CVE-2025-5825 (GCVE-0-2025-5825)
Vulnerability from cvelistv5
Published
2025-06-25 18:02
Modified
2025-06-25 18:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-1328 - Security Version Number Mutable to Older Versions
Summary
Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.
The specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354.
References
| ► | URL | Tags | |||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Autel | Autel MaxiCharger AC Wallbox Commercial |
Version: 1.36.00 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5825",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-25T18:17:50.082273Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T18:18:01.073Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Autel MaxiCharger AC Wallbox Commercial",
"vendor": "Autel",
"versions": [
{
"status": "affected",
"version": "1.36.00"
}
]
}
],
"dateAssigned": "2025-06-06T19:16:51.093Z",
"datePublic": "2025-06-11T17:27:15.633Z",
"descriptions": [
{
"lang": "en",
"value": "Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1328",
"description": "CWE-1328: Security Version Number Mutable to Older Versions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T18:02:18.293Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-25-344",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-25-344/"
}
],
"source": {
"lang": "en",
"value": "Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)"
},
"title": "Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2025-5825",
"datePublished": "2025-06-25T18:02:18.293Z",
"dateReserved": "2025-06-06T19:16:51.065Z",
"dateUpdated": "2025-06-25T18:18:01.073Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-5825\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-25T18:17:50.082273Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-25T18:17:52.731Z\"}}], \"cna\": {\"title\": \"Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability\", \"source\": {\"lang\": \"en\", \"value\": \"Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\"}}], \"affected\": [{\"vendor\": \"Autel\", \"product\": \"Autel MaxiCharger AC Wallbox Commercial\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.36.00\"}], \"defaultStatus\": \"unknown\"}], \"datePublic\": \"2025-06-11T17:27:15.633Z\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-25-344/\", \"name\": \"ZDI-25-344\", \"tags\": [\"x_research-advisory\"]}], \"dateAssigned\": \"2025-06-06T19:16:51.093Z\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\\n\\nThe specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1328\", \"description\": \"CWE-1328: Security Version Number Mutable to Older Versions\"}]}], \"providerMetadata\": {\"orgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"shortName\": \"zdi\", \"dateUpdated\": \"2025-06-25T18:02:18.293Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-5825\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-25T18:18:01.073Z\", \"dateReserved\": \"2025-06-06T19:16:51.065Z\", \"assignerOrgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"datePublished\": \"2025-06-25T18:02:18.293Z\", \"assignerShortName\": \"zdi\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…