\u003eTo verify that the patch has been applied correctly, the user must check that:\u003cbr\u003e\u003cul\u003e\u003cli\u003eThe \u003ci\u003eFile version\u003c/i\u003e property of the file \u003ci\u003e./bin/sv32.exe\u003c/i\u003e matches the deployed release or later, and ensure that any earlier release is no longer used;\u003c/li\u003e\u003cli\u003eThe \u003ci\u003eInteroperability issues\u003c/i\u003e settings of the Networking feature are disabled.\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\u003cbr\u003e\n\n\u003cb\u003eAvailable patches:\u003c/b\u003e\u003cbr\u003ePatch provided in:\u003cbr\u003e\u003cul\u003e\u003cli\u003ePcVue 16.3.4 (16.3.4902.3112)\u003c/li\u003e\u003cli\u003ePcVue 15.2.13 (15.2.13902.37126)\u003c/li\u003e\u003cli\u003ePcVue 12.0.32 (12.0.32900.37130)\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Harden the configuration\nWho should apply this recommendation: All users\nTo reduce the risk of exploitation, ARC Informatique strongly recommends implementing the following defensive measures:\n  *  Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from unsecure networks.\n  *  Locate control system networks and remote devices behind firewalls and isolate them from business networks.\n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\n\n\n\nUpdate PcVue\nWho should apply this recommendation: All users running affected components.\nApply the patch by installing a fixed PcVue version.\n\nA fixed release must be installed on all stations for the fix to be fully applied.\nExisting projects require a settings update for the fix to be applied. The complete update procedure and verification steps are described in the Knowledge Base article KB1254\n\n( https://www.pcvue.com/?post_type=post\u0026s=\u0026kbase_id=kb1254 )\n\n.\nFor new projects, the settings are configured by default with secured values.\n\nTo verify that the patch has been applied correctly, the user must check that:\n  *  The File version property of the file ./bin/sv32.exe matches the deployed release or later, and ensure that any earlier release is no longer used;\n  *  The Interoperability issues settings of the Networking feature are disabled.\n\n\n\n\n\n\nAvailable patches:\nPatch provided in:\n  *  PcVue 16.3.4 (16.3.4902.3112)\n  *  PcVue 15.2.13 (15.2.13902.37126)\n  *  PcVue 12.0.32 (12.0.32900.37130)"
        }
      ],
      "source": {
        "advisory": "SB2025-4",
        "discovery": "EXTERNAL"
      },
      "title": "Improper validation of packets sequencing",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
    "assignerShortName": "arcinfo",
    "cveId": "CVE-2025-9998",
    "datePublished": "2025-09-05T16:40:13.645Z",
    "dateReserved": "2025-09-04T16:34:22.785Z",
    "dateUpdated": "2026-02-26T07:54:07.047Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-9998\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-05T17:51:03.059305Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-05T17:51:06.873Z\"}}], \"cna\": {\"title\": \"Improper validation of packets sequencing\", \"source\": {\"advisory\": \"SB2025-4\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Guillaume Andr\\u00e9 (Synacktiv)\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Pierre Gertner (Synacktiv)\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"USER\", \"baseScore\": 6, \"Automatable\": \"YES\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:Green\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"GREEN\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"LOW\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"MODERATE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"role\": \"CNA\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\"}}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"arcinfo\", \"modules\": [\"Networking\"], \"product\": \"PcVue\", \"versions\": [{\"status\": \"affected\", \"version\": \"16.0.0\", \"versionType\": \"cpe\", \"lessThanOrEqual\": \"16.3.3\"}, {\"status\": \"affected\", \"version\": \"15.0.0\", \"versionType\": \"cpe\", \"lessThanOrEqual\": \"15.2.12\"}, {\"status\": \"affected\", \"version\": \"12.0.0\", \"versionType\": \"cpe\", \"lessThanOrEqual\": \"12.0.31\"}], \"defaultStatus\": \"affected\"}], \"exploits\": [{\"lang\": \"en\", \"value\": \"No POC available.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"No POC available.\", \"base64\": false}]}, {\"lang\": \"en\", \"value\": \"Not known to be exploited\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Not known to be exploited\", \"base64\": false}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Harden the configuration\\nWho should apply this recommendation: All users\\nTo reduce the risk of exploitation, ARC Informatique strongly recommends implementing the following defensive measures:\\n  *  Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from unsecure networks.\\n  *  Locate control system networks and remote devices behind firewalls and isolate them from business networks.\\n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\\n\\n\\n\\nUpdate PcVue\\nWho should apply this recommendation: All users running affected components.