CVE-2025-6400 (GCVE-0-2025-6400)
Vulnerability from cvelistv5
Published
2025-06-21 05:31
Modified
2025-06-23 19:27
CWE
Summary
A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101 and classified as critical. Affected by this issue is some unknown functionality of the file /boafrm/formPortFw of the component HTTP POST Message Handler. The manipulation of the argument service_type leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
TOTOLINK N300RH Version: 6.1c.1390_B20191101
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-6400",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-23T16:09:32.157775Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-23T19:27:53.229Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/d2pq/cve/blob/main/616/20.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP POST Message Handler"
          ],
          "product": "N300RH",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "6.1c.1390_B20191101"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yuhongxiang (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101 and classified as critical. Affected by this issue is some unknown functionality of the file /boafrm/formPortFw of the component HTTP POST Message Handler. The manipulation of the argument service_type leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in TOTOLINK N300RH 6.1c.1390_B20191101 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um eine nicht exakt ausgemachte Funktion der Datei /boafrm/formPortFw der Komponente HTTP POST Message Handler. Durch Manipulation des Arguments service_type mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-21T05:31:08.158Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-313394 | TOTOLINK N300RH HTTP POST Message formPortFw buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.313394"
        },
        {
          "name": "VDB-313394 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.313394"
        },
        {
          "name": "Submit #597687 | TOTOLINK N300RH_V4 V6.1c.1390_B20191101 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.597687"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/d2pq/cve/blob/main/616/20.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/d2pq/cve/blob/main/616/20.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-20T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-20T12:43:52.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK N300RH HTTP POST Message formPortFw buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-6400",
    "datePublished": "2025-06-21T05:31:08.158Z",
    "dateReserved": "2025-06-20T10:38:45.469Z",
    "dateUpdated": "2025-06-23T19:27:53.229Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-6400\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-23T16:09:32.157775Z\"}}}], \"references\": [{\"url\": \"https://github.com/d2pq/cve/blob/main/616/20.md\", \"tags\": [\"exploit\"]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-23T16:09:33.486Z\"}}], \"cna\": {\"title\": \"TOTOLINK N300RH HTTP POST Message formPortFw buffer overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"yuhongxiang (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"vendor\": \"TOTOLINK\", \"modules\": [\"HTTP POST Message Handler\"], \"product\": \"N300RH\", \"versions\": [{\"status\": \"affected\", \"version\": \"6.1c.1390_B20191101\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-06-20T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-06-20T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-06-20T12:43:52.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.313394\", \"name\": \"VDB-313394 | TOTOLINK N300RH HTTP POST Message formPortFw buffer overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.313394\", \"name\": \"VDB-313394 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.597687\", \"name\": \"Submit #597687 | TOTOLINK N300RH_V4 V6.1c.1390_B20191101 Buffer Overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/d2pq/cve/blob/main/616/20.md\", \"tags\": [\"related\"]}, {\"url\": \"https://github.com/d2pq/cve/blob/main/616/20.md#poc\", \"tags\": [\"exploit\"]}, {\"url\": \"https://www.totolink.net/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101 and classified as critical. Affected by this issue is some unknown functionality of the file /boafrm/formPortFw of the component HTTP POST Message Handler. The manipulation of the argument service_type leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.\"}, {\"lang\": \"de\", \"value\": \"Eine Schwachstelle wurde in TOTOLINK N300RH 6.1c.1390_B20191101 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um eine nicht exakt ausgemachte Funktion der Datei /boafrm/formPortFw der Komponente HTTP POST Message Handler. Durch Manipulation des Arguments service_type mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \\u00fcber das Netzwerk. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-120\", \"description\": \"Buffer Overflow\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-119\", \"description\": \"Memory Corruption\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-06-21T05:31:08.158Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-6400\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-23T19:27:53.229Z\", \"dateReserved\": \"2025-06-20T10:38:45.469Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-06-21T05:31:08.158Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…