CVE-2025-4139 (GCVE-0-2025-4139)
Vulnerability from cvelistv5
Published
2025-04-30 20:31
Modified
2025-04-30 20:35
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
Summary
A vulnerability classified as critical was found in Netgear EX6120 1.0.0.68. Affected by this vulnerability is the function fwAcosCgiInbound. The manipulation of the argument host leads to buffer overflow. The attack can be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-4139",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-30T20:35:15.404496Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-30T20:35:31.481Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX6120",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "1.0.0.68"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "54357 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Netgear EX6120 1.0.0.68. Affected by this vulnerability is the function fwAcosCgiInbound. The manipulation of the argument host leads to buffer overflow. The attack can be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Netgear EX6120 1.0.0.68 wurde eine kritische Schwachstelle entdeckt. Das betrifft die Funktion fwAcosCgiInbound. Mittels Manipulieren des Arguments host mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-30T20:31:04.150Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-306631 | Netgear EX6120 fwAcosCgiInbound buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.306631"
},
{
"name": "VDB-306631 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.306631"
},
{
"name": "Submit #560785 | Netgear EX6120 1.0.0.68 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.560785"
},
{
"tags": [
"related"
],
"url": "https://github.com/jylsec/vuldb/blob/main/Netgear/netgear_ex6120/Buffer_overflow-fwAcosCgiInbound-port_end/README.md"
},
{
"tags": [
"product"
],
"url": "https://www.netgear.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-04-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-04-30T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-04-30T16:12:17.000Z",
"value": "VulDB entry last update"
}
],
"title": "Netgear EX6120 fwAcosCgiInbound buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-4139",
"datePublished": "2025-04-30T20:31:04.150Z",
"dateReserved": "2025-04-30T14:07:12.261Z",
"dateUpdated": "2025-04-30T20:35:31.481Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-4139\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-30T20:35:15.404496Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-30T20:35:24.784Z\"}}], \"cna\": {\"title\": \"Netgear EX6120 fwAcosCgiInbound buffer overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"54357 (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\"}}], \"affected\": [{\"vendor\": \"Netgear\", \"product\": \"EX6120\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.0.68\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-04-30T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-04-30T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-04-30T16:12:17.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.306631\", \"name\": \"VDB-306631 | Netgear EX6120 fwAcosCgiInbound buffer overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.306631\", \"name\": \"VDB-306631 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.560785\", \"name\": \"Submit #560785 | Netgear EX6120 1.0.0.68 Buffer Overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/jylsec/vuldb/blob/main/Netgear/netgear_ex6120/Buffer_overflow-fwAcosCgiInbound-port_end/README.md\", \"tags\": [\"related\"]}, {\"url\": \"https://www.netgear.com/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability classified as critical was found in Netgear EX6120 1.0.0.68. Affected by this vulnerability is the function fwAcosCgiInbound. The manipulation of the argument host leads to buffer overflow. The attack can be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"In Netgear EX6120 1.0.0.68 wurde eine kritische Schwachstelle entdeckt. Das betrifft die Funktion fwAcosCgiInbound. Mittels Manipulieren des Arguments host mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \\u00fcber das Netzwerk angegangen werden.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-120\", \"description\": \"Buffer Overflow\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-119\", \"description\": \"Memory Corruption\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-04-30T20:31:04.150Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-4139\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-30T20:35:31.481Z\", \"dateReserved\": \"2025-04-30T14:07:12.261Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-04-30T20:31:04.150Z\", \"assignerShortName\": \"VulDB\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…