\\nApply the patch by installing a fixed PcVue version.\\n\\nA fixed release must be installed on all stations for the fix to be fully applied.\\nExisting projects require a settings update for the fix to be applied. The complete update procedure and verification steps are described in the Knowledge Base article KB1254\\n\\n( https://www.pcvue.com/?post_type=post\u0026s=\u0026kbase_id=kb1254 )\\n\\n.\\nFor new projects, the settings are configured by default with secured values.\\n\\nTo verify that the patch has been applied correctly, the user must check that:\\n  *  The File version property of the file ./bin/sv32.exe matches the deployed release or later, and ensure that any earlier release is no longer used;\\n  *  The Interoperability issues settings of the Networking feature are disabled.\\n\\n\\n\\n\\n\\n\\nAvailable patches:\\nPatch provided in:\\n  *  PcVue 16.3.4 (16.3.4902.3112)\\n  *  PcVue 15.2.13 (15.2.13902.37126)\\n  *  PcVue 12.0.32 (12.0.32900.37130)\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cb\u003eHarden the configuration\u003c/b\u003e\u003cbr\u003e\u003cu\u003eWho should apply this recommendation:\u003c/u\u003e All users\u003cbr\u003eTo reduce the risk of exploitation, ARC Informatique strongly recommends implementing the following defensive measures:\u003cbr\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from unsecure networks.\u003c/li\u003e\u003cli\u003eLocate control system networks and remote devices behind firewalls and isolate them from business networks.\u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\u003cb\u003eUpdate PcVue\u003c/b\u003e\u003cbr\u003e\u003cu\u003eWho should apply this recommendation:\u003c/u\u003e All users running affected components.\u003cbr\u003eApply the patch by installing a fixed PcVue version.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eA fixed release must be installed on all stations for the fix to be fully applied.\u003c/b\u003e\u003cbr\u003eExisting projects require a settings update for the fix to be applied. The complete update procedure and verification steps are described in the Knowledge Base article KB1254\\n\\n(\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.pcvue.com/?post_type=post\u0026amp;s=\u0026amp;kbase_id=kb1254\\\"\u003ehttps://www.pcvue.com/?post_type=post\u0026amp;s=\u0026amp;kbase_id=kb1254\u003c/a\u003e)\\n\\n.\u003cbr\u003eFor new projects, the settings are configured by default with secured values.\u003cbr\u003e\u003cbr\u003eTo verify that the patch has been applied correctly, the user must check that:\u003cbr\u003e\u003cul\u003e\u003cli\u003eThe \u003ci\u003eFile version\u003c/i\u003e property of the file \u003ci\u003e./bin/sv32.exe\u003c/i\u003e matches the deployed release or later, and ensure that any earlier release is no longer used;\u003c/li\u003e\u003cli\u003eThe \u003ci\u003eInteroperability issues\u003c/i\u003e settings of the Networking feature are disabled.\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\u003cbr\u003e\\n\\n\u003cb\u003eAvailable patches:\u003c/b\u003e\u003cbr\u003ePatch provided in:\u003cbr\u003e\u003cul\u003e\u003cli\u003ePcVue 16.3.4 (16.3.4902.3112)\u003c/li\u003e\u003cli\u003ePcVue 15.2.13 (15.2.13902.37126)\u003c/li\u003e\u003cli\u003ePcVue 12.0.32 (12.0.32900.37130)\u003c/li\u003e\u003c/ul\u003e\", \"base64\": false}]}], \"datePublic\": \"2025-09-04T22:00:00.000Z\", \"references\": [{\"url\": \"https://www.pcvue.com/security/#SB2025-4\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The sequence of packets received by a Networking server are not correctly checked.\\n\\nAn attacker could exploit this vulnerability to send specially crafted messages to force the application to stop.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The sequence of packets received by a Networking server are not correctly checked.\u003cbr\u003e\u003cbr\u003eAn attacker could exploit this vulnerability to send specially crafted messages to force the application to stop.\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-754\", \"description\": \"CWE-754 Improper Check for Unusual or Exceptional Conditions\"}]}], \"cpeApplicability\": [{\"nodes\": [{\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"16.3.3\", \"versionStartIncluding\": \"16.0.0\"}, {\"criteria\": \"cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"15.2.12\", \"versionStartIncluding\": \"15.0.0\"}, {\"criteria\": \"cpe:2.3:a:arcinfo:pcvue:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"12.0.31\", \"versionStartIncluding\": \"12.0.0\"}], \"operator\": \"OR\"}], \"operator\": \"OR\"}], \"providerMetadata\": {\"orgId\": \"87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932\", \"shortName\": \"arcinfo\", \"dateUpdated\": \"2026-02-26T07:54:07.047Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-9998\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-02-26T07:54:07.047Z\", \"dateReserved\": \"2025-09-04T16:34:22.785Z\", \"assignerOrgId\": \"87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932\", \"datePublished\": \"2025-09-05T16:40:13.645Z\", \"assignerShortName\": \"arcinfo\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…