CVE-2025-12772 (GCVE-0-2025-12772)
Vulnerability from cvelistv5
Published
2026-02-02 22:41
Modified
2026-02-04 16:53
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Summary
Brocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs. When OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password.
Impacted products
Vendor Product Version
Brocade SANnav Version: before 2.4.0b
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12772",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-04T15:46:39.820278Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-04T16:53:20.826Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before 2.4.0b"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eBrocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs.\u003c/span\u003e\u003c/p\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eWhen OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password.\u003c/span\u003e\u003cspan style=\"background-color: transparent;\"\u003e\u0026nbsp;\u003c/span\u003e\u003c/p\u003e"
            }
          ],
          "value": "Brocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs.\n\nWhen OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-03T01:59:41.935Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/36846"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Plaintext Switch admin login password is seen in Brocade SANnav support save",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2025-12772",
    "datePublished": "2026-02-02T22:41:13.921Z",
    "dateReserved": "2025-11-05T20:05:22.781Z",
    "dateUpdated": "2026-02-04T16:53:20.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-12772\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-02-04T15:46:39.820278Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-02-04T15:46:40.566Z\"}}], \"cna\": {\"title\": \"Plaintext Switch admin login password is seen in Brocade SANnav support save\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-37\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-37 Retrieve Embedded Sensitive Data\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.5, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"PASSIVE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"HIGH\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Brocade\", \"product\": \"SANnav\", \"versions\": [{\"status\": \"affected\", \"version\": \"before 2.4.0b\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/36846\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.5.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Brocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs.\\n\\nWhen OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003e\u003cspan style=\\\"background-color: transparent;\\\"\u003eBrocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs.\u003c/span\u003e\u003c/p\u003e\u003cp\u003e\u003cspan style=\\\"background-color: transparent;\\\"\u003eWhen OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password.\u003c/span\u003e\u003cspan style=\\\"background-color: transparent;\\\"\u003e\u0026nbsp;\u003c/span\u003e\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-312\", \"description\": \"CWE-312 Cleartext Storage of Sensitive Information\"}]}], \"providerMetadata\": {\"orgId\": \"87b297d7-335e-4844-9551-11b97995a791\", \"shortName\": \"brocade\", \"dateUpdated\": \"2026-02-03T01:59:41.935Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-12772\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-02-04T16:53:20.826Z\", \"dateReserved\": \"2025-11-05T20:05:22.781Z\", \"assignerOrgId\": \"87b297d7-335e-4844-9551-11b97995a791\", \"datePublished\": \"2026-02-02T22:41:13.921Z\", \"assignerShortName\": \"brocade\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…