CVE-2025-52947 (GCVE-0-2025-52947)
Vulnerability from cvelistv5
Published
2025-07-11 14:40
Modified
2025-07-11 15:25
CWE
  • CWE-755 - Improper Handling of Exceptional Conditions
Summary
An Improper Handling of Exceptional Conditions vulnerability in route processing of Juniper Networks Junos OS on specific end-of-life (EOL) ACX Series platforms allows an attacker to crash the Forwarding Engine Board (FEB) by flapping an interface, leading to a Denial of Service (DoS). On ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096 devices, FEB0 will crash when the primary path port of the L2 circuit IGP (Interior Gateway Protocol) on the local device goes down. This issue is seen only when 'hot-standby' mode is configured for the L2 circuit. This issue affects Junos OS on ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096:  * all versions before 21.2R3-S9.
References
Impacted products
Vendor Product Version
Juniper Networks Junos OS Version: 0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-52947",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-11T15:25:03.681598Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-11T15:25:08.865Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "ACX1000",
            "ACX1100",
            "ACX2000",
            "ACX2100",
            "ACX2200",
            "ACX4000",
            "ACX5048",
            "ACX5096"
          ],
          "product": "Junos OS",
          "vendor": "Juniper Networks",
          "versions": [
            {
              "lessThan": "21.2R3-S9",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "configurations": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "This issue only occurs when an L2 circuit is configured for hot-standby.\u0026nbsp; For example:\u003cbr\u003e\u003cbr\u003e\u003ctt\u003e[protocols l2circuit neighbor x.x.x.x interface \u0026lt;intf\u0026gt; backup-neighbor x.x.x.x hot-standby]\u003c/tt\u003e"
            }
          ],
          "value": "This issue only occurs when an L2 circuit is configured for hot-standby.\u00a0 For example:\n\n[protocols l2circuit neighbor x.x.x.x interface \u003cintf\u003e backup-neighbor x.x.x.x hot-standby]"
        }
      ],
      "datePublic": "2025-07-09T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Improper Handling of Exceptional Conditions vulnerability in route processing of Juniper Networks Junos OS on specific end-of-life (EOL) ACX Series platforms allows an attacker to crash the Forwarding Engine Board (FEB) by flapping an interface, leading to a Denial of Service (DoS).\u003cbr\u003e\u003cbr\u003eOn\u0026nbsp;ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096 devices, FEB0 will crash when the primary path port of the L2 circuit IGP (Interior Gateway Protocol) on the local device goes down. This issue is seen only when \u0027hot-standby\u0027 mode is configured for the L2 circuit.\u003cbr\u003e\u003cbr\u003e\u003cp\u003eThis issue affects Junos OS on ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096:\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eall versions before 21.2R3-S9.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "An Improper Handling of Exceptional Conditions vulnerability in route processing of Juniper Networks Junos OS on specific end-of-life (EOL) ACX Series platforms allows an attacker to crash the Forwarding Engine Board (FEB) by flapping an interface, leading to a Denial of Service (DoS).\n\nOn\u00a0ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096 devices, FEB0 will crash when the primary path port of the L2 circuit IGP (Interior Gateway Protocol) on the local device goes down. This issue is seen only when \u0027hot-standby\u0027 mode is configured for the L2 circuit.\n\nThis issue affects Junos OS on ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096:\u00a0\n\n\n\n  *  all versions before 21.2R3-S9."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
            }
          ],
          "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "AUTOMATIC",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "GREEN",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/R:A/RE:M/U:Green",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "MODERATE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-755",
              "description": "CWE-755 Improper Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-11T14:40:14.792Z",
        "orgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
        "shortName": "juniper"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://supportportal.juniper.net/JSA100051"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The following software releases have been updated to resolve this specific issue: 21.2R3-S9.\u003cbr\u003e\u003cbr\u003eNote: Support for the ACX2k Series ended with Junos OS 21.2."
            }
          ],
          "value": "The following software releases have been updated to resolve this specific issue: 21.2R3-S9.\n\nNote: Support for the ACX2k Series ended with Junos OS 21.2."
        }
      ],
      "source": {
        "advisory": "JSA100051",
        "defect": [
          "1840825"
        ],
        "discovery": "USER"
      },
      "title": "Junos OS: ACX Series: When \u0027hot-standby\u0027 mode is configured for an L2 circuit, interface flap causes the FEB to crash",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "There are no known workarounds for this issue."
