CVE-2025-11407 (GCVE-0-2025-11407)
Vulnerability from cvelistv5
Published
2025-10-07 20:02
Modified
2025-10-07 20:33
Severity ?
2.1 (Low) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RC:R
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RC:R
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RC:R
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RC:R
VLAI Severity ?
EPSS score ?
Summary
A weakness has been identified in D-Link DI-7001 MINI 24.04.18B1. Impacted is an unknown function of the file /upgrade_filter.asp. This manipulation of the argument path causes os command injection. The attack may be initiated remotely. The exploit has been made available to the public and could be exploited.
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DI-7001 MINI |
Version: 24.04.18B1 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-11407",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-07T20:31:14.679154Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-07T20:33:12.045Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DI-7001 MINI",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "24.04.18B1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Yun Zhang (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in D-Link DI-7001 MINI 24.04.18B1. Impacted is an unknown function of the file /upgrade_filter.asp. This manipulation of the argument path causes os command injection. The attack may be initiated remotely. The exploit has been made available to the public and could be exploited."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in D-Link DI-7001 MINI 24.04.18B1 gefunden. Hierbei geht es um eine nicht exakt ausgemachte Funktion der Datei /upgrade_filter.asp. Durch Beeinflussen des Arguments path mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Die Ausnutzung wurde ver\u00f6ffentlicht und kann verwendet werden."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-07T20:02:05.836Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-327344 | D-Link DI-7001 MINI upgrade_filter.asp os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.327344"
},
{
"name": "VDB-327344 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.327344"
},
{
"name": "Submit #665471 | D-Link DI-7001MINI-8G Gateway V24.04.18B1 Remote Code Execution",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.665471"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/DavCloudz/cve/issues/4"
},
{
"tags": [
"product"
],
"url": "https://www.dlink.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-10-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-10-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-10-07T09:28:40.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DI-7001 MINI upgrade_filter.asp os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-11407",
"datePublished": "2025-10-07T20:02:05.836Z",
"dateReserved": "2025-10-07T07:23:37.593Z",
"dateUpdated": "2025-10-07T20:33:12.045Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-11407\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-10-07T20:31:14.679154Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-10-07T20:33:07.798Z\"}}], \"cna\": {\"title\": \"D-Link DI-7001 MINI upgrade_filter.asp os command injection\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"Yun Zhang (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 6.5, \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"vendor\": \"D-Link\", \"product\": \"DI-7001 MINI\", \"versions\": [{\"status\": \"affected\", \"version\": \"24.04.18B1\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-10-07T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-10-07T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-10-07T09:28:40.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.327344\", \"name\": \"VDB-327344 | D-Link DI-7001 MINI upgrade_filter.asp os command injection\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.327344\", \"name\": \"VDB-327344 | CTI Indicators (IOB, IOC, TTP, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.665471\", \"name\": \"Submit #665471 | D-Link DI-7001MINI-8G Gateway V24.04.18B1 Remote Code Execution\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/DavCloudz/cve/issues/4\", \"tags\": [\"exploit\", \"issue-tracking\"]}, {\"url\": \"https://www.dlink.com/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A weakness has been identified in D-Link DI-7001 MINI 24.04.18B1. Impacted is an unknown function of the file /upgrade_filter.asp. This manipulation of the argument path causes os command injection. The attack may be initiated remotely. The exploit has been made available to the public and could be exploited.\"}, {\"lang\": \"de\", \"value\": \"Eine Schwachstelle wurde in D-Link DI-7001 MINI 24.04.18B1 gefunden. Hierbei geht es um eine nicht exakt ausgemachte Funktion der Datei /upgrade_filter.asp. Durch Beeinflussen des Arguments path mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \\u00fcber das Netzwerk erfolgen. Die Ausnutzung wurde ver\\u00f6ffentlicht und kann verwendet werden.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"OS Command Injection\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"Command Injection\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-10-07T20:02:05.836Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-11407\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-07T20:33:12.045Z\", \"dateReserved\": \"2025-10-07T07:23:37.593Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-10-07T20:02:05.836Z\", \"assignerShortName\": \"VulDB\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…