CVE-2025-6549 (GCVE-0-2025-6549)
Vulnerability from cvelistv5
Published
2025-07-11 15:11
Modified
2025-07-11 15:38
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
6.9 (Medium) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/AU:Y/R:U/RE:M
6.9 (Medium) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/AU:Y/R:U/RE:M
VLAI Severity ?
EPSS score ?
CWE
- CWE-863 - Incorrect Authorization
Summary
An Incorrect Authorization vulnerability in the web server of Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to reach the
Juniper Web Device Manager
(J-Web).
When Juniper Secure connect (JSC) is enabled on specific interfaces, or multiple interfaces are configured for J-Web, the J-Web UI is reachable over more than the intended interfaces.
This issue affects Junos OS:
* all versions before 21.4R3-S9,
* 22.2 versions before 22.2R3-S5,
* 22.4 versions before 22.4R3-S5,
* 23.2 versions before 23.2R2-S3,
* 23.4 versions before 23.4R2-S5,
* 24.2 versions before 24.2R2.
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Juniper Networks | Junos OS |
Version: 0 ≤ Version: 22.2 ≤ Version: 22.4 ≤ Version: 23.2 ≤ Version: 23.4 ≤ Version: 24.2 ≤ |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6549",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-11T15:38:46.249663Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-11T15:38:56.764Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"SRX Series"
],
"product": "Junos OS",
"vendor": "Juniper Networks",
"versions": [
{
"lessThan": "21.4R3-S9",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "22.2R3-S5",
"status": "affected",
"version": "22.2",
"versionType": "semver"
},
{
"lessThan": "22.4R3-S5",
"status": "affected",
"version": "22.4",
"versionType": "semver"
},
{
"lessThan": "23.2R2-S3",
"status": "affected",
"version": "23.2",
"versionType": "semver"
},
{
"lessThan": "23.4R2-S5",
"status": "affected",
"version": "23.4",
"versionType": "semver"
},
{
"lessThan": "24.2R2",
"status": "affected",
"version": "24.2",
"versionType": "semver"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A system is affected if more than one interface is specified for J-Web:\u003cbr\u003e\u003cbr\u003e\u003ctt\u003e[ system services web-management http(s) \u0026lt;interface\u0026gt; ]\u003c/tt\u003e\u003cbr\u003e\u003cbr\u003eor JSC is configured:\u003cbr\u003e\u003ctt\u003e\u003cbr\u003e[ security ike gateway \u0026lt;ik-gw-name\u0026gt;\u0026nbsp;external-interface \u0026lt;interface\u0026gt; ]\u003c/tt\u003e"
}
],
"value": "A system is affected if more than one interface is specified for J-Web:\n\n[ system services web-management http(s) \u003cinterface\u003e ]\n\nor JSC is configured:\n\n[ security ike gateway \u003cik-gw-name\u003e\u00a0external-interface \u003cinterface\u003e ]"
}
],
"datePublic": "2025-07-09T16:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An Incorrect Authorization vulnerability in the web server of Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to reach the \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eJuniper Web Device Manager\u003c/span\u003e\n\n (J-Web).\u003cbr\u003e\u003cbr\u003eWhen Juniper Secure connect (JSC) is enabled on specific interfaces, or multiple interfaces are configured for J-Web, the J-Web UI is reachable over more than the intended interfaces.\u003cbr\u003e\u003cp\u003eThis issue affects Junos OS:\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eall versions before 21.4R3-S9,\u003c/li\u003e\u003cli\u003e22.2 versions before 22.2R3-S5,\u003c/li\u003e\u003cli\u003e22.4 versions before 22.4R3-S5,\u003c/li\u003e\u003cli\u003e23.2 versions before 23.2R2-S3,\u003c/li\u003e\u003cli\u003e23.4 versions before 23.4R2-S5,\u003c/li\u003e\u003cli\u003e24.2 versions before 24.2R2.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
}
],
"value": "An Incorrect Authorization vulnerability in the web server of Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to reach the \n\nJuniper Web Device Manager\n\n (J-Web).\n\nWhen Juniper Secure connect (JSC) is enabled on specific interfaces, or multiple interfaces are configured for J-Web, the J-Web UI is reachable over more than the intended interfaces.\nThis issue affects Junos OS:\n\n\n\n * all versions before 21.4R3-S9,\n * 22.2 versions before 22.2R3-S5,\n * 22.4 versions before 22.4R3-S5,\n * 23.2 versions before 23.2R2-S3,\n * 23.4 versions before 23.4R2-S5,\n * 24.2 versions before 24.2R2."
}
],
"exploits": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
}
],
"value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/AU:Y/R:U/RE:M",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863 Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-11T15:11:04.939Z",
"orgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
"shortName": "juniper"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://supportportal.juniper.net/JSA100098"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The following software releases have been updated to resolve this specific issue: 21.4R3-S9, 22.2R3-S5, 22.4R3-S5, 23.2R2-S3, 23.4R2-S5, 24.2R2, 24.4R1, and all subsequent releases."
}
],
"value": "The following software releases have been updated to resolve this specific issue: 21.4R3-S9, 22.2R3-S5, 22.4R3-S5, 23.2R2-S3, 23.4R2-S5, 24.2R2, 24.4R1, and all subsequent releases."
}
],
"source": {
"advisory": "JSA100098",
"defect": [
"1832831"
],
"discovery": "USER"
},
"title": "Junos OS: SRX Series: J-Web can be exposed on additional interfaces",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "To reduce the risk of exploitation configure a firewall filter on all ingress interfaces over which J-Web is not meant to be reachable or ensure that the resp. security policies don\u0027t allow such connections."
}
],
"value": "To reduce the risk of exploitation configure a firewall filter on all ingress interfaces over which J-Web is not meant to be reachable or ensure that the resp. security policies don\u0027t allow such connections."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
"assignerShortName": "juniper",
"cveId": "CVE-2025-6549",
"datePublished": "2025-07-11T15:11:04.939Z",
"dateReserved": "2025-06-23T19:28:49.259Z",
"dateUpdated": "2025-07-11T15:38:56.764Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…