            }
          ],
          "value": "There are no known workarounds for this issue."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
    "assignerShortName": "juniper",
    "cveId": "CVE-2025-52947",
    "datePublished": "2025-07-11T14:40:14.792Z",
    "dateReserved": "2025-06-23T13:16:01.408Z",
    "dateUpdated": "2025-07-11T15:25:08.865Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-52947\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-07-11T15:25:03.681598Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-07-11T15:25:06.197Z\"}}], \"cna\": {\"title\": \"Junos OS: ACX Series: When \u0027hot-standby\u0027 mode is configured for an L2 circuit, interface flap causes the FEB to crash\", \"source\": {\"defect\": [\"1840825\"], \"advisory\": \"JSA100051\", \"discovery\": \"USER\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.5, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"AUTOMATIC\", \"baseScore\": 7.1, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/R:A/RE:M/U:Green\", \"providerUrgency\": \"GREEN\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"LOW\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"MODERATE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Juniper Networks\", \"product\": \"Junos OS\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"21.2R3-S9\", \"versionType\": \"semver\"}], \"platforms\": [\"ACX1000\", \"ACX1100\", \"ACX2000\", \"ACX2100\", \"ACX2200\", \"ACX4000\", \"ACX5048\", \"ACX5096\"], \"defaultStatus\": \"unaffected\"}], \"exploits\": [{\"lang\": \"en\", \"value\": \"Juniper SIRT is not aware of any malicious exploitation of this vulnerability.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Juniper SIRT is not aware of any malicious exploitation of this vulnerability.\", \"base64\": false}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"The following software releases have been updated to resolve this specific issue: 21.2R3-S9.\\n\\nNote: Support for the ACX2k Series ended with Junos OS 21.2.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The following software releases have been updated to resolve this specific issue: 21.2R3-S9.\u003cbr\u003e\u003cbr\u003eNote: Support for the ACX2k Series ended with Junos OS 21.2.\", \"base64\": false}]}], \"datePublic\": \"2025-07-09T16:00:00.000Z\", \"references\": [{\"url\": \"https://supportportal.juniper.net/JSA100051\", \"tags\": [\"vendor-advisory\"]}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"There are no known workarounds for this issue.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"There are no known workarounds for this issue.\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An Improper Handling of Exceptional Conditions vulnerability in route processing of Juniper Networks Junos OS on specific end-of-life (EOL) ACX Series platforms allows an attacker to crash the Forwarding Engine Board (FEB) by flapping an interface, leading to a Denial of Service (DoS).\\n\\nOn\\u00a0ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096 devices, FEB0 will crash when the primary path port of the L2 circuit IGP (Interior Gateway Protocol) on the local device goes down. This issue is seen only when \u0027hot-standby\u0027 mode is configured for the L2 circuit.\\n\\nThis issue affects Junos OS on ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096:\\u00a0\\n\\n\\n\\n  *  all versions before 21.2R3-S9.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"An Improper Handling of Exceptional Conditions vulnerability in route processing of Juniper Networks Junos OS on specific end-of-life (EOL) ACX Series platforms allows an attacker to crash the Forwarding Engine Board (FEB) by flapping an interface, leading to a Denial of Service (DoS).\u003cbr\u003e\u003cbr\u003eOn\u0026nbsp;ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096 devices, FEB0 will crash when the primary path port of the L2 circuit IGP (Interior Gateway Protocol) on the local device goes down. This issue is seen only when \u0027hot-standby\u0027 mode is configured for the L2 circuit.\u003cbr\u003e\u003cbr\u003e\u003cp\u003eThis issue affects Junos OS on ACX1000, ACX1100, ACX2000, ACX2100, ACX2200, ACX4000, ACX5048, and ACX5096:\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eall versions before 21.2R3-S9.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-755\", \"description\": \"CWE-755 Improper Handling of Exceptional Conditions\"}]}], \"configurations\": [{\"lang\": \"en\", \"value\": \"This issue only occurs when an L2 circuit is configured for hot-standby.\\u00a0 For example:\\n\\n[protocols l2circuit neighbor x.x.x.x interface \u003cintf\u003e backup-neighbor x.x.x.x hot-standby]\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"This issue only occurs when an L2 circuit is configured for hot-standby.\u0026nbsp; For example:\u003cbr\u003e\u003cbr\u003e\u003ctt\u003e[protocols l2circuit neighbor x.x.x.x interface \u0026lt;intf\u0026gt; backup-neighbor x.x.x.x hot-standby]\u003c/tt\u003e\", \"base64\": false}]}], \"providerMetadata\": {\"orgId\": \"8cbe9d5a-a066-4c94-8978-4b15efeae968\", \"shortName\": \"juniper\", \"dateUpdated\": \"2025-07-11T14:40:14.792Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-52947\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-07-11T15:25:08.865Z\", \"dateReserved\": \"2025-06-23T13:16:01.408Z\", \"assignerOrgId\": \"8cbe9d5a-a066-4c94-8978-4b15efeae968\", \"datePublished\": \"2025-07-11T14:40:14.792Z\", \"assignerShortName\": \"juniper\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…