CVE-2025-54892 (GCVE-0-2025-54892)
Vulnerability from cvelistv5
Published
2025-10-14 14:59
Modified
2025-10-15 13:12
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (SNMP traps group configuration modules)
allows Stored XSS by users with elevated privileges.
This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Centreon | Infra Monitoring |
Version: 24.10.0 < 24.10.13 Version: 24.04.0 < 24.04.18 Version: 23.10.0 < 23.10.28 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54892",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T16:05:09.568499Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T16:05:17.713Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"SNMP traps group configuration"
],
"product": "Infra Monitoring",
"vendor": "Centreon",
"versions": [
{
"lessThan": "24.10.13",
"status": "affected",
"version": "24.10.0",
"versionType": "custom"
},
{
"lessThan": "24.04.18",
"status": "affected",
"version": "24.04.0",
"versionType": "custom"
},
{
"lessThan": "23.10.28",
"status": "affected",
"version": "23.10.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Marcelo Queiroz"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (SNMP traps group configuration modules) \n\nallows Stored XSS by users with elevated privileges.\n\n\u003cp\u003eThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.\u003c/p\u003e"
}
],
"value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Centreon Infra Monitoring (SNMP traps group configuration modules) \n\nallows Stored XSS by users with elevated privileges.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
}
],
"impacts": [
{
"capecId": "CAPEC-592",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-592 Stored XSS"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-15T13:12:33.859Z",
"orgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
"shortName": "Centreon"
},
"references": [
{
"tags": [
"release-notes"
],
"url": "https://github.com/centreon/centreon/releases"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-54892-centreon-web-all-versions-medium-severity-5121"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "A user with elevated privileges can inject XSS in the SNMP traps group configuration page",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
"assignerShortName": "Centreon",
"cveId": "CVE-2025-54892",
"datePublished": "2025-10-14T14:59:10.681Z",
"dateReserved": "2025-07-31T18:22:28.420Z",
"dateUpdated": "2025-10-15T13:12:33.859Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…