CVE-2025-8321 (GCVE-0-2025-8321)
Vulnerability from cvelistv5
Published
2025-07-30 00:50
Modified
2025-07-30 13:48
CWE
  • CWE-1328 - Security Version Number Mutable to Older Versions
Summary
Tesla Wall Connector Firmware Downgrade Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Tesla Wall Connector devices. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware upgrade feature. The issue results from the lack of an anti-downgrade mechanism. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-26299.
References
Impacted products
Vendor Product Version
Tesla Wall Connector Version: 24.44.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8321",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-30T13:47:20.207388Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-30T13:48:29.568Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Wall Connector",
          "vendor": "Tesla",
          "versions": [
            {
              "status": "affected",
              "version": "24.44.1"
            }
          ]
        }
      ],
      "dateAssigned": "2025-07-30T00:48:45.751Z",
      "datePublic": "2025-07-30T00:49:55.241Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Tesla Wall Connector Firmware Downgrade Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Tesla Wall Connector devices. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the firmware upgrade feature. The issue results from the lack of an anti-downgrade mechanism. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-26299."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1328",
              "description": "CWE-1328: Security Version Number Mutable to Older Versions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-30T00:50:04.326Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-25-712",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-712/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "Synacktiv"
      },
      "title": "Tesla Wall Connector Firmware Downgrade Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2025-8321",
    "datePublished": "2025-07-30T00:50:04.326Z",
    "dateReserved": "2025-07-30T00:48:45.723Z",
    "dateUpdated": "2025-07-30T13:48:29.568Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-8321\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-07-30T13:47:20.207388Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-07-30T13:48:06.628Z\"}}], \"cna\": {\"title\": \"Tesla Wall Connector Firmware Downgrade Vulnerability\", \"source\": {\"lang\": \"en\", \"value\": \"Synacktiv\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.8, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\"}}], \"affected\": [{\"vendor\": \"Tesla\", \"product\": \"Wall Connector\", \"versions\": [{\"status\": \"affected\", \"version\": \"24.44.1\"}], \"defaultStatus\": \"unknown\"}], \"datePublic\": \"2025-07-30T00:49:55.241Z\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-25-712/\", \"name\": \"ZDI-25-712\", \"tags\": [\"x_research-advisory\"]}], \"dateAssigned\": \"2025-07-30T00:48:45.751Z\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"Tesla Wall Connector Firmware Downgrade Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Tesla Wall Connector devices. Authentication is not required to exploit this vulnerability.\\n\\nThe specific flaw exists within the firmware upgrade feature. The issue results from the lack of an anti-downgrade mechanism. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-26299.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1328\", \"description\": \"CWE-1328: Security Version Number Mutable to Older Versions\"}]}], \"providerMetadata\": {\"orgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"shortName\": \"zdi\", \"dateUpdated\": \"2025-07-30T00:50:04.326Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-8321\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-07-30T13:48:29.568Z\", \"dateReserved\": \"2025-07-30T00:48:45.723Z\", \"assignerOrgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"datePublished\": \"2025-07-30T00:50:04.326Z\", \"assignerShortName\": \"zdi\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…