CVE-2025-5965 (GCVE-0-2025-5965)
Vulnerability from cvelistv5
Published
2026-01-05 10:06
Modified
2026-01-08 15:43
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.
References
| URL | Tags | |
|---|---|---|
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Centreon | Infra Monitoring |
Version: 25.10.0 ≤ Version: 24.10.0 ≤ Version: 24.04.0 ≤ |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5965",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-05T20:01:00.415596Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-05T20:01:20.692Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Backup configuration in the administration setup"
],
"product": "Infra Monitoring",
"vendor": "Centreon",
"versions": [
{
"lessThan": "25.10.2",
"status": "affected",
"version": "25.10.0",
"versionType": "semver"
},
{
"lessThan": "24.10.15",
"status": "affected",
"version": "24.10.0",
"versionType": "semver"
},
{
"lessThan": "24.04.19",
"status": "affected",
"version": "24.04.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "h00die-gr3y"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.\u003cp\u003eThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\u003c/p\u003e"
}
],
"value": "In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-08T15:43:03.373Z",
"orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
"shortName": "Centreon"
},
"references": [
{
"tags": [
"release-notes"
],
"url": "https://github.com/centreon/centreon/releases"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5965-centreon-web-high-severity-5362"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "RCE via the backup feature available only to user with high privilege",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
"assignerShortName": "Centreon",
"cveId": "CVE-2025-5965",
"datePublished": "2026-01-05T10:06:05.494Z",
"dateReserved": "2025-06-10T08:14:47.529Z",
"dateUpdated": "2026-01-08T15:43:03.373Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-5965\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-01-05T20:01:00.415596Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-01-05T20:01:17.220Z\"}}], \"cna\": {\"title\": \"RCE via the backup feature available only to user with high privilege\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"h00die-gr3y\"}], \"impacts\": [{\"capecId\": \"CAPEC-88\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-88 OS Command Injection\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Centreon\", \"modules\": [\"Backup configuration in the administration setup\"], \"product\": \"Infra Monitoring\", \"versions\": [{\"status\": \"affected\", \"version\": \"25.10.0\", \"lessThan\": \"25.10.2\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"24.10.0\", \"lessThan\": \"24.10.15\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"24.04.0\", \"lessThan\": \"24.04.19\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://github.com/centreon/centreon/releases\", \"tags\": [\"release-notes\"]}, {\"url\": \"https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5965-centreon-web-high-severity-5362\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.\u003cp\u003eThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"bd4443e6-1eef-43f3-9886-25fc9ceeaae7\", \"shortName\": \"Centreon\", \"dateUpdated\": \"2026-01-08T15:43:03.373Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-5965\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-01-08T15:43:03.373Z\", \"dateReserved\": \"2025-06-10T08:14:47.529Z\", \"assignerOrgId\": \"bd4443e6-1eef-43f3-9886-25fc9ceeaae7\", \"datePublished\": \"2026-01-05T10:06:05.494Z\", \"assignerShortName\": \"Centreon\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…