CVE-2025-43937 (GCVE-0-2025-43937)
Vulnerability from cvelistv5
Published
2026-04-16 18:03
Modified
2026-04-16 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Summary
Dell PowerScale OneFS, versions prior to 9.12.0.0, contains an insertion of sensitive information into log file vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the vulnerable application with privileges of the compromised account.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerScale OneFS |
Version: 9.5.0.0 ≤ Version: 0 ≤ Version: 9.7.0.0 ≤ Version: 9.5.0.0 ≤ |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-43937",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-16T18:51:17.818973Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-16T18:51:41.562Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale OneFS",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.10.1.3",
"status": "affected",
"version": "9.5.0.0",
"versionType": "semver"
},
{
"lessThan": "9.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "9.7.1.9",
"status": "affected",
"version": "9.7.0.0",
"versionType": "semver"
},
{
"lessThan": "9.5.1.5",
"status": "affected",
"version": "9.5.0.0",
"versionType": "semver"
}
]
}
],
"datePublic": "2025-10-01T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale OneFS, versions prior to 9.12.0.0, contains an insertion of sensitive information into log file vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the vulnerable application with privileges of the compromised account."
}
],
"value": "Dell PowerScale OneFS, versions prior to 9.12.0.0, contains an insertion of sensitive information into log file vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the vulnerable application with privileges of the compromised account."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-16T18:03:08.750Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000376214/dsa-2025-347-security-update-for-dell-powerscale-onefs-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2025-43937",
"datePublished": "2026-04-16T18:03:08.750Z",
"dateReserved": "2025-04-20T05:04:01.415Z",
"dateUpdated": "2026-04-16T18:51:41.562Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-43937\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-04-16T18:51:17.818973Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-04-16T18:51:21.123Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.6, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"PowerScale OneFS\", \"versions\": [{\"status\": \"affected\", \"version\": \"9.5.0.0\", \"lessThan\": \"9.10.1.3\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"9.12.0.0\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"9.7.0.0\", \"lessThan\": \"9.7.1.9\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"9.5.0.0\", \"lessThan\": \"9.5.1.5\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2025-10-01T17:00:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000376214/dsa-2025-347-security-update-for-dell-powerscale-onefs-multiple-vulnerabilities\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.1\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell PowerScale OneFS, versions prior to 9.12.0.0, contains an insertion of sensitive information into log file vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the vulnerable application with privileges of the compromised account.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell PowerScale OneFS, versions prior to 9.12.0.0, contains an insertion of sensitive information into log file vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the vulnerable application with privileges of the compromised account.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-532\", \"description\": \"CWE-532: Insertion of Sensitive Information into Log File\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2026-04-16T18:03:08.750Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-43937\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-04-16T18:51:41.562Z\", \"dateReserved\": \"2025-04-20T05:04:01.415Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2026-04-16T18:03:08.750Z\", \"assignerShortName\": \"dell\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.