CVE-2025-2884 (GCVE-0-2025-2884)
Vulnerability from cvelistv5
Published
2025-06-10 17:29
Modified
2026-04-14 08:58
Severity ?
VLAI Severity ?
EPSS score ?
Summary
TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Trusted Computing Group | TPM2.0 |
Version: 0 < 1.83 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-06-10T19:02:29.811Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html"
},
{
"url": "https://www.kb.cert.org/vuls/id/282450"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-2884",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-13T01:41:10.489446Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-13T01:46:13.802Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-32A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-39A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-56A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V32.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-59A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V32.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC MD-57A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V30.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-32A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-39A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-39A PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC RW-528A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V34.01.02",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC RW-548A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V34.01.02",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T08:58:06.200Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-628843.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "TPM2.0",
"vendor": "Trusted Computing Group",
"versions": [
{
"lessThan": "1.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "TCG TPM2.0 Reference implementation\u0027s CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key\u0027s algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0"
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2884",
"selections": [
{
"name": "Exploitation",
"namespace": "ssvc",
"values": [
"none"
],
"version": "1.0.0"
},
{
"name": "Automatable",
"namespace": "ssvc",
"values": [
"no"
],
"version": "2.0.0"
},
{
"name": "Technical Impact",
"namespace": "ssvc",
"values": [
"partial"
],
"version": "1.0.0"
},
{
"name": "Mission \u0026 Well-being",
"namespace": "ssvc",
"values": [
"medium"
],
"version": "1.0.0"
}
],
"timestamp": "2025-06-13T17:22:30.584Z"
},
"type": "ssvcV1_0_1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-125 Out-of-bounds Read",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-13T18:22:21.856Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://trustedcomputinggroup.org/about/security/"
},
{
"name": "TPM2.0 Errata",
"url": "https://trustedcomputinggroup.org/wp-content/uploads/TPM2.0-Library-Spec-v1.83-Errata_v1_pub.pdf"
},
{
"name": "Vendor Advisory",
"url": "https://trustedcomputinggroup.org/wp-content/uploads/VRT0009-Advisory-FINAL.pdf"
},
{
"name": "Vendor Patch",
"url": "https://github.com/stefanberger/libtpms/commit/04b2d8e9afc0a9b6bffe562a23e58c0de11532d1"
},
{
"name": "Related CVE",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-49133"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation",
"x_generator": {
"engine": "VINCE 3.0.20",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2025-2884"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2025-2884",
"datePublished": "2025-06-10T17:29:19.463Z",
"dateReserved": "2025-03-27T21:01:41.908Z",
"dateUpdated": "2026-04-14T08:58:06.200Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html\"}, {\"url\": \"https://www.kb.cert.org/vuls/id/282450\"}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2025-06-10T19:02:29.811Z\"}}, {\"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SIMATIC CN 4100\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Field PG M5\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Field PG M6\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC BX-32A\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V29.01.09\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC BX-39A\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V29.01.09\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC BX-56A\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V32.01.09\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC BX-59A\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V32.01.09\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC MD-57A\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V30.01.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC PX-32A\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V29.01.09\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC PX-39A\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V29.01.09\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC PX-39A PRO\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V29.01.09\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC RW-528A\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V34.01.02\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC RW-548A\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V34.01.02\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC227E\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC277E\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC427E\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V21.01.20\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC477E\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V21.01.20\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC477E PRO\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V21.01.20\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC627E\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC647E\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC677E\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC847E\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC ITP1000\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPLUS IPC427E\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V21.01.20\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"x_adpType\": \"supplier\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-628843.html\"}], \"providerMetadata\": {\"orgId\": \"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e\", \"shortName\": \"siemens-SADP\", \"dateUpdated\": \"2026-04-14T08:58:06.200Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.6, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-2884\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-13T01:41:10.489446Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-125\", \"description\": \"CWE-125 Out-of-bounds Read\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-11T15:04:54.186Z\"}}], \"cna\": {\"title\": \"Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation\", \"source\": {\"discovery\": \"INTERNAL\"}, \"metrics\": [{\"other\": {\"type\": \"ssvcV1_0_1\", \"content\": {\"id\": \"CVE-2025-2884\", \"timestamp\": \"2025-06-13T17:22:30.584Z\", \"selections\": [{\"name\": \"Exploitation\", \"values\": [\"none\"], \"version\": \"1.0.0\", \"namespace\": \"ssvc\"}, {\"name\": \"Automatable\", \"values\": [\"no\"], \"version\": \"2.0.0\", \"namespace\": \"ssvc\"}, {\"name\": \"Technical Impact\", \"values\": [\"partial\"], \"version\": \"1.0.0\", \"namespace\": \"ssvc\"}, {\"name\": \"Mission \u0026 Well-being\", \"values\": [\"medium\"], \"version\": \"1.0.0\", \"namespace\": \"ssvc\"}]}}}], \"affected\": [{\"vendor\": \"Trusted Computing Group\", \"product\": \"TPM2.0\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.83\", \"versionType\": \"custom\"}]}], \"references\": [{\"url\": \"https://trustedcomputinggroup.org/about/security/\"}, {\"url\": \"https://trustedcomputinggroup.org/wp-content/uploads/TPM2.0-Library-Spec-v1.83-Errata_v1_pub.pdf\", \"name\": \"TPM2.0 Errata\"}, {\"url\": \"https://trustedcomputinggroup.org/wp-content/uploads/VRT0009-Advisory-FINAL.pdf\", \"name\": \"Vendor Advisory\"}, {\"url\": \"https://github.com/stefanberger/libtpms/commit/04b2d8e9afc0a9b6bffe562a23e58c0de11532d1\", \"name\": \"Vendor Patch\"}, {\"url\": \"https://www.cve.org/CVERecord?id=CVE-2025-49133\", \"name\": \"Related CVE\"}], \"x_generator\": {\"env\": \"prod\", \"engine\": \"VINCE 3.0.20\", \"origin\": \"https://cveawg.mitre.org/api/cve/CVE-2025-2884\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"TCG TPM2.0 Reference implementation\u0027s CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key\u0027s algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"description\": \"CWE-125 Out-of-bounds Read\"}]}], \"providerMetadata\": {\"orgId\": \"37e5125f-f79b-445b-8fad-9564f167944b\", \"shortName\": \"certcc\", \"dateUpdated\": \"2025-06-13T18:22:21.856Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-2884\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-04-14T08:58:06.200Z\", \"dateReserved\": \"2025-03-27T21:01:41.908Z\", \"assignerOrgId\": \"37e5125f-f79b-445b-8fad-9564f167944b\", \"datePublished\": \"2025-06-10T17:29:19.463Z\", \"assignerShortName\": \"certcc\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…